We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are inspecting Keyence LK-2001 , connect FAMAGA, the world's influential vendor of machine made equipment. Our company has functioned for more than ten years - these are years of experience, which are depicted in the quality of merchandises and particular attention to each purchaser. We understand everyone, who joined with us - therefore, our regular purchasers procure the most convenient purchase conditions and discounts on the industrial equipment market. At this moment, there are more than 4000 such purchasers, and we constantly arrange new agreements. More than 650 transactions are made per day, because FAMAGA operates all over the world Germany, United Kingdom, Sri Lanka, Jordan, Romania, The Bahamas, Tonga, Senegal, Slovenia, Zimbabwe, Panama, Finland, Switzerland, Togo, Mongolia, Serbia, Paraguay, El Salvador, Morocco, Egypt, Mexico, Poland, Albania, Fiji, Namibia, Seychelles, Argentina, Monaco, Russia, Kuwait, China, Eswatini, East Timor, Armenia, Qatar, Bosnia and Herzegovina, Indonesia, Estonia, Afghanistan, Bulgaria, Samoa, Kyrgyzstan, Djibouti, Kiribati, Mauritania, Iraq. A well-shaped logistics connection and a partnership network allow us to ship our goods anywhere in the world as soon as possible without damaging product quality.
A special source of repute for FAMAGA is its personnel, each of whom contributes to our work. We call into our team only professionals, who already have experience in the field of industrial equipment.
All spare parts from FAMAGA are affirmed - we are responsible for the outcome of our work. At the moment, more than 10 million units of products have been shipped, and this number is amounting every day. We are proud that customers choose FAMAGA again and again, and we are glad to make more advanced and technologically developed industrial equipment so as not to lower the bar.
To request or place an order, call us by phone or write to the online chat on our official website. You can also send a list of the required equipment to the email of our company - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
Model | LK-2001 | |
Type | Amplifier unit, High-precision Controller | |
Measurement mode | ? | |
Reference distance | 30 mm | |
Measuring range | ±5 mm | |
Light source | Type | Visible red semiconductor laser |
Wavelength | 670 nm | |
Output | 0.95 mW | |
Laser Class | FDA (CDRH) 21CFR Part 1040.10 | Class 2 Laser Product |
Laser Class | IEC 60825-1 | |
Spot diameter (at standard distance) | Approx. 30 µm, Approx. 30 x 850 µm | |
Linearity | ±0.1% of F.S. *1 | |
Repeatability | 1 µm*2 | |
Analogue output | Output voltage | ±5 V (1 µm/mV)*3 |
Impedance | 100 ? | |
Output current | 4 to 20 mA (Applicable load: 350 ? max.) | |
Alarm output | NPN: 100 mA max. (40 V max.) (N.C.), Residual voltage: 1 V max. | |
Sampling cycle | 512 µs | |
Other functions | Auto-zero, analog output holding when an alarm occurs, gain switching, response switching, span and shift adjustment of mirror surface measurement mode, changing the sampling cycle | |
Temperature characteristics | 0.01% of F.S./°C | |
Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less |
Maximum current consumption | 400 mA max. | |
Environmental resistance | Enclosure rating | IP67 |
Ambient light | Incandescent or fl uorescent lamp: 10,000 lux max. | |
Ambient temperature | 0 to +50 °C (No condensation) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Material | Polycarbonate | |
Weight | Approx. 515 g (including cable) | |
*1 Linearity was obtained using KEYENCE's standard target (Zirconia block gauge: LK-031/036, LK-081/086, LK-011, White ceramic block gauge: LK-501/503). *2 Repeatability was obtained using KEYENCE's analogue sensor controller (RD-50) with the number of averaging measurements set to 64. Note: The ripple of the analogue output may be 1 mV or more due to co mmon mode noise when observed with an oscilloscope or a high-speed A/D conversion board. *3 When measurement is impossible, 12 V (31.2 mA) is output. |