CTP-L1-AR-U-HA-AEE-SH-137164 Euchner 137164
 CTP-L1-AR-U-HA-AEE-SH-137164 Euchner 137164

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

CTP-L1-AR-U-HA-AEE-SH-137164 137164 Euchner

Manufacturer

Euchner

Country

Germany

Name

CTP-L1-AR-U-HA-AEE-SH-137164

Part number

137164

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications CTP-L1-AR-U-HA-AEE-SH-137164 137164

If you are looking for Euchner CTP-L1-AR-U-HA-AEE-SH-137164 137164, contact FAMAGA, the world's the best vendor of factory-made equipment. Our company has advanced for more than ten years - these are cycles of experience, which are expressed in the quality of spare parts and special attention to each consumer. We cherish everyone, who joined with us - therefore, our regular buyers procure the most acceptable purchase terms and discounts on the factory-made equipment market. At this time, there are more than 3500 such buyers, and we constantly make new agreements. More than 750 agreements are achieved per day, because FAMAGA operates all over the globe . A well-elaborated logistics bond and a partnership network help us to send our units anywhere in the globe immediately without disreputing product quality.

A specific source of honor for FAMAGA is its workers, each of whom contributes to our work. We invite into our team only experts, who already have experience in the direction of manufacturing equipment.

All outcomes from FAMAGA are assured - we are responsible for the result of our work. At this moment, more than 10 million units of products have been provided, and this amount is increasing every day. We are pleased that clients choose FAMAGA again and again, and we are happy to make more progressive and technologically innovative industrial equipment so as not to lower the bar.

To ask a question or order, get in touch with us or send a message to the online chat on our site. You can also send a list of the desirable equipment to the email of firm - we will contact you ourselves with a made commercial proposal from FAMAGA.

Features CTP-L1-AR-U-HA-AEE-SH-137164 137164

  • Safety switch with guard locking and integrated evaluation electronics
  • Up to 20 switches in series
  • Short circuit monitoring
  • Two safety outputs (semiconductor outputs)
  • Up to category 4/PL e according to EN ISO 13849-1
  • Emergency stop
  • Two pushbuttons (illuminated)
  • With plug connector M23
  • Unicode
  • Door monitoring output
  • With escape release
  • Approach directions A, B and C (delivery state)
Approach direction Horizontal Can be adjusted in 90° steps Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Guard locking type
CTP?L1Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle)
Escape release This is used for manual release of guard locking from the danger zone without tools. Lens set The color of the pushbutton can be selected using the lens set included (five colors). Item no.: 120344 (see Accessories) Connector assignment
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connecting cable
1 IMP Operating voltage of guard locking solenoid 24 V DC VT
2 FI1A Enable input for channel 1 RD
3 FI1B Enable input for channel 2 GY
4 FO1A Safety output, channel 1 RD/BU
5 FO1B Safety output, channel 2 GN
6 UB Operating voltage of AR electronics, controls and indicators 24 V DC BU
7 RST Reset input GY/PK
8 OD Door monitoring output GN/WH
9 OI Diagnostic output YE/WH
10 S1.A1 Emergency stop (channel A) GY/WH
11 S1.A2 Emergency stop (channel A) BK
12 FE Function earth (must be connected to meet the EMC requirements) GN/YE
13 S1.B1 Emergency stop (channel B) PK
14 S1.B2 Emergency stop (channel B) BN/GY
15 S2 Pushbutton 2 (illuminated) BN/YE
16 H2 LED 2 BN/GN
17 S3 Pushbutton 3 (illuminated) WH
18 H3 LED 3 YE
19 0 V Operating voltage of AR electronics, controls and indicators 0 V/guard locking solenoid 0 V BN
Housing material
Safety switch housing Fiber glass reinforced thermoplastic
Switch head cover Die-cast zinc
Weight
Net 0,57 kg
Ambient temperature
At UB = 24V DC -20 ... +55 °C
Degree of protection IP65
Resilience to vibration In acc. with EN IEC 60947-5-3
Mechanical life 1 x 106
Installation orientation Any
Ready delay 8 s
Switching frequency max.0,5 Hz
Connection 1 plug connector M23, 19-pin, RC18
Approach speed 20 m/min
Guard locking principle Closed-circuit current principle
Locking force Fmax 3900 N
Locking force FZh 3000 N
Retention force 20 N
Extraction force 20 N
Actuating force 10 N
Overtravel 5 mm
Electrical connection ratings
Test-pulse interval min.140 ms
Test pulses max.1,0 ms
Operating voltage DC
UUB 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Current consumption
IUB 40 mA
IIMP 400 mA
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Fusing
External (operating voltage UB) 0,25 ... 2 A
External (solenoid operating voltage IMP) 0,5 ... 8 A
Rated insulation voltage Ui max.50 V
Rated impulse withstand voltage Uimp max.0,5 kV
Power consumption 6 W
EMC protection requirements In acc. with EN IEC 60947-5-3
Solenoid duty cycle 100 %
Degree of contamination (external, according to EN 60947-1) 3
Safety class
EN IEC 61140 III
Risk time according to EN 60947-5-3
Delay per device 5 ms
Single device max.260 ms
Switching load
According to UL 24V DC, class 2
Safety outputs FO1A / FO1B
Type of output 2 semiconductor outputs, p-switching, short circuit-proof
Switching current
Per safety output FO1A / FO1B 1 ... 150 mA
Output voltage
High U(FO1A) / U(FO1B) UB-1,5 ... UB V DC
Low U(FO1A) / U(FO1B) 0 ... 1 V DC
Off-state current Ir max.0,25 mA
Switch-on time max.400 ms
Discrepancy time
Both safety outputs max.10 ms In acc. with EN IEC 60947-5-3
Monitoring output OD
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Monitoring output OI
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Controls and indicators
Operating voltage UB V
Operating current 1 ... 50 mA
Power supply
LED 24 V
Current consumption
LED 10 mA
Emergency stop
Operating voltage 5 ... 24 V
Operating current 1 ... 100 mA
Work area
Repeat accuracy R 10 %
Controls and indicators
Position 1
Ausfuhrung Emergency stop
Einlegeschild
Extras
Farbe
Schaltelement 2 pos. driven NC
Position 2
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe
Schaltelement 1NO
Position 3
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe
Schaltelement 1NO
Other
Additional feature
Incl. cover set ID. No. 120344
Escape release actuated by pushing
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures see operating instructions
Reliability values according to EN ISO 13849-1
Emergency stop
B10D 0,065 x 106
Performance Level PL e
Category 4
PFHD 4.1 x 10 -9
Mission time 20 y