We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CTP-L1-AP-U-HA-AE-SII-129478
Part number
129478
Stock availability:
On request
If you are inspecting Euchner CTP-L1-AP-U-HA-AE-SII-129478 129478, connect FAMAGA, the world's chief producer of industrial equipment. Our company has existed for more than ten years - these are years of experience, which are depicted in the quality of outputs and private attention to each client. We praise everyone, who engaged with us - therefore, our regular customers obtain the most beneficial purchase terms and discounts on the factory-made equipment market. Today, there are more than 4500 such consumers, and we constantly make new agreements. More than 700 purchases are terminated per day, because FAMAGA operates all over the earth Germany, United Kingdom, Uruguay, East Timor, Dominica, Paraguay, Angola, Nigeria, Iran, Yemen, Greece, Serbia, Azerbaijan, Monaco, Kiribati, Canada, Netherlands, Iceland, Oman, Afghanistan, Peru, Bolivia, Malaysia, The Bahamas, Eswatini, Rwanda, Cape Verde, Czech Republic, Samoa, Costa Rica, United States, Cyprus, Haiti, Latvia, Laos, Mauritius, Kenya, Togo, Bangladesh, Philippines, Indonesia, Brunei, Tunisia, Mauritania, Qatar. A well-built logistics system and a partnership network guide us to conduct our items anywhere in the earth as soon as possible without disreputing product quality.
A specific source of good name for FAMAGA is its staff members, each of whom contributes to common cause. We request into our team only experts, who already have experience in the range of manufacturing equipment.
All outcomes from FAMAGA are guaranteed - we are responsible for the outcome of our work. Now, more than 10 million units of products have been supplied, and this amount is rising every day. We are glad that customers choose FAMAGA again and again, and we are happy to make more exceptional and technologically innovative industrial equipment so as not to lower the bar.
To consult or place an order, phone us or send a message to the online chat on our site. You can also send a list of the needful equipment to the email of our company - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
CTP?L1 | Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle) |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
X 1.1 | UB | Operating voltage of AP electronics 24 V DC | BN | |
X 1.2 | FO1A | Safety output, channel 1 | WH | |
X 1.3 | 0 V UB | Operating voltage of AP electronics 0 V | BU | |
X 1.4 | FO1B | Safety output, channel 2 | BK | |
X 1.5 | - | Not used | GY | |
X 2.1 | - | Not used | BN | |
X 2.2 | OD | Door monitoring output | WH | |
X 2.3 | IMM | Control input of guard locking solenoid, 0 V | BU | |
X 2.4 | IMP | Guard locking solenoid control input 24 V DC | BK | |
X 2.5 | - | Not used | GY |
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,42 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP67 / IP69 / IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | max.1 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5-pin + pin 5 not used |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Test-pulse interval | min.100 ms |
Test pulses | max.0,3 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 2 A |
External (solenoid operating voltage IMP) | 0,5 ... 8 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 6 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Repeat accuracy R | 10 % |
Additional feature | Escape release actuated by pushing |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |