MGB-L1B-PNA-R-159090 Euchner 159090
 MGB-L1B-PNA-R-159090 Euchner 159090

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

MGB-L1B-PNA-R-159090 159090 Euchner

Manufacturer

Euchner

Country

Germany

Name

MGB-L1B-PNA-R-159090

Part number

159090

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications MGB-L1B-PNA-R-159090 159090

If you are inspecting Euchner MGB-L1B-PNA-R-159090 159090, call FAMAGA, the world's dominant retailer of manufacturing equipment. Our company has lasted for more than ten years - these are ages of experience, which are outlined in the quality of items and private attention to each consumer. We esteem everyone, who collaborated with us - so, our regular consumers bring in the most attractive purchase terms and discounts on the factory-made equipment market. At present, there are more than 4 thousand such consumers, and we constantly make new agreements. More than 600 agreements are achieved per day, because FAMAGA works all over the planet . A well-shaped logistics chains and a partnership network help us to dispatch our elements anywhere in the planet with no delay without disreputing product quality.

A special source of good name for FAMAGA is its team members, each of whom contributes to common cause. We call into our team only experts, who already have experience in the sphere of manufacturing equipment.

All merchandises from FAMAGA are ensured - we are responsible for the result of our work. Now, more than 10 million units of products have been delivered, and this amount is ascending every day. We are happy that users choose FAMAGA again and again, and we are pleased to make more developed and technologically innovative industrial equipment so as to stay on the top.

To inquire or order, phone us or write to the online chat on our site. You can also direct a list of the necessary equipment to the email of firm - we will contact you ourselves with a worked out commercial proposal from FAMAGA.

Features MGB-L1B-PNA-R-159090 159090

  • Guard locking with guard lock monitoring
  • Emergency stop according to ISO 13850, illuminated
  • Four illuminated pushbuttons
  • including adhesive labels
  • Connection via 7/8 and M12 plugs
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
  • Unicode
Profinet connection 7/8 plugs according to ANSI/B93.55M-1981 and M12 plugs (d-coded) according to IEC 61076-2-101 Profinet RT switch Point-to-point topology network structure due to integrated RT switch. Flexible use as interlocking or guard locking By means of the corresponding evaluation of the safe device data by the control system, use can be as either interlocking or guard locking (with or without monitoring). Illuminated emergency stop Emergency stop with illumination that can be controlled as required. Dimension drawing Dimension drawing Technical dataApprovals Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 3,1 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP54
Resilience to vibration In accordance with EN 60947-5-3
Mechanical life 1 x 106
In case of use as door stop, and 1 Joule impact energy 0,1 x 106
Installation orientation Door hinge DIN right
Reaction time
Emergency stop / machine stop max.250 ms Switch-off time
Guard locking max.550 ms Switch-off time
Door position max.550 ms Switch-off time
Bolt position max.550 ms Switch-off time
Switching frequency 0,25 Hz
Connection
7/8 Power
7/8 Power
Acc. to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e M12 D-coded, screened
M12 D-coded, screened
Guard locking principle Closed-circuit current principle
Locking force FZh 2000 N
Electrical connection ratings
Current consumption max.500 mA
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0,5 kV
Maximum feed-in current in the connection block
X1, X2 max.4000 mA
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
Degree of contamination (external, according to EN 60947-1) 3
Connecting cable
Ethernet Profinet I/O cable, at least cat. 5e
Safety class III
Transponder coding Unicode
Power supply X1
Operating voltage DC
L1 24 V DC -15% ... 10%
Auxiliary voltage DC
L2 24 V DC -15% ... +10%
Fusing
external min.1 A Slow blow
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... 10%
Auxiliary voltage DC
L2 24 V DC -15% ... +10%
Work area
Assured switch-off distance Sar max.65 mm
Interface, bus
Data interface
Data protocol
Bus protocol Profinet (IEC 61158 type 10)
Safety protocol Profisafe (IEC 61784-3-3)
Controls and indicators
Belegungsschema B1
Belegungsschema L1
Position 1
Ausfuhrung Emergency stop illuminated
Einlegeschild
Extras
Farbe
Schaltelement 2 pos. driven NC
Position 90
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe
Schaltelement 1NO
Position 92
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe
Schaltelement 1NO
Position 93
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe
Schaltelement 1NO
Position 95
Ausfuhrung Button
Einlegeschild
Extras
Farbe
Schaltelement 1NO
Other
Additional feature Incl. cover set ID. No. 120344
Product version number V3.30.10
Slide-in label
CYCLE STOP / UNLOCK
PARO DE CICLO / DESBLOQUEAR
ZYKLUS STOP / ENTRIEGELN
LOCK
BLOQUEAR
VERRIEGELN
EMERGENCY RELEASE
LIBERAR PARO DE EMERGENCIA
NOTENTRIEGELUNG
AUTOMATIK START
ARRANQUE AUTOMATICO
AUTO START
RESTABLECER
Reset
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position
Category 4
Performance Level PL e
PFHD 4.07 x 10-8
Diagnostic Coverage (DC) 99
Control of the guard locking
Category 4
Performance Level PL e
PFHD 3.91 x 10-8
Emergency stop
B10D
Emergency stop 0.1 x 106
Emergency-stop evaluation
Category 4
Performance Level PL e
PFHD 4.1 x 10-8
Safety Integrity Level SIL 3 (EN 62061:2005)
Mission time 20