We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are questing Euchner MGB-L2H-ARA-L-121264 121264, connect FAMAGA, the world's major provider of industrial equipment. Our company has worked for more than ten years - these are ages of experience, which are depicted in the quality of goods and special attention to each client. We respect everyone, who cooperated with us - therefore, our regular customers get the most attractive purchase forms and discounts on the factory-made equipment market. Today, there are more than 3500 such buyers, and we constantly form new agreements. More than 700 contracts are concluded per day, because FAMAGA operates all over the globe Germany, United Kingdom, Spain, Cape Verde, Guinea, Tunisia, East Timor, Romania, Libya, Australia, United Arab Emirates, Czech Republic, Tonga, Poland, Slovakia, The Bahamas, Russia, Mauritius, Senegal, Djibouti, Argentina, The Gambia, Cyprus, Swaziland, Brunei, Georgia, Zimbabwe, Jamaica, Indonesia, Afghanistan, Guyana, Comoros, Egypt, Chile, Haiti, Hungary, Pakistan, Seychelles, Bosnia and Herzegovina, Ireland, Croatia, Kuwait, Burkina Faso, Finland, Ukraine. A well-elaborated logistics system and a partnership network let us to deliver our items anywhere in the globe promptly without compromising product quality.
A particular source of pride for FAMAGA is its personnel, each of whom contributes to our work. We invite into our team only specialists, who already have experience in the range of manufacturing equipment.
All spare parts from FAMAGA are guaranteed - we are responsible for the cause of our work. Now, more than 10 million units of products have been supplied, and this amount is amounting every day. We are pleased that purchasers choose FAMAGA again and again, and we strive to make more exceptional and technologically innovative industrial equipment so as not to lower the bar.
To consult or book, phone us or write a message to the online chat on our site. You can also send a list of the desirable equipment to the email of corporation - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle, electrically locked). |
OD | ON when the door is closed |
OT | Bolt tongue inserted in the evaluation module |
OL | Guard locking solenoid in locked position |
OI | Diagnostics, there is a fault |
S1 | 2 positively driven NC contacts and 1 NO contact (e.g. monitoring contact), emergency stop with turn-to-reset, not illuminated |
S2 | 1 NO contact, illuminated |
S3 | 1 NO contact, illuminated |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN left |
Switching frequency | 0,25 Hz |
Connection | Cable entries M20x1.5 |
Guard locking principle | Open-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connection cross-section | |
(Rigid/flexible) | 0,13 ... 1,5 mm? (AWG 24 ... AWG 16) |
(Rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0,25 ... 1,5 mm? |
(Rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0,25 ... 0,75 mm? |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Emergency stop | |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Safety outputs FO1A, FO1B | |
Test pulses | max.1 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Controls and indicators | |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Additional feature | Incl. cover set ID. No. 120344 |
Product version number | V3.0.3 |
Slide-in label | 2 pcs. without marking |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Emergency stop | |
B10D | |
Emergency stop | 0,065 x 106 |
Mission time | 20 y |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,00 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP65 |
Installation orientation | Door hinge DIN left |
Product version number | V3.0.0 |