We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CTP-L1-AR-U-HA-AEE-SH-137164
Part number
137164
Stock availability:
On request
If you are looking for Euchner CTP-L1-AR-U-HA-AEE-SH-137164 137164, contact FAMAGA, the world's the best vendor of factory-made equipment. Our company has advanced for more than ten years - these are cycles of experience, which are expressed in the quality of spare parts and special attention to each consumer. We cherish everyone, who joined with us - therefore, our regular buyers procure the most acceptable purchase terms and discounts on the factory-made equipment market. At this time, there are more than 3500 such buyers, and we constantly make new agreements. More than 750 agreements are achieved per day, because FAMAGA operates all over the globe Germany, United Kingdom, Montenegro, Swaziland, Brunei, Slovakia, Monaco, Tanzania, El Salvador, Austria, Seychelles, India, Switzerland, Malawi, Honduras, Andorra, Mauritius, Tajikistan, Norway, Belarus, Bolivia, Croatia, Russia, Antigua and Barbuda, Argentina, Panama, Brazil, China, Nepal, Serbia, Angola, Morocco, Burkina Faso, Ukraine, Kuwait, Malta, Malaysia, Turkey, Haiti, Poland, Mozambique, East Timor, Samoa, Iraq. A well-elaborated logistics bond and a partnership network help us to send our units anywhere in the globe immediately without disreputing product quality.
A specific source of honor for FAMAGA is its workers, each of whom contributes to our work. We invite into our team only experts, who already have experience in the direction of manufacturing equipment.
All outcomes from FAMAGA are assured - we are responsible for the result of our work. At this moment, more than 10 million units of products have been provided, and this amount is increasing every day. We are pleased that clients choose FAMAGA again and again, and we are happy to make more progressive and technologically innovative industrial equipment so as not to lower the bar.
To ask a question or order, get in touch with us or send a message to the online chat on our site. You can also send a list of the desirable equipment to the email of firm - we will contact you ourselves with a made commercial proposal from FAMAGA.
CTP?L1 | Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle) |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
1 | IMP | Operating voltage of guard locking solenoid 24 V DC | VT | |
2 | FI1A | Enable input for channel 1 | RD | |
3 | FI1B | Enable input for channel 2 | GY | |
4 | FO1A | Safety output, channel 1 | RD/BU | |
5 | FO1B | Safety output, channel 2 | GN | |
6 | UB | Operating voltage of AR electronics, controls and indicators 24 V DC | BU | |
7 | RST | Reset input | GY/PK | |
8 | OD | Door monitoring output | GN/WH | |
9 | OI | Diagnostic output | YE/WH | |
10 | S1.A1 | Emergency stop (channel A) | GY/WH | |
11 | S1.A2 | Emergency stop (channel A) | BK | |
12 | FE | Function earth (must be connected to meet the EMC requirements) | GN/YE | |
13 | S1.B1 | Emergency stop (channel B) | PK | |
14 | S1.B2 | Emergency stop (channel B) | BN/GY | |
15 | S2 | Pushbutton 2 (illuminated) | BN/YE | |
16 | H2 | LED 2 | BN/GN | |
17 | S3 | Pushbutton 3 (illuminated) | WH | |
18 | H3 | LED 3 | YE | |
19 | 0 V | Operating voltage of AR electronics, controls and indicators 0 V/guard locking solenoid 0 V | BN |
Housing material | |
Safety switch housing | Fiber glass reinforced thermoplastic |
Switch head cover | Die-cast zinc |
Weight | |
Net | 0,57 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP65 |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | 8 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M23, 19-pin, RC18 |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Test-pulse interval | min.140 ms |
Test pulses | max.1,0 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 2 A |
External (solenoid operating voltage IMP) | 0,5 ... 8 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 6 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
High U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
Low U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OI | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Controls and indicators | |
Operating voltage | UB V |
Operating current | 1 ... 50 mA |
Power supply | |
LED | 24 V |
Current consumption | |
LED | 10 mA |
Emergency stop | |
Operating voltage | 5 ... 24 V |
Operating current | 1 ... 100 mA |
Repeat accuracy R | 10 % |
Position 1 | |
Ausfuhrung | Emergency stop |
Einlegeschild | |
Extras | |
Farbe | |
Schaltelement | 2 pos. driven NC |
Position 2 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | |
Schaltelement | 1NO |
Position 3 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | |
Schaltelement | 1NO |
Additional feature | |
Incl. cover set ID. No. 120344 | |
Escape release actuated by pushing | |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Emergency stop | |
B10D | 0,065 x 106 |
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |