Manufacturer
Euchner
Country
Germany
Name
CTP-L1-AP-U-HA-AES-SA-157112
Part number
157112
Stock availability:
On request
If you are seeking Euchner CTP-L1-AP-U-HA-AES-SA-157112 157112, contact FAMAGA, the world's chief retailer of streamlined equipment. Our company has lasted for more than ten years - these are cycles of experience, which are expressed in the quality of products and particular attention to each user. We admire everyone, who liased with us - therefore, our regular purchasers bring in the most beneficial purchase conditions and discounts on the manufacturing equipment market. At this moment, there are more than 4500 such purchasers, and we constantly compose new agreements. More than 750 agreements are achieved per day, because FAMAGA operates all over the earth Germany, United Kingdom, Cameroon, Zambia, Mali, Portugal, Vietnam, Iraq, Macedonia, The Bahamas, Tanzania, Malawi, Colombia, Turkmenistan, Comoros, Greece, China, El Salvador, Guinea, Montenegro, Rwanda, Poland, Algeria, Tajikistan, Austria, Fiji, Uzbekistan, Moldova, Argentina, Mauritius, Kazakhstan, North Korea, Ghana, Uganda, Mauritania, Antigua and Barbuda, Peru, Laos, Belize, Eswatini, Iran, Croatia, Hungary, Andorra. A well-shaped logistics series and a partnership network assist us to ship our goods anywhere in the earth immediately without undermining product quality.
A special source of repute for FAMAGA is its workers, each of whom contributes to common cause. We call into our team only experts, who already have experience in the direction of machine made streamlined equipment.
All outcomes from FAMAGA are affirmed - we are responsible for the aftereffect of our work. Now, more than 10 million units of products have been provided, and this quantity is increasing every day. We are glad that clients choose FAMAGA again and again, and we are pleased to make more progressive and technologically advanced industrial equipment so as not to lower the bar.
To request or make a request, phone us or write to the online chat on our site. You can also send a list of the needful equipment to the email of organization - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
CTP?L1 | Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle) |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
1 | IMP | Operating voltage of guard locking solenoid 24 V DC | WH | |
2 | UB | Operating voltage of AP electronics 24 V DC | BN | |
3 | FO1A | Safety output, channel 1 | GN | |
4 | FO1B | Safety output, channel 2 | YE | |
5 | OI | Diagnostic output | GY | |
6 | OD | Door monitoring output | PK | |
7 | 0 V UB | Operating voltage of AP electronics 0 V | BU | |
8 | IMM | Operating voltage of guard locking solenoid 0 V | RD |
Housing material | |
Metal material | Stainless steel |
Safety switch housing | Fiber glass reinforced thermoplastic |
Actuating button | POM-C |
Weight | |
Net | 0,53 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP67 / IP69 / IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | max.1 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M12, 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Test-pulse interval | min.100 ms |
Test pulses | max.0,3 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 2 A |
External (solenoid operating voltage IMP) | 0,5 ... 8 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 6 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OI | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Repeat accuracy R | 10 % |
Additional feature | Escape release actuated by pushing |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |