Specifications SM8000

If you are questing IFM SM8000, contact FAMAGA, the world's principle company of factory-made equipment. Our company has existed for more than ten years - these are ages of experience, which are represented in the quality of products and private attention to each client. We appreciate everyone, who engaged with us - hence, our regular consumers receive the most favorable purchase conditions and discounts on the manufacturing equipment market. Nowadays, there are more than 4000 such consumers, and we constantly sign new agreements. More than 750 agreements are achieved per day, because FAMAGA operates all over the world . A well-elaborated logistics network and a partnership network cheer us to dispatch our items anywhere in the earth quickly without disreputing product quality.

A specific source of dignity for FAMAGA is its staff members, each of whom contributes to common cause. We request into our team only specialists, who already have experience in the field of machine made streamlined equipment.

All outcomes from FAMAGA are verified - we are responsible for the outcome of our work. At the moment, more than 10 million units of products have been provided, and this quantity is ascending every day. We are proud that consumers choose FAMAGA again and again, and we are eager to make more progressive and technologically advanced industrial equipment so as not to lower the bar.

To get some advice or make a request, get in touch with us or write a message to the online chat on our official website. You can also send a list of the needful equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.

Features SM8000

Application
ApplicationSum function, for general industrial use
Installationpipe connection with adapter
MediumConductive liquids, Water, water-based liquids
Medium note
Conductivity: ? 20 µS/cm
Viscosity: < 70 mm?/s (40 °C)
Measured medium temperature [°C]-10…70
Pressure strength [bar] 16
MAWP (for use according to CRN) [bar]11.2
Electronic data
Operating voltage [V]18…30 DC, (according to EN 50178 SELV/PELV )
Current consumption [mA]95, (24 V)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs/outputs
Number of inputs and outputsNumber of digital outputs: 2, Number of analog outputs: 1
Inputs
Inputsreset counter
Outputs
Total number of outputs2
Output signalSwitching signal analog New signal, pulse signal, IO-Link, (configurable)
Electrical versionPNP/NPN
Number of digital outputs2
Output signal functionnormally open / normally closed, (parameterizable)
Max. voltage drop DC switching output [V]2
DC switching output load current [mA]200
Number of analog outputs1
Analog current output [mA] 4…20, (scalable)
Max. load [?]500
Analog voltage output [V]0…10, (scalable)
Min. load resistance [?]2000
Pulse outputFlowmeter
Short-circuit protectionyes
Short-circuit protection typeclocked
Overcurrent protectionyes
Measurement/setting range
Range measurements
0.2…100 l/min0.01…6 m?/h
Display range
-120…120 l /min-7.2…7.2 m?/h
Resolution
0.1 l/min0.005 m?/h
Setting point SP
0.7…100 l/min0.04…6 m?/h
Reset point rP< /tr>
0.2…99.5 l/min0.01…5.97 m?/h
The starting point of the analog signal, ASP
0…80 l/min0…4.8 m?/h
Analogue end point, AEP
20…100 l/min1,2…6 m?/h
Width step
0.1 l/min0.005 m?/h
Momentary flow control
Pulse value0.00001 …100 000 m?
Pulse length [s]0.0025…2
Temperature control
Measuring range [°C]-20…80
Resolution [°C]0.2
Setting point SP [°C]-19.2…80
Reset point rP [°C]-19.6…79.6
Analog start point [°C]-20…60
Analogue end point [°C]0…800…80
In steps of [°C]0.2
Accuracy/Uncertainty
Flow rate control
Accuracy (in measuring range)± (0.8 % MW + 0.5% MEW)
Repeatability± 0.2% MEW
Temperature control
Accuracy [K]± 2.5 (Q > 5 l/min)
Response Time
Flow Rate Control
Response time [s]0.15, (dAP = 0)
Programmable delay time dS, dr [s] 0…50
Switching output damping dAP [s]0…5
Temperature control
Dynamics of response response T05 / T09 [s]T09 = 20 (Q > 5 l/min )
Software / Programming
Parameter selectionFlow rate control, flow meter, counter with presetting, Temperature control, hysteresis / window, normally open / normally closed, switching logic, current output / voltage output / pulse output, Start delay, display can be switched off, Display
Interfaces
Communication interfaceIO-Link
Transmission methodCOM2 (38.4 kBaud)
IO-Link test1.1
SDCI standard IEC 61131-9
IO-Link Device ID575 / 00 02 3f
ProfilesSmart Sensor: Process Data Variable, Device Identification, Device Diagnosis
SIO modeyes
Desired port typeA
Analog operating data3
Binary operating data2
Min. cycle time [ms]5
Operating conditions
Ambient temperature [°C]-10…60
Storage temperature [°C]-25…80
Degree of protectionIP 67
Tests / approvals
EMC
DIN EN 60947-5-9
Impact resistance
DIN IEC 68-2-2720 g (11 ms)
Vibration resistance
DIN IEC 68-2-65 g (10…2000 Hz)
MTTF [g Code]145
Pressure Equipment DirectiveGood engineering practice, can be used for fluid group 2, group liquids 1 on request
Mechanical data
Weight [g]641.5
Materialstainless steel steel (1.4404 / 316L), PBT-GF20, PC, FKM, TPE mediumstainless steel steel (1.4404 / 316L), PEEK, FKM
Process connectionG 1 DN25 threaded connection Flat seal
Displays / Controls
Display
Display6 x LED, green (l/min, m?/h, l, m?, 10?, °C)
Output status 2 x LED, yellow
Measured valuesalphanumeric display, 4 digits
programmingalphanumeric display, 4 digits
Notes
Notes
MW = Measured value
MEW = Upper limit of measuring range
Pack quantity1 piece
electrical connection
ConnectionConnector: 1 x M12, Contacts: gold-plated
Diagrams and Graphs
Pressure Loss
dPPressure loss
Qvolumetric consumption