Name
SZ-V32N
Type
Mounting bracket
Description
Network type (PROFIsafe) Standard
Stock availability:
On request
If you are pursuing Keyence SZ-V32N , connect FAMAGA, the world's top vendor of streamlined equipment. Our company has existed for more than ten years - these are years of experience, which are symbolized in the quality of products and special attention to each purchaser. We cherish everyone, who worked with us - therefore, our regular purchasers procure the most helpful purchase terms and discounts on the industrial equipment market. At present, there are more than 4000 such buyers, and we constantly form new agreements. More than 750 transactions are made per day, because FAMAGA operates all over the earth Germany, United Kingdom, Kazakhstan, Bahamas, Gambia, Romania, Panama, United States, Niger, Mongolia, Czech Republic, Slovenia, Japan, Kiribati, Samoa, Peru, Moldova, Latvia, Costa Rica, Central African Republic, Poland, Malta, Botswana, Mali, China, Armenia, Fiji, Pakistan, Syria, Morocco, Australia, Indonesia, Ireland, Angola, Djibouti, Malaysia, Guatemala, Serbia, Mauritania, Tajikistan, Libya. A well-shaped logistics series and a partnership network guide us to conduct our elements anywhere in the world on-time without compromising product quality.
A specific source of good name for FAMAGA is its workers, each of whom contributes to common cause. We call into our team only specialists, who already have experience in the range of industrial equipment.
All outcomes from FAMAGA are guaranteed - we are responsible for the outcome of our work. Now, more than 10 million units of products have been provided, and this number is increasing every day. We are glad that customers choose FAMAGA again and again, and we are pleased to make more exceptional and technologically developed industrial equipment so as to stay on the top.
To consult or place an order, phone us or send a message to the online chat on our official website. You can also send a list of the needful equipment to the email of corporation - we will contact you ourselves with a made commercial proposal from FAMAGA.
Model | SZ-V32N*1 | ||
Type | Network Type | ||
Detection capability | Minimum detectable object size | Diameter: 20, 30, 40, 50, 70, 150 mm (depends on the setting), Reflectance: 1.8% min., Speed: 1.6 m/s max.*2 | |
Detectable angle | 190° (-5° to 185°) | ||
Response time (ON to OFF) | Standard Mode | Scan Cycle A | 160 ms (2 scans) to 1280 ms (16 scans)*3*4 |
Scan Cycle B | 168 ms (2 scans) to 1344 ms (16 scans)*3*4 | ||
Scan Cycle C | 176 ms (2 scans) to 1408 ms (16 scans)*3*4 | ||
High Speed Mode | Scan Cycle A | 80 ms (2 scans) to 640 ms (16 scans)*3*4 | |
Scan Cycle B | 84 ms (2 scans) to 672 ms (16 scans)*3*4 | ||
Scan Cycle C | 88 ms (2 scans) to 704 ms (16 scans)*3*4 | ||
Response time (OFF to ON) | Response time of ON to OFF + 150 ms | ||
Protection zone | Minimum detectable object size: 70 / 150 mm | Standard Mode: 8.4 m / High Speed Mode: 5.7 m | |
Minimum detectable object size: 50 mm | Standard Mode: 5.6 m / High Speed Mode: 3.8 m | ||
Minimum detectable object size: 40 mm | Standard Mode: 4.3 m / High Speed Mode: 2.9 m | ||
Minimum detectable object size: 30 mm | Standard Mode: 2.9 m / High Speed Mode: 2.0 m | ||
Minimum detectable object size: 20 mm | Standard Mode: 1.6 m / High Speed Mode: 1.1 m | ||
Warning zone | Minimum detectable object size: 70 / 150 mm | Standard Mode: 26 m / High Speed Mode: 23 m*5 | |
Minimum detectable object size: 50 mm | Standard Mode: 25 m / High Speed Mode: 21 m*5 | ||
Minimum detectable object size: 40 mm | Standard Mode: 24 m / High Speed Mode: 20 m*5 | ||
Minimum detectable object size: 30 mm | Standard Mode: 23 m / High Speed Mode: 18 m*5 | ||
Minimum detectable object size: 20 mm | Standard Mode: 21 m / High Speed Mode: 15 m*5 | ||
Additional safety distance | 100 mm*6 | ||
Maximum measurement distance | 60 m*7 | ||
Maximum number of banks | Max. 32 banks*8 | ||
Multiple scanner heads | Max. 3 | ||
Camera | -*9 | ||
Display | QVGA 2.2 inch colour LCD | ||
Light source | Type, wavelength | Infrared laser diode, 905 nm | |
Laser class | IEC | Class 1 IEC / EN 60825-1 | |
FDA | Class 1 FDA 21 CFR 1040.10, 1040.11 (Laser Notice No.50)*10 | ||
JIS | Class 1 JIS C6802 | ||
Control output (OSSD output) | Output type | PNP or NPN transistor output (settings configurable with SZ-V Configurator) | |
Number of outputs | 2 outputs | ||
Max. load current | 500 mA*11 | ||
Residual voltage | Max. 2.5 V (with a cable length of 5 m) | ||
OFF-state voltage | Max. 2.0 V (with a cable length of 5 m) | ||
