We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CTP-L1-AP-U-HA-AZ-SA-EX-129512
Part number
129512
Stock availability:
On request
If you are looking for Euchner CTP-L1-AP-U-HA-AZ-SA-EX-129512 129512, contact FAMAGA, the world's top retailer of factory-made equipment. Our company has lasted for more than ten years - these are cycles of experience, which are expressed in the quality of products and personalseparate attention to each consumer. We appreciate everyone, who collaborated with us - therefore, our regular buyers bring in the most helpful purchase conditions and discounts on the manufacturing equipment market. At this moment, there are more than 4500 such customers, and we constantly compose new agreements. More than 650 agreements are achieved per day, because FAMAGA operates all over the earth Germany, United Kingdom, Suriname, Bangladesh, Central African Republic, Comoros, Burundi, Estonia, Kuwait, Senegal, Samoa, Iceland, Fiji, Liberia, Djibouti, Burma, Saudi Arabia, Luxembourg, Guinea, Austria, Mongolia, Kenya, North Korea, Gambia, Panama, South Korea, India, Mozambique, Lithuania, Equatorial Guinea, Argentina, Andorra, Algeria, Kazakhstan, Peru, Sudan, Switzerland, Ukraine, Syria, Cameroon, Montenegro, Bulgaria, Georgia, Slovakia, Tonga. A well-developed logistics bond and a partnership network allow us to send our goods anywhere in the earth quickly without undermining product quality.
A special source of honor for FAMAGA is its team members, each of whom contributes to common cause. We accept into our team only specialists, who already have experience in the field of machine made streamlined equipment.
All goods from FAMAGA are assured - we are responsible for the aftereffect of our work. At this moment, more than 10 million units of products have been shipped, and this quantity is ascending every day. We are glad that users choose FAMAGA again and again, and we are pleased to make more advanced and technologically advanced industrial equipment so as not to lower the bar.
To ask a question or make a request, get in touch with us or write to the online chat on our site. You can also send a list of the needful equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.
CTP?L1 | Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle) |
Plug connector (view of connection side) | PIN | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
1 | IMP | Operating voltage of guard locking solenoid 24 V DC | WH | |
2 | UB | Operating voltage of AP electronics 24 V DC | BN | |
3 | FO1A | Safety output, channel 1 | GN | |
4 | FO1B | Safety output, channel 2 | YE | |
5 | OI | Diagnostic output | GY | |
6 | OD | Door monitoring output | PK | |
7 | 0 V UB | Operating voltage of AP electronics 0 V | BU | |
8 | IMM | Operating voltage of guard locking solenoid 0 V | RD |
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,78 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP65/IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | max.1 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M12, 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Test-pulse interval | min.100 ms |
Test pulses | max.0,3 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 2 A |
External (solenoid operating voltage IMP) | 0,5 ... 8 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 6 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OI | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Repeat accuracy R | 10 % |
Explosion protection | |
incl. cover | II3G Ex nA IIB T4 Gc X / II3D Ex tc IIIC T110°C Dc X |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |