Name
CES-I-AR-U-C04-USA-119473
Part number
119473
Description
Transponder-Sicherheitsschalter mit Sicherheitsschloss CES-I-AR-U-C04-USA-119473
Stock availability:
On request
If you are questing Euchner CES-I-AR-U-C04-USA-119473 119473, catch up with FAMAGA, the world's dominant company of streamlined equipment. Our company has functioned for more than ten years - these are years of experience, which are outlined in the quality of items and particular attention to each user. We admire everyone, who joined with us - so, our regular buyers pick up the most acceptable purchase conditions and discounts on the manufacturing equipment market. Nowadays, there are more than 4 thousand such purchasers, and we constantly arrange new agreements. More than 750 purchases are terminated per day, because FAMAGA works all over the planet Germany, United Kingdom, Vietnam, Congo, Bolivia, Greece, Norway, Iraq, Liberia, Myanmar, Jamaica, Laos, Mongolia, East Timor, Turkmenistan, Montenegro, Poland, Bulgaria, Tanzania, Philippines, Chad, Uruguay, Brazil, Liechtenstein, Nigeria, Zambia, Malta, Mauritania, South Sudan, Ecuador, Argentina, Macedonia, Finland, Iran, Serbia, Suriname, Rwanda, Kiribati, Andorra, Eswatini, New Zealand, Afghanistan, Ghana, Jordan, Niger, Malaysia. A well-shaped logistics series and a partnership network assist us to deliver our goods anywhere in the planet as soon as possible without damaging product quality.
A special source of pride for FAMAGA is its team members, each of whom contributes to common cause. We call into our team only experts, who already have experience in the direction of machine made streamlined equipment.
All merchandises from FAMAGA are assured - we are responsible for the cause of our work. At this moment, more than 10 million units of products have been provided, and this quantity is ascending every day. We are happy that customers choose FAMAGA again and again, and we are glad to make more progressive and technologically advanced industrial equipment so as to stay on the top.
To ask a question or book, get in touch with us or write to the online chat on our site. You can also direct a list of the necessary equipment to the email of corporation - we will contact you ourselves with a made commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | FI1B | Enable input for channel 2 | WH | |
2 | UB | Power supply, DC 24 V | BN | |
3 | FO1A | Safety output, channel 1 | GN | |
4 | FO1B | Safety output, channel 2 | YE | |
5 | OD | Monitoring output | GY | |
6 | FI1A | Enable input for channel 1 | PK | |
7 | 0V | Ground, DC 0 V | BU | |
8 | RST | Reset input | RD |
Material | |
Rubber support | NBR 80 ±5 Shore |
Housing material | Plastic, PBT |
Weight | |
Net | 0,08 kg |
Ambient temperature | |
Cable static | -25 ... 65 °C |
Cable dynamic | -25 ... 65 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.140 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.0,8 Nm |
Ready delay | 10 s |
Switching frequency | max.1 Hz |
Connection | Connection cable PUR, length 1m with plug connector M12 8-pin |
Bending radius | |
static | 5 x cable diameter |
Dynamic | 10 x cable diameter |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV |
Current consumption | max.35 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Monitoring output OD | |
Type of output | Semiconductor output, p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs FO1A / FO1B | |
Test pulses | max.1,0 ms |
Test-pulse interval | min.140 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 200 mA |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1,5V ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
Additional feature | Rubber support included |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-9 |
Mission time | 20 |
Switch-on distance | |
Approach direction C or D (broad side) | 15 mm |
Approach direction A or B (front side) | 19 mm |
Assured operating distance Sao | |
Approach direction C or D (broad side) | min.10 mm |
Approach direction A or B (front side) | min.14 mm |
Switch-on distance | |
Approach direction C or D (broad side) | 11 mm |
Approach direction A or B (front side) | 15 mm |
Assured operating distance Sao | |
Approach direction A or B (front side) | 10 |
Approach direction C or D (broad side) | 6 |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Switching hysteresis | min.1 mm |