We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CTP-L1-AR-M-HA-AE-SAB-123308
Part number
123308
Stock availability:
On request
If you are looking for Euchner CTP-L1-AR-M-HA-AE-SAB-123308 123308, make contact with FAMAGA, the world's chief retailer of streamlined equipment. Our company has functioned for more than ten years - these are ages of experience, which are symbolized in the quality of items and private attention to each purchaser. We praise everyone, who liased with us - so, our regular consumers procure the most desirable purchase forms and discounts on the factory-made equipment market. Today, there are more than 4500 such purchasers, and we constantly arrange new agreements. More than 600 affairs are settled per day, because FAMAGA supplies all over the globe Germany, United Kingdom, Norway, Bangladesh, Slovenia, Sierra Leone, Montenegro, Cameroon, Benin, Singapore, Russia, Kazakhstan, Oman, Uruguay, Israel, Burma, Iceland, Samoa, Malta, Guyana, Bhutan, Zambia, Ireland, Liechtenstein, Uzbekistan, Andorra, Gambia, Iraq, Vietnam, Sudan, Syria, Yemen, Czech Republic, Tonga, Turkey, Rwanda, Mozambique, Australia, Panama, Paraguay, Djibouti, Algeria, Madagascar, Slovakia, Laos. A well-shaped logistics link and a partnership network guide us to send our items anywhere in the planet immediately without disreputing product quality.
A special source of repute for FAMAGA is its personnel, each of whom contributes to common cause. We request into our team only professionals, who already have experience in the range of manufacturing equipment.
All merchandises from FAMAGA are verified - we are responsible for the aftereffect of our work. Nowadays, more than 10 million units of products have been delivered, and this amount is ascending every day. We are glad that consumers choose FAMAGA again and again, and we are glad to make more developed and technologically developed industrial equipment so as keep on top of it.
To request or order, phone us or send a message to the online chat on our site. You can also dispatch a list of the necessary equipment to the email of firm - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
CTP?L1 | Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle) |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
X 1.1 | FI1B | Enable input for channel 2 | WH | |
X 1.2 | UB | Operating voltage of AR electronics 24 V DC | BN | |
X 1.3 | FO1A | Safety output, channel 1 | GN | |
X 1.4 | FO1B | Safety output, channel 2 | YE | |
X 1.5 | OL | Guard locking monitoring output | GY | |
X 1.6 | FI1A | Enable input for channel 1 | PK | |
X 1.7 | 0 V UB | Operating voltage of AR electronics 0 V | BU | |
X 1.8 | RST | Reset input | RD | |
X 2.1 | IMM | Operating voltage of guard locking solenoid 0 V | BN | |
X 2.2 | OD | Door monitoring output | WH | |
X 2.3 | OI | Diagnostic output | BU | |
X 2.4 | IMP | Operating voltage of guard locking solenoid 24 V DC | BK | |
X 2.5 | - | n.c. | GY |
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,42 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP67 / IP69 / IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | 8 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5 and 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Test-pulse interval | min.140 ms |
Test pulses | max.1,0 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 2 A |
External (solenoid operating voltage IMP) | 0,5 ... 8 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 6 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
High U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
Low U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OL | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OI | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Repeat accuracy R | 10 % |
Additional feature | Escape release actuated by pushing |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |