Process Sensor AP-C30W Keyence
Process Sensor AP-C30W Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

AP-C30W Keyence Process Sensor

Manufacturer

Keyence

Country

Japan

Name

AP-C30W

Type

Process Sensor

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications AP-C30W

If you are pursuing Keyence AP-C30W , contact FAMAGA, the world's influential vendor of machine made equipment. Our company has functioned for more than ten years - these are years of experience, which are expressed in the quality of products and special attention to each purchaser. We appreciate everyone, who joined with us - therefore, our regular buyers procure the most favorable purchase conditions and discounts on the industrial equipment market. At this moment, there are more than 4000 such buyers, and we constantly sign new agreements. More than 650 transactions are made per day, because FAMAGA operates all over the world . A well-elaborated logistics connection and a partnership network allow us to send our goods anywhere in the world as soon as possible without discrediting product quality.

A special source of honor for FAMAGA is its staff members, each of whom contributes to our work. We invite into our team only professionals, who already have experience in the field of industrial equipment.

All spare parts from FAMAGA are assured - we are responsible for the outcome of our work. At the moment, more than 10 million units of products have been shipped, and this number is rising every day. We are proud that customers choose FAMAGA again and again, and we are eager to make more advanced and technologically developed industrial equipment so as not to lower the bar.

To ask a question or place an order, call us by phone or write to the online chat on our official website. You can also send a list of the required equipment to the email of our company - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.

Features AP-C30W

Main Unit, Compound-pressure Type, 101.3 to -101.3 kPa, NPN
Model AP-C30W
Type Multi range
Rated pressure Negative pressure mode: 0 to -101.3 kPa Positive pressure mode: 0 to -100.0kPa Compound pressure mode: +101.3 to -101.3kPa
Fluid type Air or non-corrosive gases
Type of pressure Gauge pressure
Display 3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm), Display cycle: 10 times/s
Operation indicator Red LED x 2 (corresponding to control output 1 and 2)
Power consumption Normal 12 V: 720 mW (60 mA) or less, 24 V: 960 mW (40 mA) or less*1
Display resolution Multi range: Negative/Positive 0.1 kPa, Compound 0.2 kPa
Display temperature characteristic ±1 % of F.S. max.
Hysteresis Variable (Standard: 0.5 % of F.S.)*2
Response time (Chattering prevention function) 2.5, 5, 100, or 500 ms (selectable)
I/O Analogue output 1 to 5 V with load impedance of 1 k? max. (or zero-shift input selectable)
Zero-shift input Input time: 2 ms or more. (or analog output selectable)
Control output NPN open collector 100 mA max. (at 40 V or below) with max. residual voltage of 1 V, 2 outputs (NO or NC selectable)
Pressure port Rc (PT) 1/8 180 ° rotation
Rating Power voltage 12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less
Power consumption Eco mode 12 V: 480 mW (40 mA) or less, 24 V: 720 mW (30 mA) or less*1
Environmental resistance Pressure resistance 500 kPa
Ambient temperature 0 to +50 °C (No freezing)
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Material Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate, Pressure port: Zinc die-casting
Accessories Power supply cord (2-m with connector)
Weight Approx. 30 g (without cable) /Approx. 85 g (with 2-m cable)
*1 Excluding the current for analog output Including the current for the sensor head *2 A standard of 0.2 % of FS applies while in focus mode.