Mounting bracket LS-7001 Keyence
Mounting bracket LS-7001 Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

LS-7001 Keyence Mounting bracket

Manufacturer

Keyence

Country

Japan

Name

LS-7001

Type

Mounting bracket

Description

STEUERGERAET STEUERGERÄT CCD/GAN-LED-MIKROMETER, 21588

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications LS-7001

Keyence HIGH-ACCURACYMICROMETER

Features LS-7001

Controller, without Monitor Function
Model LS-7001*1
Type Standard
No. of connectable sensor heads 2 (fully compatible for all head types except monitor (M) models)
Display Measurement display Main display: 7-segment red LED (Character height: 20.3 mm) Sub-display: 7-segment red LED (Character height: 9.9 mm) x 3
Minimum display unit 0.01 to 100 µm (7-level selectable)
Display range ±99.99999 to 9,999.9 mm (Linked to minimum display unit setting, mm/µm selectable)
Measurement position monitor 7-level display with a red LED
Tolerance check output display Green LED (GO), Red LED x 2 (HI, LO)
Input terminal block Synchronous 1, 2 input Non-voltage input for OUT1
Auto-zero 1, 2 input
Reset 1, 2 input
Statistics 1, 2 input -
Program selection input Non-voltage input x 4 inputs
Output terminal Analogue voltage output ±10 V x 2 outputs
Alarm output NPN open-collector output (N.C.)
Total judgment output NPN open-collector output for OUT1
Comparator ready output
Strobe 1, 2 output
Connector I/O SUB mode Statistical processing output -
Function output Selectable from focus, area check, and differential, NPN open-collector output x 2 outputs*2
5-level comparator output NPN open-collector output for OUT2*2
Comparator ready output
Strobe output
BCD mode BCD output Measurement data output (Sign + 7 digits), OUT1/OUT2 selectable, NPN open-collector output*2
BCD selection output NPN open-collector output*2
BCD selection input Non-voltage input*2
Statistical processing input -
Synchronous input Non-voltage input for OUT2
Reset input
Auto-zero input
Interface RS-232C Measurement data output and control I/O, printer (Baud rate can be selected up to 115,200 bps.)
Video output -
Major functions Simultaneous measurement, Area designation, Calculation, Averaging, Calibration, 16-program memory, Measurement modes, Auto-zero, Print-out, Abnormal value elimination, Transparent object measurement, Mutual interference prevention, etc.
Rating Power voltage 24 VDC ±10 %*3
Power consumption 0.7 A max.*3
Environmental resistance Enclosure rating IP64 (Panel surface only)
Ambient temperature 0 to +40 °C
Relative humidity 35 to 85 % RH (No condensation)
Weight Approx. 820 g
*1 The rating of the NPN open-collector inside the terminal block is: 100 mA max. (40 V max.), residual voltage of 0.5 V max. The rating of the NPN open-collector inside the connector I/O is: 30 mA max. (30 V max.), residual voltage of 0.5 V max. The rating of non-voltage input is: ON voltage of 1 V max., OFF current of 0.6 mA max. *2 Either SUB mode or BCD mode can be selected. *3 AC power supply can be used when the LS-S11 (AC power supply stand) is connected.