We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are looking for Keyence SL-V96HM , contact FAMAGA, the world's key producer of factory-made equipment. Our company has lasted for more than ten years - these are years of experience, which are expressed in the quality of products and personalseparate attention to each consumer. We appreciate everyone, who worked with us - therefore, our regular customers obtain the most favorable purchase conditions and discounts on the industrial equipment market. At this moment, there are more than 4000 such customers, and we constantly form new agreements. More than 650 transactions are made per day, because FAMAGA operates all over the world Germany, United Kingdom, Saudi Arabia, China, Azerbaijan, Zimbabwe, East Timor, Mali, Dominica, Mexico, Samoa, Liechtenstein, Canada, Tanzania, Eritrea, Belize, Poland, Serbia, Benin, Syria, Jamaica, South Sudan, Angola, Latvia, Sierra Leone, Cyprus, Malaysia, Nepal, Uzbekistan, Bosnia and Herzegovina, Mozambique, Comoros, Nicaragua, South Korea, Kiribati, Togo, Switzerland, Croatia, Sweden, Peru, Burkina Faso, Finland, Brunei, Belarus, Madagascar, Panama, Senegal. A well-developed logistics bond and a partnership network allow us to deliver our goods anywhere in the world as soon as possible without compromising product quality.
A special source of pride for FAMAGA is its employees, each of whom contributes to our work. We accept into our team only professionals, who already have experience in the field of industrial equipment.
All goods from FAMAGA are guaranteed - we are responsible for the outcome of our work. At the moment, more than 10 million units of products have been shipped, and this number is growing every day. We are proud that customers choose FAMAGA again and again, and we strive to make more advanced and technologically developed industrial equipment so as not to lower the bar.
To consult or place an order, call us by phone or write to the online chat on our official website. You can also send a list of the required equipment to the email of our company - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
Model | SL-V96HM | ||
Detection capability | o25 mm | ||
Beam axis spacing/Lens diameter | 20 mm/o5 mm | ||
Effective aperture angle | Max. ±2.5 ° (When operating distance is 3 m or more) | ||
Working distance | 0.1 m to 9.0 m (detection height of 1,260 mm or l ess) 0.1 m to 7.0 m (detection height of 1,400 mm or more) | ||
Response time (ms) | ON>OFF | 19.1*1 | |
OFF>ON | 59.1*1 | ||
Light source | Infrared LED (850 nm) | ||
Operation mode | Turns on when no interruptions are present in the detection zone (excluding when the muting function is used) | ||
OSSD output | Output | 2 outputs each for PNP and NPN. Can be changed by using the connector cable. | |
Max. l oad current | 500 mA*2 | ||
Residual vol tage (during ON) | Max. 2.5 V (with a cable length of 7 m) | ||
Leakage current | Max. 100 µA*3 | ||
Max. capacitive load | 2.2 µF (with a load resistance of 100 ?) | ||
Load wiring resistance | Max. 2.5 ?*4 | ||
Non safety-rel atedoutput | AUX | Output with automatic PNP/NPN switching function, 50 mA max. | |
Interlock-reset-ready output | |||
Alarm output | |||
Clear/blocked output | |||
State information output 1, 2 | |||
Muting lamp output | Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected | ||
Input | EDM input | Short-circuit current 10 mA | |
Wait input | Short-circuit current 2.5 mA | ||
Reset input | |||
Muting input 1, 2 | |||
Override input | |||
Protection circuit | Reverse current protection, short-circuit protection for each output, surge protection for each output | ||
Approved standards | EMC | EMS | IEC61496-1, EN61496-1, UL61496-1 |
EMI | EN55011 Class A, FCC Part15B Class A | ||
Safety | IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD) IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe) UL508 UL1998 | ||
Rating | Power voltage | 24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less | |
Current consumption (mA) | When the Centre indicator is ON | Transmitter | 154*6 |
Receiver | 104*6 | ||
When the Centre indicator is OFF | Transmitter | 140*6 | |
Receiver | 83*6 | ||
Environmental resistance | Enclosure rating | IP65/67 (IEC60529) | |
Overvoltage category | II | ||
Ambient light | Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max. | ||
Operating ambient temperature | -10 to +55 °C (No freezing) | ||
Storage temperature | -25 to +60 °C (No freezing) | ||
Operating relative humidity | 15 to 85 % RH (No condensation) | ||
Storage relative humidity | 15 to 95 % RH | ||
Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions | ||
Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | ||
Material | Main unit case | Aluminium | |
Upper case/lower case | Zinc die-cast | ||
Front cover | Polycarbonate, SUS304 | ||
Weight | Transmitter | 3,730 g | |
Receiver | 3,760 g | ||
*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of theresponse times of al l the individual SL-V units, but the response time (OFF to ON) is the sameas that of a singl e SL-V unit. e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), andSL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms. *2 When used under ambient temperature between 45 to 55 °C, the maximum should not exceed 300 mA. *3 Applies to situations when power is either off or disconnected. *4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cable) must be 2.5 ? or less to ensure operations. If using the NPN output with a cable length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 ? or less. *5 When used under ambient temperature between 45 to 55 °C, use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA). *6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by 10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of both transmitter and receiver is fixed.) In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the OFF state. In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON state. |