We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CTP-L1-AP-U-HA-AEE-SH-137342
Part number
137342
Stock availability:
On request
If you are pursuing Euchner CTP-L1-AP-U-HA-AEE-SH-137342 137342, connect FAMAGA, the world's major distributor of manufacturing equipment. Our company has progressed for more than ten years - these are cycles of experience, which are depicted in the quality of goods and individual attention to each buyer. We esteem everyone, who worked with us - therefore, our regular customers accept the most attractive purchase terms and discounts on the manufacturing equipment market. At this moment, there are more than 3500 such clients, and we constantly arrange new agreements. More than 600 agreements are achieved per day, because FAMAGA operates all over the globe Germany, United Kingdom, Latvia, Senegal, Montenegro, Guatemala, Chad, Panama, Ecuador, Comoros, Kyrgyzstan, Djibouti, Tanzania, Singapore, Belgium, Malaysia, Bangladesh, Iraq, United Arab Emirates, Slovakia, Norway, Cameroon, Azerbaijan, Angola, Botswana, Andorra, United States, Macedonia, Thailand, Nigeria, Belize, Iran, Chile, Switzerland, Turkey, Jamaica, Malta, Brunei, Equatorial Guinea, Israel, Rwanda, Uganda, Zambia, Costa Rica. A advanced logistics chains and a partnership network help us to dispatch our goods anywhere in the globe with no delay without damaging product quality.
A specific source of dignity for FAMAGA is its personnel, each of whom contributes to our work. We propose into our team only experts, who already have experience in the sphere of machine made streamlined equipment.
All spare parts from FAMAGA are guaranteed - we are responsible for the result of our work. Now, more than 10 million units of products have been delivered, and this quantity is amounting every day. We are pleased that buyers choose FAMAGA again and again, and we are glad to make more developed and technologically advanced industrial equipment so as not to lower the bar.
To consult or order, phone us or send a message to the online chat on our site. You can also send a list of the desirable equipment to the email of firm - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
CTP?L1 | Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle) |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
1 | IMP | Operating voltage of guard locking solenoid 24 V DC | VT | |
2 | - | Not used | RD | |
3 | - | Not used | GY | |
4 | FO1A | Safety output, channel 1 | RD/BU | |
5 | FO1B | Safety output, channel 2 | GN | |
6 | UB | Operating voltage of AP electronics, controls and indicators 24 V DC | BU | |
7 | RST | Reset input | GY/PK | |
8 | OD | Door monitoring output | GN/WH | |
9 | OI | Diagnostic output | YE/WH | |
10 | OL | Guard locking monitoring output | GY/WH | |
11 | - | Not used | BK | |
12 | FE | Function earth (must be connected to meet the EMC requirements) | GN/YE | |
13 | IMM | Operating voltage of guard locking solenoid 0 V | PK | |
14 | - | Not used | BN/GY | |
15 | S2 | Pushbutton 2 (illuminated) | BN/YE | |
16 | H2 | LED 2 | BN/GN | |
17 | S3 | Pushbutton 3 (illuminated) | WH | |
18 | H3 | LED 3 | YE | |
19 | 0 V UB | Operating voltage of AP electronics, controls and indicators 0 V | BN |
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,5 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP65 |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | max.1 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M23, 19-pin, RC18 |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Test-pulse interval | min.100 ms |
Test pulses | max.0,3 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IIMP | 400 mA |
IUB | 40 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 2 A |
External (solenoid operating voltage IMP) | 0,5 ... 8 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 6 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
High U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
Low U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OL | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OI | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Controls and indicators | |
Operating voltage | UB V |
Operating current | 1 ... 50 mA |
Power supply | |
LED | 24 V |
Current consumption | |
LED | 10 mA |
Repeat accuracy R | 10 % |
Position 2 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | |
Schaltelement | 1NO |
Position 3 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | |
Schaltelement | 1NO |
Additional feature | |
Escape release actuated by pushing | |
Incl. cover set ID. No. 120344 | |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |