CTP-L1-AP-U-HA-AEE-SH-137342 Euchner 137342
 CTP-L1-AP-U-HA-AEE-SH-137342 Euchner 137342

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

CTP-L1-AP-U-HA-AEE-SH-137342 137342 Euchner

Manufacturer

Euchner

Country

Germany

Name

CTP-L1-AP-U-HA-AEE-SH-137342

Part number

137342

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications CTP-L1-AP-U-HA-AEE-SH-137342 137342

If you are pursuing Euchner CTP-L1-AP-U-HA-AEE-SH-137342 137342, connect FAMAGA, the world's major distributor of manufacturing equipment. Our company has progressed for more than ten years - these are cycles of experience, which are depicted in the quality of goods and individual attention to each buyer. We esteem everyone, who worked with us - therefore, our regular customers accept the most attractive purchase terms and discounts on the manufacturing equipment market. At this moment, there are more than 3500 such clients, and we constantly arrange new agreements. More than 600 agreements are achieved per day, because FAMAGA operates all over the globe . A advanced logistics chains and a partnership network help us to dispatch our goods anywhere in the globe with no delay without damaging product quality.

A specific source of dignity for FAMAGA is its personnel, each of whom contributes to our work. We propose into our team only experts, who already have experience in the sphere of machine made streamlined equipment.

All spare parts from FAMAGA are guaranteed - we are responsible for the result of our work. Now, more than 10 million units of products have been delivered, and this quantity is amounting every day. We are pleased that buyers choose FAMAGA again and again, and we are glad to make more developed and technologically advanced industrial equipment so as not to lower the bar.

To consult or order, phone us or send a message to the online chat on our site. You can also send a list of the desirable equipment to the email of firm - we will contact you ourselves with a worked out commercial proposal from FAMAGA.

Features CTP-L1-AP-U-HA-AEE-SH-137342 137342

  • Safety switch with guard locking and integrated evaluation electronics
  • Short circuit monitoring
  • Two safety outputs (semiconductor outputs)
  • Up to category 4/PL e according to EN ISO 13849-1
  • Two pushbuttons (illuminated)
  • With plug connector M23
  • Unicode
  • Door monitoring output
  • With escape release
  • Approach directions A, B and C (delivery state)
Approach direction Horizontal Can be adjusted in 90° steps Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Guard locking type
CTP?L1Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle)
Lens set The color of the pushbutton can be selected using the lens set included (five colors). Item no.: 120344 (see Accessories) Connector assignment
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connecting cable
1 IMP Operating voltage of guard locking solenoid 24 V DC VT
2 - Not used RD
3 - Not used GY
4 FO1A Safety output, channel 1 RD/BU
5 FO1B Safety output, channel 2 GN
6 UB Operating voltage of AP electronics, controls and indicators 24 V DC BU
7 RST Reset input GY/PK
8 OD Door monitoring output GN/WH
9 OI Diagnostic output YE/WH
10 OL Guard locking monitoring output GY/WH
11 - Not used BK
12 FE Function earth (must be connected to meet the EMC requirements) GN/YE
13 IMM Operating voltage of guard locking solenoid 0 V PK
14 - Not used BN/GY
15 S2 Pushbutton 2 (illuminated) BN/YE
16 H2 LED 2 BN/GN
17 S3 Pushbutton 3 (illuminated) WH
18 H3 LED 3 YE
19 0 V UB Operating voltage of AP electronics, controls and indicators 0 V BN
Housing material
Switch head cover Die-cast zinc
Safety switch housing Fiber glass reinforced thermoplastic
Weight
Net 0,5 kg
Ambient temperature
At UB = 24V DC -20 ... +55 °C
Degree of protection IP65
Resilience to vibration In acc. with EN IEC 60947-5-3
Mechanical life 1 x 106
Installation orientation Any
Ready delay max.1 s
Switching frequency max.0,5 Hz
Connection 1 plug connector M23, 19-pin, RC18
Approach speed 20 m/min
Guard locking principle Closed-circuit current principle
Locking force Fmax 3900 N
Locking force FZh 3000 N
Retention force 20 N
Extraction force 20 N
Actuating force 10 N
Overtravel 5 mm
Electrical connection ratings
Test-pulse interval min.100 ms
Test pulses max.0,3 ms
Operating voltage DC
UUB 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Current consumption
IIMP 400 mA
IUB 40 mA
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Fusing
External (operating voltage UB) 0,25 ... 2 A
External (solenoid operating voltage IMP) 0,5 ... 8 A
Rated insulation voltage Ui max.50 V
Rated impulse withstand voltage Uimp max.0,5 kV
Power consumption 6 W
EMC protection requirements In acc. with EN IEC 60947-5-3
Solenoid duty cycle 100 %
Degree of contamination (external, according to EN 60947-1) 3
Safety class
EN IEC 61140 III
Switching load
According to UL 24V DC, class 2
Safety outputs FO1A / FO1B
Type of output 2 semiconductor outputs, p-switching, short circuit-proof
Switching current
Per safety output FO1A / FO1B 1 ... 150 mA
Output voltage
High U(FO1A) / U(FO1B) UB-1,5 ... UB V DC
Low U(FO1A) / U(FO1B) 0 ... 1 V DC
Off-state current Ir max.0,25 mA
Switch-on time max.400 ms
Discrepancy time
Both safety outputs max.10 ms In acc. with EN IEC 60947-5-3
Monitoring output OL
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Monitoring output OD
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Monitoring output OI
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Controls and indicators
Operating voltage UB V
Operating current 1 ... 50 mA
Power supply
LED 24 V
Current consumption
LED 10 mA
Work area
Repeat accuracy R 10 %
Controls and indicators
Position 2
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe
Schaltelement 1NO
Position 3
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe
Schaltelement 1NO
Other
Additional feature
Escape release actuated by pushing
Incl. cover set ID. No. 120344
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures see operating instructions
Reliability values according to EN ISO 13849-1
Performance Level PL e
Category 4
PFHD 4.1 x 10 -9
Mission time 20 y