We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CTP-L1-AP-U-HA-AZ-SII-129477
Part number
129477
Stock availability:
On request
If you are pursuing Euchner CTP-L1-AP-U-HA-AZ-SII-129477 129477, call FAMAGA, the world's main supplier of industrialized equipment. Our company has advanced for more than ten years - these are ages of experience, which are symbolized in the quality of items and personalseparate attention to each customer. We understand everyone, who conspired with us - so, our regular purchasers receive the most acceptable purchase forms and discounts on the manufacturing equipment market. Now, there are more than 4 thousand such customers, and we constantly form new agreements. More than 650 contracts are concluded per day, because FAMAGA works all over the planet Germany, United Kingdom, Sweden, Sudan, Uganda, Mexico, Jordan, Luxembourg, Nepal, Turkey, Pakistan, Mongolia, South Sudan, Gambia, China, Guinea, Chad, Serbia, Bhutan, Kazakhstan, Laos, Ukraine, Tonga, Uzbekistan, United Arab Emirates, Poland, Armenia, Seychelles, Greece, Algeria, Moldova, Denmark, Iraq, Ghana, Albania, Equatorial Guinea, Bolivia, Macedonia, East Timor, Malta, Bulgaria, Senegal, Jamaica, Chile, Andorra. A well-developed logistics link and a partnership network let us to dispatch our products anywhere in the planet on-time without compromising product quality.
A particular source of dignity for FAMAGA is its personnel, each of whom contributes to common cause. We accept into our team only professionals, who already have experience in the field of machine made streamlined equipment.
All spare parts from FAMAGA are affirmed - we are responsible for the cause of our work. At this moment, more than 10 million units of products have been shipped, and this quantity is amounting every day. We are happy that consumers choose FAMAGA again and again, and we strive to make more advanced and technologically advanced industrial equipment so as to stay on the top.
To request or book, get in touch with us or write a message to the online chat on our site. You can also direct a list of the necessary equipment to the email of corporation - we will contact you ourselves with a made commercial proposal from FAMAGA.
CTP?L1 | Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle) |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
X 1.1 | UB | Operating voltage of AP electronics 24 V DC | BN | |
X 1.2 | FO1A | Safety output, channel 1 | WH | |
X 1.3 | 0 V UB | Operating voltage of AP electronics 0 V | BU | |
X 1.4 | FO1B | Safety output, channel 2 | BK | |
X 1.5 | - | Not used | GY | |
X 2.1 | - | Not used | BN | |
X 2.2 | OD | Door monitoring output | WH | |
X 2.3 | IMM | Control input of guard locking solenoid, 0 V | BU | |
X 2.4 | IMP | Guard locking solenoid control input 24 V DC | BK | |
X 2.5 | - | Not used | GY |
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,42 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP67 / IP69 / IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | max.1 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5-pin + pin 5 not used |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Test-pulse interval | min.100 ms |
Test pulses | max.0,3 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 2 A |
External (solenoid operating voltage IMP) | 0,5 ... 8 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 6 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |