We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Keyence
Country
Japan
Name
IL-300
Category
Industrial Safety
Type
Mounting bracket
Description
IL-300 Lasersensorköpfe
Stock availability:
On request
Model | IL-300 | |
Reference distance | 300 mm | |
Measurement range | 160 to 450 mm | |
Light source | Type | Red semiconductor laser, wavelength: 655 nm (visible light) |
Laser class | Class 2 (FDA (CDRH) Part1040.10)*1 Class 2 (IEC 60825-1) | |
Output | 560 µW | |
Spot diameter (at standard distance) | Approx. o0.5 mm | |
Linearity | ±0.25% of F.S. (160 mm to 440 mm)*2*3 | |
Repeatability | 30 µm*4 | |
Sampling rate | 0.33/1/2/5 ms (4 levels available) | |
Operation status indicators | Laser emission warning indicator: Green LED, Analogue range indicator: Orange LED, Reference distance indicator: Red/Green LED | |
Temperature characteristics | 0.08% of F.S./°C*3 | |
Environmental resistance | Enclosure rating | IP67 |
Pollution degree | 3 | |
Ambient light | Incandescent lamp: 5,000 lux*5 | |
Ambient temperature | -10 to +50 °C (No condensation or freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Material | Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC | |
Weight | Approx. 135 g | |
*1 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice No.50. *2 Value when measuring the KEYENCE standard target (white diffuse object). *3 F.S. of each model is as follows. IL-030: ±5 mm IL-065: ±10 mm IL-100: ±20 mm IL-300: ±140 mm IL-600: ±400 mm *4 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 128. For the IL-300/IL-600, the sampling rate is 2 ms. *5 Value when the sampling rate is set to 2 ms or 5 ms. |