CTP-I2-AP-U-HA-AZC-SA-126258 Euchner 126258
 CTP-I2-AP-U-HA-AZC-SA-126258 Euchner 126258

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

CTP-I2-AP-U-HA-AZC-SA-126258 126258 Euchner

Manufacturer

Euchner

Country

Germany

Name

CTP-I2-AP-U-HA-AZC-SA-126258

Part number

126258

Description

Transponder-coded safety switch CTP-I2-AP-U-HA-AZC-SA

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications CTP-I2-AP-U-HA-AZC-SA-126258 126258

If you are looking for Euchner CTP-I2-AP-U-HA-AZC-SA-126258 126258, connect FAMAGA, the world's central distributor of manufacturing equipment. Our company has progressed for more than ten years - these are ages of experience, which are depicted in the quality of items and private attention to each buyer. We praise everyone, who joined with us - therefore, our regular customers accept the most flexible purchase forms and discounts on the factory-made equipment market. At this time, there are more than 4 thousand such consumers, and we constantly sign new agreements. More than 700 contracts are concluded per day, because FAMAGA operates all over the planet . A well-built logistics chains and a partnership network let us to send our units anywhere in the planet promptly without discrediting product quality.

A particular source of honor for FAMAGA is its personnel, each of whom contributes to common cause. We request into our team only professionals, who already have experience in the range of manufacturing equipment.

All spare parts from FAMAGA are guaranteed - we are responsible for the cause of our work. Nowadays, more than 10 million units of products have been supplied, and this amount is amounting every day. We are happy that purchasers choose FAMAGA again and again, and we are eager to make more exceptional and technologically innovative industrial equipment so as not to lower the bar.

To consult or book, contact us or write a message to the online chat on our site. You can also send a list of the necessary equipment to the email of corporation - we will contact you ourselves with a prepared commercial proposal from FAMAGA.

Features CTP-I2-AP-U-HA-AZC-SA-126258 126258

  • Safety switch with guard locking and integrated evaluation electronics
  • Guard locking suitable for process protection only
  • Short circuit monitoring
  • Two safety outputs (semiconductor outputs)
  • Up to category 4/PL e according to EN ISO 13849-1
  • With plug connector M12
  • Unicode
  • Door monitoring output
  • Approach directions A, B and C (delivery state)
Approach direction Horizontal Can be adjusted in 90° steps Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Guard locking type
CTP?I2Guard locking actuated by power-ON applied and spring released (open-circuit current principle).
Connector assignment
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connecting cable
1 IMP Guard locking solenoid control input 24 V DC WH
2 UB Operating voltage of AP electronics 24 V DC BN
3 FO1A Safety output, channel 1 GN
4 FO1B Safety output, channel 2 YE
5 OI Diagnostic output GY
6 OD Door monitoring output PK
7 OL Guard locking monitoring output BU
8 0 V Operating voltage of AP electronics 0 V/control input of guard locking solenoid 0 V RD
Housing material
Switch head cover Die-cast zinc
Safety switch housing Fiber glass reinforced thermoplastic
Weight
Net 0,42 kg
Ambient temperature
At UB = 24V DC -20 ... +55 °C
Degree of protection IP67 / IP69 / IP69K
Resilience to vibration In acc. with EN IEC 60947-5-3
Mechanical life 1 x 106
Installation orientation Any
Ready delay max.1 s
Switching frequency max.0,5 Hz
Connection 1 plug connector M12, 8-pin
Approach speed 20 m/min
Guard locking principle Open-circuit current principle
Locking force Fmax 3900 N
Locking force FZh 3000 N
Retention force 20 N
Extraction force 20 N
Actuating force 10 N
Overtravel 5 mm
Electrical connection ratings
Test-pulse interval min.100 ms
Test pulses max.0,3 ms
Operating voltage DC
UUB 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Current consumption
IUB 40 mA
IIMP 400 mA
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Fusing
External (operating voltage UB) 0,25 ... 2 A
External (solenoid operating voltage IMP) 0,5 ... 8 A
Rated insulation voltage Ui max.50 V
Rated impulse withstand voltage Uimp max.0,5 kV
Power consumption 6 W
EMC protection requirements In acc. with EN IEC 60947-5-3
Solenoid duty cycle 100 %
Degree of contamination (external, according to EN 60947-1) 3
Safety class
EN IEC 61140 III
Switching load
According to UL 24V DC, class 2
Safety outputs FO1A / FO1B
Type of output 2 semiconductor outputs, p-switching, short circuit-proof
Switching current
Per safety output FO1A / FO1B 1 ... 150 mA
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1,5 ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Off-state current Ir max.0,25 mA
Switch-on time max.400 ms
Discrepancy time
Both safety outputs max.10 ms In acc. with EN IEC 60947-5-3
Monitoring output OD
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Monitoring output OI
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Monitoring output OL
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Work area
Repeat accuracy R 10 %
Other
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures see operating instructions
Reliability values according to EN ISO 13849-1
Performance Level PL e
Category 4
PFHD 4.1 x 10 -9