Description

Transponder-coded safety switch CTP-AP, M12

Stock availability:

On request

463.92 €

Need cheaper?

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications CTP-L2-AP-U-HA-AZ-SA-124728 124728

If you are pursuing Euchner CTP-L2-AP-U-HA-AZ-SA-124728 124728, make contact with FAMAGA, the world's prime producer of mechanized equipment. Our company has progressed for more than ten years - these are cycles of experience, which are described in the quality of products and particular attention to each orderer. We appreciate everyone, who joined with us - thus, our regular purchasers obtain the most flexible purchase conditions and discounts on the manufacturing equipment market. At this moment, there are more than 4000 such purchasers, and we constantly form new agreements. More than 650 agreements are achieved per day, because FAMAGA delivers all over the world . A well-shaped logistics network and a partnership network allow us to dispatch our goods anywhere in the world immediately without compromising product quality.

A special source of dignity for FAMAGA is its workers, each of whom contributes to our work. We call into our team only experts, who already have experience in the field of machine made streamlined equipment.

All spare parts from FAMAGA are affirmed - we are responsible for the result of our work. Nowadays, more than 10 million units of products have been shipped, and this quantity is increasing every day. We are proud that clients choose FAMAGA again and again, and we strive to make more advanced and technologically advanced industrial equipment so as stay in control.

To request or order, contact us or write to the online chat on our site. You can also dispatch a list of the required equipment to the email of firm - we will contact you ourselves with a prepared commercial proposal from FAMAGA.

Features CTP-L2-AP-U-HA-AZ-SA-124728 124728

  • Safety switch with guard locking and integrated evaluation electronics
  • Short circuit monitoring
  • Two safety outputs (semiconductor outputs)
  • Up to category 4/PL e according to EN ISO 13849-1
  • With plug connector M12
  • Unicode
  • Door monitoring output
  • Approach directions A, B and C (delivery state)
Approach direction Horizontal Can be adjusted in 90° steps Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Guard locking type
CTP?L2Guard locking actuated by power-ON applied and spring released (open-circuit current principle).
Connector assignment
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connecting cable
1 IMP Operating voltage of guard locking solenoid 24 V DC WH
2 UB Operating voltage of AP electronics 24 V DC BN
3 FO1A Safety output, channel 1 GN
4 FO1B Safety output, channel 2 YE
5 OI Diagnostic output GY
6 OD Door monitoring output PK
7 0 V UB Operating voltage of AP electronics 0 V BU
8 IMM Operating voltage of guard locking solenoid 0 V RD
Housing material
Safety switch housing Fiber glass reinforced thermoplastic
Switch head cover Die-cast zinc
Weight
Net 0,42 kg
Ambient temperature
At UB = 24V DC -20 ... +55 °C
Degree of protection IP67 / IP69 / IP69K
Resilience to vibration In acc. with EN IEC 60947-5-3
Mechanical life 1 x 106
Installation orientation Any
Ready delay max.1 s
Switching frequency max.0,5 Hz
Connection 1 plug connector M12, 8-pin
Approach speed 20 m/min
Guard locking principle Open-circuit current principle
Locking force Fmax 3900 N
Locking force FZh 3000 N
Retention force 20 N
Extraction force 20 N
Actuating force 10 N
Overtravel 5 mm
Electrical connection ratings
Test-pulse interval min.100 ms
Test pulses max.0,3 ms
Operating voltage DC
UUB 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Current consumption
IUB 40 mA
IIMP 400 mA
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Fusing
External (operating voltage UB) 0,25 ... 2 A
External (solenoid operating voltage IMP) 0,5 ... 8 A
Rated insulation voltage Ui max.50 V
Rated impulse withstand voltage Uimp max.0,5 kV
Power consumption 6 W
EMC protection requirements In acc. with EN IEC 60947-5-3
Solenoid duty cycle 100 %
Degree of contamination (external, according to EN 60947-1) 3
Safety class
EN IEC 61140 III
Switching load
According to UL 24V DC, class 2
Safety outputs FO1A / FO1B
Type of output 2 semiconductor outputs, p-switching, short circuit-proof
Switching current
Per safety output FO1A / FO1B 1 ... 150 mA
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1,5 ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Off-state current Ir max.0,25 mA
Switch-on time max.400 ms
Discrepancy time
Both safety outputs max.10 ms In acc. with EN IEC 60947-5-3
Monitoring output OD
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Monitoring output OI
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Work area
Repeat accuracy R 10 %
Other
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures see operating instructions
Reliability values according to EN ISO 13849-1
Performance Level PL e
Category 4
PFHD 4.1 x 10 -9
Mission time 20 y