We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CTP-L1-AP-U-HA-AZ-SA-EX-136675
Part number
136675
Description
Sicherheitsschalter 24VAC/DC
Stock availability:
On request
If you are questing Euchner CTP-L1-AP-U-HA-AZ-SA-EX-136675 136675, call FAMAGA, the world's central company of mechanized equipment. Our company has functioned for more than ten years - these are ages of experience, which are symbolized in the quality of outputs and personalseparate attention to each orderer. We cherish everyone, who collaborated with us - so, our regular buyers pick up the most flexible purchase conditions and discounts on the factory-made equipment market. Nowadays, there are more than 4500 such customers, and we constantly form new agreements. More than 750 contracts are concluded per day, because FAMAGA works all over the earth Germany, United Kingdom, Thailand, Suriname, Nepal, Rwanda, Fiji, Macedonia, Bulgaria, Latvia, Mongolia, China, Gambia, Romania, Norway, Tajikistan, Oman, Kiribati, Mozambique, Cape Verde, Panama, Georgia, Eritrea, North Korea, Slovakia, Bolivia, Hungary, Serbia, Dominica, Samoa, Philippines, Syria, Seychelles, Armenia, Sweden, Denmark, United Arab Emirates, New Zealand, Angola, Mexico, Afghanistan, Zimbabwe, United States, Jamaica. A well-developed logistics network and a partnership network assist us to deliver our goods anywhere in the earth as soon as possible without compromising product quality.
A special source of pride for FAMAGA is its workers, each of whom contributes to common cause. We accept into our team only professionals, who already have experience in the direction of manufacturing equipment.
All merchandises from FAMAGA are assured - we are responsible for the cause of our work. Nowadays, more than 10 million units of products have been provided, and this amount is increasing every day. We are glad that customers choose FAMAGA again and again, and we strive to make more progressive and technologically innovative industrial equipment so as to stay on the top.
To ask a question or book, contact us or write to the online chat on our site. You can also direct a list of the needful equipment to the email of corporation - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
CTP?L1 | Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle) |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
1 | IMP | Operating voltage of guard locking solenoid 24 V DC | WH | |
2 | UB | Operating voltage of AP electronics 24 V DC | BN | |
3 | FO1A | Safety output, channel 1 | GN | |
4 | FO1B | Safety output, channel 2 | YE | |
5 | OL | Guard locking monitoring output | GY | |
6 | OD | Door monitoring output | PK | |
7 | 0 V UB | Operating voltage of AP electronics 0 V | BU | |
8 | IMM | Operating voltage of guard locking solenoid 0 V | RD |
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,78 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP65/IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | max.1 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M12, 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Test-pulse interval | min.100 ms |
Test pulses | max.0,3 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 2 A |
External (solenoid operating voltage IMP) | 0,5 ... 8 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 6 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
HIGH U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OL | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Repeat accuracy R | 10 % |
Explosion protection | |
incl. cover | II3G Ex nA IIB T4 Gc X / II3D Ex tc IIIC T110°C Dc X |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |