We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
MGB-L2-ARA-AA1A1-S1-R-109776
Part number
109776
Stock availability:
On request
If you are seeking Euchner MGB-L2-ARA-AA1A1-S1-R-109776 109776, connect FAMAGA, the world's primary distributor of mechanized equipment. Our company has advanced for more than ten years - these are years of experience, which are outlined in the quality of outcomes and special attention to each customer. We understand everyone, who conspired with us - so, our regular buyers bring in the most convenient purchase terms and discounts on the factory-made equipment market. At present, there are more than 4500 such purchasers, and we constantly compose new agreements. More than 600 purchases are terminated per day, because FAMAGA supplies all over the world Germany, United Kingdom, Turkmenistan, Sudan, Senegal, Slovakia, Namibia, Uzbekistan, Estonia, Bahamas, The Bahamas, Suriname, Hungary, Bhutan, Uganda, Czech Republic, Malawi, Canada, Mali, Egypt, Saudi Arabia, Iraq, Burundi, Uruguay, Japan, Kenya, Kazakhstan, Moldova, Montenegro, Poland, Israel, Antigua and Barbuda, Switzerland, Libya, Djibouti, North Korea, Denmark, Zambia, Yemen, Kiribati, Syria, Kyrgyzstan, Lithuania, Ukraine, Croatia. A advanced logistics series and a partnership network assist us to ship our goods anywhere in the planet with no delay without discrediting product quality.
A specific source of repute for FAMAGA is its workers, each of whom contributes to common cause. We invite into our team only specialists, who already have experience in the field of manufacturing equipment.
All outputs from FAMAGA are assured - we are responsible for the aftereffect of our work. At the moment, more than 10 million units of products have been delivered, and this amount is rising every day. We are glad that customers choose FAMAGA again and again, and we are pleased to make more developed and technologically advanced industrial equipment so as keep on top of it.
To request or order, phone us or write to the online chat on our site. You can also send a list of the necessary equipment to the email of firm - we will contact you ourselves with a made commercial proposal from FAMAGA.
MGB-L1... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle, electrically locked). |
OD | ON when the door is closed |
OT | Bolt tongue inserted in the evaluation module |
OL | Guard locking solenoid in locked position |
OI | Diagnostics, there is a fault |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN right |
Switching frequency | 0,25 Hz |
Connection | Plug connector RC18 |
Guard locking principle | Open-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.1 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Product version number | V3.0.3 |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Mission time | 20 y |