We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
MGB-L1-ARA-AI2A1-S6-R-119923
Part number
119923
Stock availability:
On request
If you are seeking Euchner MGB-L1-ARA-AI2A1-S6-R-119923 119923, communicate with FAMAGA, the world's the best provider of manufacturing equipment. Our company has existed for more than ten years - these are ages of experience, which are represented in the quality of goods and special attention to each buyer. We esteem everyone, who cooperated with us - hence, our regular clients get the most beneficial purchase terms and discounts on the factory-made equipment market. At present, there are more than 3500 such buyers, and we constantly sign new agreements. More than 600 contracts are concluded per day, because FAMAGA supplies all over the globe Germany, United Kingdom, Cyprus, Russia, Iran, Honduras, Cuba, Suriname, Ireland, Cameroon, Oman, Luxembourg, Eritrea, Malaysia, Netherlands, China, Lebanon, Egypt, Ghana, Estonia, Belarus, Vietnam, Namibia, Philippines, Japan, Guyana, Uruguay, Fiji, Czech Republic, South Korea, Costa Rica, Burkina Faso, Hungary, Syria, Argentina, Serbia, Mauritius, Mauritania, Albania, Greece, Seychelles, Belize, Guatemala, Tonga, Morocco, Kyrgyzstan, Botswana, Cape Verde. A well-elaborated logistics chains and a partnership network help us to ship our elements anywhere in the globe quickly without discrediting product quality.
A specific source of repute for FAMAGA is its employees, each of whom contributes to our work. We invite into our team only professionals, who already have experience in the sphere of manufacturing equipment.
All goods from FAMAGA are ensured - we are responsible for the result of our work. Now, more than 10 million units of products have been delivered, and this amount is growing every day. We are pleased that users choose FAMAGA again and again, and we are eager to make more developed and technologically innovative industrial equipment so as keep on top of it.
To inquire or order, phone us or send a message to the online chat on our site. You can also forward a list of the desirable equipment to the email of firm - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
MGB-L1... | The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked). |
OD | ON when the door is closed |
OT | Bolt tongue inserted in the evaluation module |
OL | Guard locking solenoid in locked position |
OI | Diagnostics, there is a fault |
S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
S2 | 1 NO contact, green, illuminated |
S3 | 1 NO contact, white, illuminated |
S4 | 1 NO contact, blue, illuminated |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN right |
Switching frequency | 0,25 Hz |
Connection | Plug connector RC26 |
Guard locking principle | Closed-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.1 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Controls and indicators | |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Emergency stop | |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Belegungsschema | L1 |
Position 1 | |
Ausfuhrung | Emergency stop |
Einlegeschild | |
Extras | |
Farbe | |
Schaltelement | 2 pos. driven NC |
Position 2 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | Green |
Schaltelement | 1NO |
Position 3 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | white |
Schaltelement | 1NO |
Position 4 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | Blue |
Schaltelement | 1NO |
Product version number | V3.0.3 |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Control of the guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.8 x 10-9 |
Emergency stop | |
B10D | |
Emergency stop | 0,065 x 106 |
Mission time | 20 y |