We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
MGB-L1-ARA-AP7A1-M-R-121404
Part number
121404
Stock availability:
On request
If you are looking for Euchner MGB-L1-ARA-AP7A1-M-R-121404 121404, contact FAMAGA, the world's prime provider of factory-made equipment. Our company has worked for more than ten years - these are ages of experience, which are expressed in the quality of outcomes and private attention to each buyer. We appreciate everyone, who conspired with us - so, our regular consumers get the most favorable purchase terms and discounts on the factory-made equipment market. At this time, there are more than 4 thousand such clients, and we constantly compose new agreements. More than 600 proceedings are resolved per day, because FAMAGA works all over the world Germany, United Kingdom, Syria, Cyprus, Lesotho, Uzbekistan, Yemen, Cuba, Brazil, Austria, The Gambia, Fiji, Moldova, Ecuador, Benin, Zambia, Honduras, Eritrea, Swaziland, Kyrgyzstan, Malaysia, Nigeria, Monaco, El Salvador, Seychelles, Poland, The Bahamas, Morocco, Guyana, South Korea, Mauritania, Uganda, Guatemala, Albania, Lithuania, Nepal, Greece, China, Ireland, Uruguay, Serbia, Algeria, Comoros, Pakistan, Togo, Malta. A advanced logistics chains and a partnership network let us to send our items anywhere in the world with no delay without disreputing product quality.
A specific source of good name for FAMAGA is its workers, each of whom contributes to common cause. We request into our team only specialists, who already have experience in the field of industrial equipment.
All items from FAMAGA are verified - we are responsible for the result of our work. At the moment, more than 10 million units of products have been shipped, and this amount is ascending every day. We are happy that consumers choose FAMAGA again and again, and we are pleased to make more developed and technologically modern industrial equipment so as to stay on the top.
To inquire or place an order, phone us or write a message to the online chat on our site. You can also send a list of the required equipment to the email of firm - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
MGB-L1... | The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked). |
OD | ON when the door is closed |
OT | Bolt tongue inserted in the evaluation module |
OL | Guard locking solenoid in locked position |
OI | Diagnostics, there is a fault |
S1 | 2 positively driven NC contacts and 1 NO contact (e.g. monitoring contact), emergency stop with turn-to-reset, not illuminated |
S2 | 1 NO contact, illuminated |
S3 | 1 NO contact, illuminated |
S4 | Selector switch with 2 positions (form V, 90°). The switch latches in both positions |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN right |
Switching frequency | 0,25 Hz |
Connection | Cable entries M20x1.5 |
Guard locking principle | Closed-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connection cross-section | |
(Rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0,25 ... 0,75 mm? |
(Rigid/flexible) | 0,13 ... 1,5 mm? (AWG 24 ... AWG 16) |
(Rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0,25 ... 1,5 mm? |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.1 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Controls and indicators | |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Emergency stop | |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Belegungsschema | L1 |
Position 1 | |
Ausfuhrung | Emergency stop |
Einlegeschild | |
Extras | With auxiliary contact |
Farbe | |
Schaltelement | 2 pos. driven NC + 1NO |
Position 2 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | |
Schaltelement | 1NO |
Position 3 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | |
Schaltelement | 1NO |
Position 4 | |
Ausfuhrung | Selector switch |
Einlegeschild | |
Extras | |
Farbe | |
Schaltelement | 1NO |
Additional feature | Incl. cover set ID. No. 120344 |
Product version number | V3.0.3 |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Control of the guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.8 x 10-9 |
Emergency stop | |
B10D | |
Emergency stop | 0,065 x 106 |
Mission time | 20 y |