We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are seeking Keyence LJ-V7300B , connect FAMAGA, the world's major retailer of industrialized equipment. Our company has advanced for more than ten years - these are ages of experience, which are depicted in the quality of merchandises and private attention to each customer. We understand everyone, who liased with us - therefore, our regular consumers bring in the most convenient purchase terms and discounts on the industrial equipment market. Today, there are more than 4000 such consumers, and we constantly make new agreements. More than 650 affairs are settled per day, because FAMAGA operates all over the world Germany, United Kingdom, Poland, France, El Salvador, Jamaica, Guyana, Qatar, Fiji, Brunei, Papua New Guinea, Algeria, Brazil, Kyrgyzstan, Andorra, Mozambique, Bolivia, Egypt, Netherlands, Austria, Botswana, Mongolia, Greece, United States, Moldova, Denmark, Syria, Finland, Yemen, Samoa, Niger, Russia, Iraq, Croatia, Rwanda, South Sudan, Comoros, Albania, Zimbabwe, Estonia, Peru, Angola, Switzerland, Suriname, New Zealand, Malaysia, Mauritania. A well-built logistics link and a partnership network guide us to dispatch our items anywhere in the world on-time without disreputing product quality.
A specific source of dignity for FAMAGA is its team members, each of whom contributes to our work. We request into our team only specialists, who already have experience in the field of industrial equipment.
All merchandises from FAMAGA are verified - we are responsible for the outcome of our work. At the moment, more than 10 million units of products have been shipped, and this number is ascending every day. We are proud that consumers choose FAMAGA again and again, and we are happy to make more advanced and technologically developed industrial equipment so as not to lower the bar.
To get some advice or place an order, call us by phone or send a message to the online chat on our official website. You can also send a list of the required equipment to the email of our company - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
Model | LJ-V7300B | |
Mounting conditions | Diffuse reflection | |
Reference distance | 300 mm | |
Measurement range | Z-axis (height) | ±145 mm (F.S.=290 mm) |
X-axis (width) | NEAR side | 110 mm |
Reference distance | 180 mm | |
Far side | 240 mm | |
Light source | Type | Blue semiconductor laser |
Wavelength | 405 nm (visible beam) | |
Laser class | Class 2 Laser Product (IEC60825-1, FDA(CDRH) Part 1040.10*1) | |
Output | 4.8 mW | |
Spot size (reference distance) | Approx. 240 mm ? 610 µm | |
Repeatability | Z-axis (height) | 5 µm*2*3 |
X-axis (width) | 60 µm*2*4 | |
Linearity | Z-axis (height) | ±0.05 to ±0.15% of F.S.*5*6 |
Profile data interval | X-axis (width) | 300 µm |
Sampling cycle (trigger interval) | Top speed: 125 µs*7 | |
Temperature characteristics | 0.01% of F.S./°C | |
Environmental resistance | Enclosure rating | IP67 (IEC60529)*8 |
Ambient light | Incandescent lamp: 10,000 lux max.*9 | |
Ambient temperature | 0 to +45 °C*10 | |
Relative humidity | 20 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 3 hours in each of the X, Y, and Z directions | |
Shock resistance | 15 G/6 ms | |
Material | Aluminium | |
Weight | Approx. 1,000 g | |
*1 The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No. 50. *2 This value is from a case in which measurement has been performed with a reference distance with 4,096 times of averaging. *3 The measurement targets are KEYENCE standard targets. This value is from a case in which the average height of the default setting area has been measured in height mode. All other settings are default. *4 The measurement target is a pin gauge. This value is from a case in which the position of the intersection between the rounded surface of the pin gauge and the edge level has been measured in position mode. All other settings are default. *5 The measurement targets are KEYENCE standard targets. The profile data is from a case in which measurement has been performed with 64 times of smoothing and 8 times of averaging. All other settings are default. *6 The linearity will differ depending on the measurement area. *7 Sampling frequency depends on the setting of measurement range, binning and parallel imaging. *8 This value is from a case in which the sensor head cable (CB-B*) or extension cable (CB-B*E) has been connected. *9 This is the illuminance for the light-receiving surface of the sensor head during white paper measurement when light has been shined onto the white paper. *10 The sensor head must be mounted on a metal plate for use. |