We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CTP-I2-AP-U-HA-AZC-SA-126258
Part number
126258
Description
Transponder-coded safety switch CTP-I2-AP-U-HA-AZC-SA
Stock availability:
On request
If you are looking for Euchner CTP-I2-AP-U-HA-AZC-SA-126258 126258, connect FAMAGA, the world's central distributor of manufacturing equipment. Our company has progressed for more than ten years - these are ages of experience, which are depicted in the quality of items and private attention to each buyer. We praise everyone, who joined with us - therefore, our regular customers accept the most flexible purchase forms and discounts on the factory-made equipment market. At this time, there are more than 4 thousand such consumers, and we constantly sign new agreements. More than 700 contracts are concluded per day, because FAMAGA operates all over the planet Germany, United Kingdom, Guyana, Mozambique, Latvia, Botswana, Oman, Eswatini, Netherlands, Myanmar, Samoa, Burkina Faso, Cape Verde, Yemen, Georgia, Tonga, Dominica, Singapore, Sweden, Montenegro, Croatia, Norway, Morocco, Thailand, Bosnia and Herzegovina, Bulgaria, Afghanistan, Uzbekistan, Seychelles, Kyrgyzstan, Mauritius, Moldova, Serbia, Ireland, Estonia, Iceland, Mauritania, Syria, Albania, Zimbabwe, Mexico, Mali, Togo, Philippines. A well-built logistics chains and a partnership network let us to send our units anywhere in the planet promptly without discrediting product quality.
A particular source of honor for FAMAGA is its personnel, each of whom contributes to common cause. We request into our team only professionals, who already have experience in the range of manufacturing equipment.
All spare parts from FAMAGA are guaranteed - we are responsible for the cause of our work. Nowadays, more than 10 million units of products have been supplied, and this amount is amounting every day. We are happy that purchasers choose FAMAGA again and again, and we are eager to make more exceptional and technologically innovative industrial equipment so as not to lower the bar.
To consult or book, contact us or write a message to the online chat on our site. You can also send a list of the necessary equipment to the email of corporation - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
CTP?I2 | Guard locking actuated by power-ON applied and spring released (open-circuit current principle). |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
1 | IMP | Guard locking solenoid control input 24 V DC | WH | |
2 | UB | Operating voltage of AP electronics 24 V DC | BN | |
3 | FO1A | Safety output, channel 1 | GN | |
4 | FO1B | Safety output, channel 2 | YE | |
5 | OI | Diagnostic output | GY | |
6 | OD | Door monitoring output | PK | |
7 | OL | Guard locking monitoring output | BU | |
8 | 0 V | Operating voltage of AP electronics 0 V/control input of guard locking solenoid 0 V | RD |
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,42 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP67 / IP69 / IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | max.1 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M12, 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Open-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Test-pulse interval | min.100 ms |
Test pulses | max.0,3 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 2 A |
External (solenoid operating voltage IMP) | 0,5 ... 8 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 6 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OI | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OL | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |