We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are inspecting Euchner MGB-L1HB-EIA-L-136389 136389, communicate with FAMAGA, the world's key distributor of industrial equipment. Our company has progressed for more than ten years - these are ages of experience, which are represented in the quality of goods and special attention to each client. We value everyone, who worked with us - hence, our regular buyers accept the most convenient purchase conditions and discounts on the manufacturing equipment market. At present, there are more than 3500 such buyers, and we constantly compose new agreements. More than 600 contracts are concluded per day, because FAMAGA supplies all over the globe Germany, United Kingdom, Nepal, Central African Republic, New Zealand, Mozambique, Ecuador, China, Yemen, Montenegro, Albania, Armenia, Guyana, Saudi Arabia, Bolivia, Belgium, Grenada, Cape Verde, Libya, Nigeria, Tanzania, Cameroon, Chad, Qatar, Belarus, Macedonia, South Korea, Laos, Bangladesh, Mali, North Korea, Sudan, Paraguay, Luxembourg, Uganda, United Arab Emirates, Norway, Sweden, Antigua and Barbuda, Kazakhstan, Ghana, Bosnia and Herzegovina, Brazil, Malta. A well-elaborated logistics system and a partnership network assist us to conduct our elements anywhere in the globe quickly without undermining product quality.
A special source of good name for FAMAGA is its team members, each of whom contributes to our work. We invite into our team only professionals, who already have experience in the sphere of machine made streamlined equipment.
All spare parts from FAMAGA are assured - we are responsible for the result of our work. At the moment, more than 10 million units of products have been delivered, and this quantity is ascending every day. We are pleased that users choose FAMAGA again and again, and we are pleased to make more developed and technologically advanced industrial equipment so as keep on top of it.
To ask a question or order, call us by phone or write to the online chat on our site. You can also forward a list of the desirable equipment to the email of firm - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 3,1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP54 |
Resilience to vibration | In accordance with EN 60947-5-3 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN left |
Reaction time | |
Emergency stop / machine stop | max.100 ms Switch-off time |
Door position | max.250 ms Switch-off time |
Bolt position | max.250 ms Switch-off time |
Guard locking | max.250 ms Switch-off time |
Switching frequency | 0,25 Hz |
Connection | |
M12 Power, A-coded | |
M12 Power, A-coded | |
Ethernet/IP cable, Cat. 5e min. | M12 D-coded, screened |
M12 D-coded, screened | |
Guard locking principle | Closed-circuit current principle |
Locking force FZh | 2000 N |
Current consumption | max.500 mA |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0,5 kV |
Maximum feed-in current in the connection block | |
X1, X2 | max.4000 mA |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | |
Ethernet | Ethernet/IP cable, Cat. 5e min. |
Safety class | III |
Transponder coding | Unicode |
Power supply X1 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... 10% |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% |
Fusing | |
external | min.1 A Slow blow |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... 10% |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% |
Assured switch-off distance Sar | max.65 mm |
Data interface | |
Data protocol | |
Bus protocol | Ethernet/IP |
Safety protocol | CIP Safety |
Additional feature | Incl. cover set ID. No. 120344 |
Product version number | V1.2 |
Slide-in label | 4 pcs. without marking |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.37 x 10-9 |
Diagnostic Coverage (DC) | 99 |
Control of the guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.91 x 10-9 |
Emergency stop | |
B10D | |
Emergency stop | 0.1 x 106 |
Emergency-stop evaluation | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.05 x 10-9 |
Safety Integrity Level | SIL 3 (EN 62061:2005) |
Mission time | 20 |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,00 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP65 |
Installation orientation | Door hinge DIN left |
Additional feature | With mounting plate and automatic lockout mechanism |
Product version number | V3.0.0 |