We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CES-I-AR-U-C04-SG-119469
Part number
119469
Description
Non-contact safety switch
Stock availability:
On request
If you are pursuing Euchner CES-I-AR-U-C04-SG-119469 119469, reach FAMAGA, the world's leading retailer of machine made equipment. Our company has lasted for more than ten years - these are ages of experience, which are portrayed in the quality of products and personalseparate attention to each purchaser. We admire everyone, who worked with us - hence, our regular consumers bring in the most acceptable purchase terms and discounts on the manufacturing equipment market. At present, there are more than 4000 such customers, and we constantly form new agreements. More than 750 contracts are concluded per day, because FAMAGA supplies all over the world Germany, United Kingdom, Bolivia, Myanmar, Djibouti, Namibia, Ukraine, Bosnia and Herzegovina, Uzbekistan, Belgium, Croatia, Lithuania, Zambia, Costa Rica, Azerbaijan, Senegal, Seychelles, Turkey, Kenya, Malaysia, Gambia, Uganda, Slovakia, Ecuador, Mongolia, Greece, Tonga, Burkina Faso, El Salvador, Burundi, Brazil, India, Pakistan, New Zealand, Albania, Dominica, Czech Republic, Armenia, Eswatini, Norway, Central African Republic, Madagascar, Bulgaria, Tunisia, Chile, Cyprus. A well-developed logistics connection and a partnership network help us to dispatch our elements anywhere in the world on-time without compromising product quality.
A specific source of dignity for FAMAGA is its employees, each of whom contributes to our work. We accept into our team only professionals, who already have experience in the direction of machine made streamlined equipment.
All spare parts from FAMAGA are verified - we are responsible for the cause of our work. At this moment, more than 10 million units of products have been provided, and this quantity is growing every day. We are proud that consumers choose FAMAGA again and again, and we strive to make more progressive and technologically advanced industrial equipment so as keep on top of it.
To get some advice or book, get in touch with us or send a message to the online chat on our site. You can also forward a list of the required equipment to the email of corporation - we will contact you ourselves with a made commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | FI1B | Enable input for channel 2 | WH | |
2 | UB | Power supply, DC 24 V | BN | |
3 | FO1A | Safety output, channel 1 | GN | |
4 | FO1B | Safety output, channel 2 | YE | |
5 | OD | Monitoring output | GY | |
6 | FI1A | Enable input for channel 1 | PK | |
7 | 0V | Ground, DC 0 V | BU | |
8 | RST | Reset input | RD |
Material | |
Rubber support | NBR 80 ±5 Shore |
Housing material | Plastic, PBT |
Weight | |
Net | 0,04 kg |
Ambient temperature | -25 ... 65 °C |
Degree of protection | IP67 / IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.140 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.0,8 Nm |
Ready delay | 10 s |
Switching frequency | max.1 Hz |
Connection | M8 plug connector, 8-pin |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV |
Current consumption | max.35 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Monitoring output OD | |
Type of output | Semiconductor output, p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs FO1A / FO1B | |
Test pulses | max.1,0 ms |
Test-pulse interval | min.140 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 200 mA |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1,5V ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
Additional feature | Rubber support included |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-9 |
Mission time | 20 |
Switch-on distance | |
Approach direction C or D (broad side) | 15 mm |
Approach direction A or B (front side) | 19 mm |
Assured operating distance Sao | |
Approach direction C or D (broad side) | min.10 mm |
Approach direction A or B (front side) | min.14 mm |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | |
Approach direction C or D (broad side) | 11 mm |
Approach direction A or B (front side) | 15 mm |
Assured operating distance Sao | |
Approach direction A or B (front side) | 10 |
Approach direction C or D (broad side) | 6 |