We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are seeking Keyence LK-085 , make contact with FAMAGA, the world's prime distributor of streamlined equipment. Our company has progressed for more than ten years - these are years of experience, which are described in the quality of goods and private attention to each user. We praise everyone, who conspired with us - thus, our regular consumers accept the most desirable purchase conditions and discounts on the machine made streamlined equipment market. At this moment, there are more than 3500 such consumers, and we constantly make new agreements. More than 700 transactions are made per day, because FAMAGA delivers all over the globe Germany, United Kingdom, Portugal, Georgia, Saudi Arabia, Turkmenistan, Cyprus, Swaziland, Lebanon, Bosnia and Herzegovina, Tanzania, Greece, Ukraine, Kiribati, Albania, Laos, Afghanistan, Jordan, Uruguay, Chile, Kazakhstan, Czech Republic, Lithuania, United States, Paraguay, Ireland, Uzbekistan, Burundi, Australia, Armenia, Vietnam, Equatorial Guinea, Luxembourg, Denmark, Ecuador, Senegal, Iceland, Ghana, Yemen, Mali, Seychelles, India, Cape Verde, Hungary, Tajikistan. A well-built logistics series and a partnership network allow us to dispatch our goods anywhere in the globe as soon as possible without disreputing product quality.
A special source of dignity for FAMAGA is its team members, each of whom contributes to our work. We request into our team only professionals, who already have experience in the range of factory-made equipment.
All outputs from FAMAGA are verified - we are responsible for the cause of our work. Nowadays, more than 10 million units of products have been supplied, and this bulk is ascending every day. We are pleased that customers choose FAMAGA again and again, and we are happy to make more exceptional and technologically modern industrial equipment so as stay in control.
To get some advice or book, contact us or write to the online chat on our official website. You can also dispatch a list of the desirable equipment to the email of corporation - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
Model | LK-085 | |
Type | Sensor head Standard Sensor head | |
Reference distance | 80 mm (Fine target measurement (focused spot type))76.7 mm (Transparent/mirror target measurement (specular reflection type)) | |
Measuring range | ±15 mm | |
Light source | Type | Red semiconductor laser |
Wavelength | 670nm (Visible light), Class 2 laser product (JIS C6802) | |
Output | 0.95 mW maximum | |
Spot diameter (at standard distance) | Approx. 70 x 1,100 µm | |
Linearity | ±0.1% of F.S. | |
Repeatability | 3 µm*1 | |
Analogue output | Output voltage | ±5 V (3 µm/mV)*2 |
Impedance | 100 ? | |
Output current | 4 to 20 mA (350 ? maximum)*2*3 | |
Alarm output | NPN: 100 mA max. (40 V max.) (N.C.), Residual voltage: 1 V max. | |
Sampling cycle | 1,024 µs | |
Other functions | Auto-zero, analog output holding when an alarm occurs, gain switching, response switching, span and shift adjustment | |
Temperature characteristics | 0.01% of F.S./°C | |
Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less |
Maximum current consumption | 400 mA max. | |
Environmental resistance | Enclosure rating | IP67 |
Ambient light | Incandescent or fl uorescent lamp: 10,000 lux max. | |
Ambient temperature | 0 to +50 °C (No condensation) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Material | Aluminium die-cast | |
Weight | Approx. 385 g (including cable) | |
*1 Repeatability was obtained using KEYENCE's analogue sensor controller (RD-50) with the number of averaging measurements set to 64. Note: The ripple of the analogue output may be 1 mV or more due to co mmon mode noise when observed with an oscilloscope or a high-speed A/D conversion board. *2 LK-010: When measurements cannot be performed, this is 12 V (21 mA). LK-035/030, LK-085/080, and LK-500: When measurements cannot be performed, this is 12 V (31.2 mA). *3 The ±5 V analog voltage output range (the ± |