Leakage current | Max. 1 mA*12 | ||
Max. capacitive load | 2.2 µF (with a load resistance of 100 ?) | ||
Load wiring resistance | Max. 2.5 ? | ||
Input (safety-related) | PNP | ON-voltage: 10 to 30 V, OFF-voltage: Open or 0 to 3 V, Short-circuit current: Approx. 2.5 mA (EDM input: Approx. 10 mA) | |
NPN | ON-voltage: 0 to 3 V, OFF-voltage: Open or 10 V to Power voltage, Short-circuit current: Approx. 2.5 mA (Approx. 10 mA for EDM) | ||
Non safety-related output (AUX output) | Output type | Transistor output (PNP or NPN, settings configurable with SZ-V Configurator) | |
Number of outputs | 4 outputs | ||
Max. load current | 50 mA | ||
Residual voltage (during ON) | Max. 2.5 V (with a cable length of 5 m) | ||
Muting lamp | Connectable to incandescent lamp (24 VDC, 1 to 5.5 W) and LED lamp (load current: 10 to 230 mA) | ||
Interface | USB | USB 2.0 | |
Ethernet | Standard | IEEE802.3u (100BASE-TX) | |
Transmission rate | 100 Mbps | ||
Cable | Category5 or higher STP (Shielded Twisted Pair) or UTP (Unshielded Twisted Pair) cable | ||
Connector | RJ45 (IP65 connector) 2 ports | ||
Networking/data output | PROFIsafe, PROFINET, EtherNet/IPTM, UDP | ||
Cable length | Power cable | 30 m or less*13 | |
Connection cable | 20 m or less each*14 | ||
Ethernet cable | 100 m or less*15 | ||
Approved standards | EMC | EMS | IEC61496-1, EN61496-1, UL61496-1 (Type3 ESPE) |
EMI | EN55011 Class A, FCC Part15B Class A, ICES-003 Class A | ||
Safety | IEC61496-1, EN61496-1, UL61496-1 (Type3 ESPE), IEC61496-3, EN61496-3 (Type3 AOPDDR), IEC61508, EN61508, IEC62061, EN62061 (SIL2/SILCL2), EN ISO13849-1:2015 (PLd, Category3), IEC61784-3-3, UL508, UL1998, CSA C22.2 No.14, CSA C22.2 No.0.8 | ||
Rating | Power consumption | 13.4 W (without load), 50.8 W (with load)*16 | |
Power voltage | When using a converter power supply: 24 VDC ±10 %, Ripple (P-P) 10 % or less When using a battery: 24 VDC +20 % /-30 % | ||
Environmental resistance | Enclosure rating | IP65 (IEC60529) | |
Ambient light | Incandescent lamp: 1,500 lux or less*17 | ||
Operating ambient temperature | -10 to +50 °C (No freezing) | ||
Storage temperature | -25 to +60 °C (No freezing) | ||
Operating relative humidity | 35 to 85 % RH (No condensation) | ||
Storage relative humidity | 35 to 95 % RH | ||
Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions | ||
Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | ||
Material | Scanner head | Main unit case | Magnesium |
Window | Polycarbonate, PEI | ||
Indicator part | -*9 | ||
Display unit | case | Magnesium, PPS, Polycarbonate | |
System memory | Aluminum, PPE | ||
Weight | Approx. 2,300 g | ||
*1 Integrated models include display unit, scanner head, system memory and a connection cable (SZ-VS005). *2 If the object to be detected moves perpendicular to the detection plane, SZ-V cannot detect the object moving at speed over 1.6 m/s, regardless of the encoder setting. *3 The response time, protection zone, and warning zone are affected by the operation mode. *4 When PROFIsafe is used with the SZ-V32N, 6 ms is added to the response time. *5 20% or more reflectance is necessary for the minimum detectable object in the warning zone. *6 If there is a highly reflective background within 1.5 m from the boundary of the protection zone, 200 mm must be added as supplementary necessary distance to the protection zone when calculating the minimum safety distance. *7 Even when using the network data output, the maximum measured output distance is 60 m. *8 When PROFIsafe is used with the SZ-V32N, maximum number of banks is 16. *9 Only applicable for the type with a camera. *10 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *11 The load current calculation of the OSSD output and AUX output is 1.2 A or less when using one scanner head, 0.8 A or less when using two scanner heads, and 0.3 A or less when using three scanner heads. *12 Includes when the power is OFF. *13 10 m or less when supplying power from a battery. *14 When supplying power from a battery, the length of each connection cable should be 10 m or less when using two scanner heads, and 5 m or less when using three scanner heads. *15 Distance between SZ-V and Ethernet switch *16 When using the SZ-V with series connected sensor heads, it is necessary to add 9.4 W per scanner head. Also, power consumption may temporarily be higher (maximum 3.6 W). Power consumption will be within the specification after SZ-V moves to normal operation. *17 An ambient light source should not be located within ±5° of the detection plane. |