We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are looking for Euchner CES-AR-CL2-CH-L20-109053 109053, communicate with FAMAGA, the world's main supplier of mechanized equipment. Our company has worked for more than ten years - these are ages of experience, which are outlined in the quality of outcomes and particular attention to each purchaser. We esteem everyone, who engaged with us - hence, our regular customers receive the most beneficial purchase forms and discounts on the factory-made equipment market. Nowadays, there are more than 4 thousand such purchasers, and we constantly form new agreements. More than 600 purchases are terminated per day, because FAMAGA supplies all over the planet Germany, United Kingdom, Guyana, San Marino, Cape Verde, Albania, Malaysia, Sweden, Saudi Arabia, Honduras, Indonesia, Philippines, Togo, South Sudan, Botswana, Tajikistan, Bhutan, Belarus, Mauritania, Lithuania, Haiti, Liberia, Guatemala, Argentina, East Timor, Austria, Greece, Peru, Latvia, Estonia, India, Poland, Denmark, Angola, Panama, Russia, Burundi, Switzerland, Burkina Faso, Georgia, Comoros, Serbia, North Korea, Syria, Montenegro. A advanced logistics network and a partnership network cheer us to deliver our goods anywhere in the planet immediately without compromising product quality.
A particular source of honor for FAMAGA is its personnel, each of whom contributes to common cause. We propose into our team only professionals, who already have experience in the direction of manufacturing equipment.
All products from FAMAGA are assured - we are responsible for the aftereffect of our work. Now, more than 10 million units of products have been delivered, and this amount is amounting every day. We are happy that clients choose FAMAGA again and again, and we are eager to make more progressive and technologically innovative industrial equipment so as to stay on the top.
To ask a question or make a request, phone us or write a message to the online chat on our site. You can also forward a list of the necessary equipment to the email of firm - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
OUT | Monitoring output (semiconductor) |
RST | Reset input |
Designation | Function | Conductor coloring of connection cable |
---|---|---|
IB | Enable input for channel 2 | WH |
UB | Power supply, DC 24 V | BN |
OA | Safety output, channel 1 | GN |
OB | Safety output, channel 2 | YE |
OUT | Monitoring output | GY |
IA | Enable input for channel 1 | PK |
0V | Ground, DC 0 V | BU |
RST | Reset input | RD |
Housing material | Plastic, PBT |
Weight | |
Net | 0,7 kg |
Ambient temperature | |
Cable static | -30 ... 65 °C |
Cable dynamic | -25 ... 65 °C |
Degree of protection | IP67, IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.120 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.1 Nm |
Ready delay | 10 s |
Switching frequency | max.1 Hz |
Connection | connection cable PUR, length 20m |
Bending radius | |
static | 5 x cable diameter |
Dynamic | 10 x cable diameter |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5 % |
Current consumption | max.50 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs OA/OB | |
Test pulses | max.1 ms |
Test-pulse interval | min.140 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 200 mA |
Output voltage | |
HIGH U(OA) / U(OB) | UB-1,5V ... UB V DC |
LOW U(OA) / U(OB) | 0 ... 1 V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 1.9 x 10-9 |
Mission time | 20 |
Switch-on distance | 15 mm |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Assured operating distance Sao | min.10 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 19 mm |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Assured operating distance Sao | min.14 mm |
Switching hysteresis | min.1 mm |