CES-I-AP-M-C04-U05-117328 Euchner 117328
 CES-I-AP-M-C04-U05-117328 Euchner 117328

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

CES-I-AP-M-C04-U05-117328 117328 Euchner

Manufacturer

Euchner

Country

Germany

Name

CES-I-AP-M-C04-U05-117328

Part number

117328

Description

Berührungsloser Sicherheitsschalter CES-I-AP-M-C04-U05-117328

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications CES-I-AP-M-C04-U05-117328 117328

If you are seeking Euchner CES-I-AP-M-C04-U05-117328 117328, connect FAMAGA, the world's influential distributor of manufacturing equipment. Our company has lasted for more than ten years - these are cycles of experience, which are depicted in the quality of goods and personalseparate attention to each buyer. We esteem everyone, who worked with us - therefore, our regular clients accept the most acceptable purchase forms and discounts on the factory-made equipment market. At this moment, there are more than 3500 such customers, and we constantly compose new agreements. More than 600 agreements are achieved per day, because FAMAGA operates all over the globe . A well-developed logistics chains and a partnership network cheer us to ship our goods anywhere in the globe with no delay without undermining product quality.

A particular source of repute for FAMAGA is its employees, each of whom contributes to our work. We accept into our team only experts, who already have experience in the sphere of manufacturing equipment.

All goods from FAMAGA are ensured - we are responsible for the aftereffect of our work. At this moment, more than 10 million units of products have been delivered, and this amount is growing every day. We are pleased that buyers choose FAMAGA again and again, and we are pleased to make more developed and technologically innovative industrial equipment so as not to lower the bar.

To inquire or make a request, get in touch with us or write a message to the online chat on our site. You can also send a list of the desirable equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.

Features CES-I-AP-M-C04-U05-117328 117328

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Connection cable PUR, 5 m, flying lead
  • Multicode
  • Monitoring output OD
Multicode evaluation Every suitable actuator is detected by the switch. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostics LED
Terminal assignment
Designation Function Conductor coloring of connection cable
UB Power supply, DC 24 V BN
FO1A Safety output, channel 1 WH
0V Ground, DC 0 V BU
FO1B Safety output, channel 2 BK
OD Monitoring output GY
Material
Rubber support NBR 80 ±5 Shore
Housing material Plastic, PBT
Weight
Net 0,2 kg
Ambient temperature
Cable static -25 ... 65 °C
Cable dynamic -25 ... 65 °C
Degree of protection IP67
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting method Surface mounting on metal
Mounting distance
Between 2 switches or 2 actuators min.140 mm
Installation orientation Any
Tightening torque
Fixing screws max.0,8 Nm
Ready delay 0,5 s
Switching frequency max.1 Hz
Connection connection cable PUR, length 5m
Bending radius
static 5 x cable diameter
Dynamic 10 x cable diameter
Electrical connection ratings
Operating voltage DC
UB 24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV
Current consumption
No load on outputs max.35 mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.300 ms
Safety class III
Risk time according to EN 60947-5-3 max.260 ms
Monitoring output OD
Type of output p-switching, short circuit-proof
Switching current max.50 mA
Output voltage 0,8 x UB ... UB V DC
Safety outputs FO1A / FO1B
Test pulses max.0,3 ms
Test-pulse interval min.100 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 150 mA
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1,5V ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Rated conditional short-circuit current 100 A
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Work area
Repeat accuracy R ? 10
Other
Additional feature Rubber support included
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 4.1 x 10-9
Mission time 20
In combination with Actuator CES-A-BDN-06-104730, CES-A-BBN-C04-115271Operating distance
Assured switch-off distance Sar
In y direction max.60 mm
In x/z direction max.40 mm
Switching hysteresis min.1 mm
In combination with Actuator CES-A-BDN-06-104730Operating distance
Switch-on distance
Approach direction A or B (front side) 19 mm
Approach direction C or D (broad side) 15 mm
Assured operating distance Sao
Approach direction A or B (front side) min.14 mm
Approach direction C or D (broad side) min.10 mm
In combination with Actuator CES-A-BBN-C04-115271Operating distance
Switch-on distance
Approach direction C or D (broad side) 11 mm
Approach direction A or B (front side) 15 mm
Assured operating distance Sao
Approach direction A or B (front side) min.10 mm
Approach direction C or D (broad side) min.6 mm