We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CTP-L1-AP-U-HA-AE-SH-123375
Part number
123375
Stock availability:
On request
If you are seeking Euchner CTP-L1-AP-U-HA-AE-SH-123375 123375, call FAMAGA, the world's main company of mechanized equipment. Our company has advanced for more than ten years - these are ages of experience, which are symbolized in the quality of outputs and personalseparate attention to each orderer. We praise everyone, who conspired with us - so, our regular clients pick up the most helpful purchase forms and discounts on the factory-made equipment market. Nowadays, there are more than 4500 such customers, and we constantly form new agreements. More than 700 contracts are concluded per day, because FAMAGA works all over the earth Germany, United Kingdom, Malaysia, Nepal, Lesotho, Syria, Seychelles, Russia, Laos, Palestine, Gambia, Poland, Myanmar, Papua New Guinea, Yemen, Ireland, Haiti, Togo, Nigeria, Romania, El Salvador, Malawi, Sudan, Cape Verde, Lithuania, Netherlands, Sierra Leone, Georgia, Equatorial Guinea, Dominica, North Korea, Morocco, Iran, Austria, Mauritania, The Gambia, Afghanistan, Guatemala, Slovakia, Indonesia, Cameroon, Burkina Faso, Eswatini, Sweden, Czech Republic, Botswana, China. A well-developed logistics network and a partnership network let us to ship our goods anywhere in the earth quickly without compromising product quality.
A particular source of repute for FAMAGA is its team members, each of whom contributes to common cause. We accept into our team only professionals, who already have experience in the range of manufacturing equipment.
All items from FAMAGA are ensured - we are responsible for the aftereffect of our work. At this moment, more than 10 million units of products have been supplied, and this amount is ascending every day. We are glad that users choose FAMAGA again and again, and we strive to make more exceptional and technologically innovative industrial equipment so as to stay on the top.
To inquire or make a request, get in touch with us or write a message to the online chat on our site. You can also direct a list of the needful equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.
CTP?L1 | Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle) |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
1 | IMP | Operating voltage of guard locking solenoid 24 V DC | VT | |
2 | - | n.c. | RD | |
3 | - | n.c. | GY | |
4 | FO1A | Safety output, channel 1 | RD/BU | |
5 | FO1B | Safety output, channel 2 | GN | |
6 | UB | Operating voltage of AP electronics 24 V DC | BU | |
7 | RST | Reset input | GY/PK | |
8 | OD | Door monitoring output | GN/WH | |
9 | OI | Diagnostic output | YE/WH | |
10 | OL | Guard locking monitoring output | GY/WH | |
11 | - | n.c. | BK | |
12 | FE | Function earth (must be connected to meet the EMC requirements) | GN/YE | |
13 | - | n.c. | PK | |
14 | - | n.c. | BN/GY | |
15 | - | n.c. | BN/YE | |
16 | - | n.c. | BN/GN | |
17 | - | n.c. | WH | |
18 | IMM | Operating voltage of guard locking solenoid 0 V | YE | |
19 | 0 V UB | Operating voltage of AP electronics 0 V | BN |
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,42 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | max.1 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M23, 19-pin, RC18 |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Test-pulse interval | min.100 ms |
Test pulses | max.0,3 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 2 A |
External (solenoid operating voltage IMP) | 0,5 ... 8 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 6 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
High U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
Low U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OL | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OI | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Repeat accuracy R | 10 % |
Additional feature | Escape release actuated by pushing |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |