We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Keyence
Country
Japan
Name
LR-TB2000
Type
Mounting bracket
Description
Sensor Anwesenheit von Paketen im Geschäft
Stock availability:
On request
If you are pursuing Keyence LR-TB2000 , make contact with FAMAGA, the world's influential vendor of manufacturing equipment. Our company has advanced for more than ten years - these are ages of experience, which are expressed in the quality of goods and individual attention to each purchaser. We admire everyone, who engaged with us - thus, our regular consumers get the most convenient purchase terms and discounts on the industrial equipment market. Today, there are more than 4000 such consumers, and we constantly arrange new agreements. More than 700 proceedings are resolved per day, because FAMAGA delivers all over the world Germany, United Kingdom, Saudi Arabia, Pakistan, Burkina Faso, Dominica, Kuwait, Armenia, Madagascar, United States, Vietnam, France, Nepal, Gambia, Morocco, Djibouti, Russia, Fiji, Uganda, Yemen, Thailand, East Timor, Japan, Georgia, Switzerland, Croatia, Haiti, Lithuania, Latvia, Libya, Finland, Philippines, Nigeria, Guyana, Nicaragua, Cape Verde, Sudan, Mexico, Belarus, Namibia, Estonia, Angola, Egypt, Ghana, Guatemala, New Zealand, Mozambique, Senegal, United Arab Emirates, Brunei. A advanced logistics bond and a partnership network allow us to ship our items anywhere in the globe quickly without damaging product quality.
A particular source of dignity for FAMAGA is its employees, each of whom contributes to our work. We invite into our team only professionals, who already have experience in the range of industrial equipment.
All spare parts from FAMAGA are affirmed - we are responsible for the cause of our work. Nowadays, more than 10 million units of products have been supplied, and this number is increasing every day. We are happy that customers choose FAMAGA again and again, and we are glad to make more advanced and technologically modern industrial equipment so as keep on top of it.
To request or book, contact us or write to the online chat on our official website. You can also direct a list of the required equipment to the email of corporation - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
Model | LR-TB2000 | |
Type | Cable | |
Detectable distance | 60 to 2000 mm*1 | |
Spot diameter | Approx. 4 mm | |
Response time | 1 ms/10 ms/25 ms/100 ms/1000 ms selectable | |
Light source | Type | Red laser (660 nm) |
Laser class | Class 2 laser product (IEC60825-1,FDA (CDRH) Part1040.10*2) | |
Mutual interference prevention function | 4 units (when using the interference prevention function) | |
Timer | OFF/OFF delay/ON delay/One-shot | |
Power voltage | 20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS | |
Current consumption | 45 mA or less (without load)*3 | |
I/O | Control output | NPN open collector/PNP open collector selectable 30 VDC or less, 50 mA or less, residual voltage: 2 V or less, N.O./N.C. selectable *4*5 |
External input | Switchable between transmission OFF, teaching, and reference surface update Short-circuit current: 1 mA or less for both NPN and PNP For the applied voltage, see the wiring diagrams (pages 2 and 3 in the instruction manual). For the input times, see the time charts (page 4 in the instruction manual).*6 | |
Analogue output | - | |
Protection circuit | Protection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surge | |
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) |
Ambient light | Incandescent lamp/Sunlight: 10,0000 lux or less | |
Ambient temperature | -20 to +55 °C (No freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 1,000 m/s2, 6 times in each of the X, Y, and Z directions | |
Material | Case: Zinc die cast (Nickel chrome plating), Indicator cover and buttons: PES, Lens cover and display: PMMA (scratch-resistant coating specifications), Cable bushing: PBT, Cable: PVC | |
Accompanying items | Instruction manual, Laser warning and explanation labels | |
Weight | Approx. 125 g (Including cable) | |
*1 The range for displayable distance is from 50 to 2200. *2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *3 145 mA or less (with load) *4 You can select the I/O from the following combinations. Control output ? 2, control output + external input Control output + analogue output (LR-TB5000/TB5000C/TB5000CL only), External input + analogue output (LR-TB5000/TB5000C/TB5000CL only) (For details on the setting method, see the instruction manual.) *5 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com). If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office. *6 You can select the I/O from the following combinations. Control output ? 2, control output + external input, IO-Link (For details on the setting method, see page 3 of the instruction manual.) |