Specifications IX-1050

If you are pursuing Keyence IX-1050 , reach FAMAGA, the world's central distributor of machine made equipment. Our company has existed for more than ten years - these are cycles of experience, which are symbolized in the quality of outcomes and special attention to each client. We admire everyone, who joined with us - thus, our regular clients obtain the most beneficial purchase forms and discounts on the manufacturing equipment market. Nowadays, there are more than 3500 such clients, and we constantly compose new agreements. More than 600 contracts are concluded per day, because FAMAGA supplies all over the earth . A well-elaborated logistics connection and a partnership network let us to conduct our elements anywhere in the planet immediately without disreputing product quality.

A particular source of pride for FAMAGA is its workers, each of whom contributes to our work. We propose into our team only specialists, who already have experience in the direction of machine made streamlined equipment.

All outputs from FAMAGA are guaranteed - we are responsible for the cause of our work. Nowadays, more than 10 million units of products have been delivered, and this amount is rising every day. We are glad that clients choose FAMAGA again and again, and we strive to make more exceptional and technologically modern industrial equipment so as to stay on the top.

To request or make a request, get in touch with us or write a message to the online chat on our official website. You can also dispatch a list of the desirable equipment to the email of firm - we will contact you ourselves with a worked out commercial proposal from FAMAGA.

Features IX-1050

Sensor Amplifier Unite d’extension
Model IX-1050
Main unit / expansion unit Expansion unit
Display Min. display unit 10 µm*1
Display range ±999.99 to ±999 mm (with 4 selectable steps)*1
Tools Scan mode Height, Height difference, Max./Min., Height difference calculation, Thickness calculation, Height detection, Monochromatic detection, Position adjustment (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool*2
Line mode Height (Ave./Max./Min.), Height difference (Ave./Max./Min.), Height difference calculation, Thickness calculation, Position adjustment, Tilt correction (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool, Alignment adjustment: 1 tool*2
Other functions Common ZERO/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement, Zero/offset recording, Capture mode (HDR) Sensor date/time Information addition, N.O./N.C. switching, I/O monitor, Automatic brightness adjustment, Lighting (ON/OFF), Total judgement conditions, NPN/PNP switching, Simultaneous main unit/expansion unit input, Light interference prevention, Security
Scan mode Measurement range, Measurement position (small/standard/large), Measurement mode, Measurement noise elimination, Imaging mode (high gain), Tilt correction (fixed or real-time correction), Glare removal, Trigger input (internal/external), Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Fixed reference area, Mask outline, Rotation range
Line mode Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.)
Input Non-voltage input/voltage input is switchable For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)
Input Number of inputs 8 (IN1 to IN8)
Function IN1: External trigger up/down timing, IN2 to IN8: Enable by assigning optional functions Assignable functions: Program switching, Laser emission stop, Zero/offset (batch), Reset (error only), Reset (judgement value only) Reset (judgement value and error)
Output Open collector output, NPN/PNP switchable, N.O./N.C. switchable For open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 1.5 V or less For open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 2 V or less
Output Number of outputs 10 (OUT1 to OUT10)
Function Enable by assigning the optional functions Assignable functions: Total judgement result (All OK, Any OK/NG), run, busy, error, position adjustment result, tilt correction result, Monochromatic detection / Height detection tool result (OK/NG), Height / height difference / Max./Min. / calculation tool result (OK/NG/HIGH/LO), Alarm
Analogue voltage output Not available
Analogue current output
Number of programs 32
Statistical information Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) *1*3
Detection history Saved history 100*4
Save conditions Selectable from NG only / All*4
Ethernet Standard Not available
Connector
Interface compatibility CC-Link / DeviceNetTM / EtherNet/IPTM / EtherCAT? / RS-232C / BCD / PROFINET / PROFIBUS / TCP/IP output*5
Number of connectible units Main units: 1, Expansion units: 1, Communication units (DL): 1
Ratings Power voltage Supplied from main unit
Current consumption Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load) *6
Environmental resistance Operating ambient temperature 0 to +50°C (No freezing)
Operating ambient humidity 35 to 85% RH (No condensation)
Material Main unit case: PC / Power connector: PA, POM / Analogue output connector: PA, POM / I/O connector: PA / Head connector: Zinc + Ni plating, PA/Ethernet connector: Copper alloy + Ni plating / Rear heat sink: Aluminium / Main unit rear DIN rail fixing tab: POM / Nameplate: PC
Weight Approx. 190 g
*1 For displaying on an IX Series control panel or PC software. *2 Configurable for each program. *3 When sample hold (edge), peak/bottom/P-P hold (level/edge) is set. *4 Saves to the sensor amplifier’s internal memory. Detection history saved inside the sensor amplifier can be backed up to a PC using the USB memory stick connected to the IX Series control panel or PC software. *5 When a DL Series device is used. Contact KEYENCE for information on other interfaces. *6 Includes a DL Series communication unit.