Manufacturer
Euchner
Country
Germany
Name
CET3-AR-CDA-CH-50X-SG-114090
Part number
114090
Stock availability:
On request
If you are questing Euchner CET3-AR-CDA-CH-50X-SG-114090 114090, reach FAMAGA, the world's key company of mechanized equipment. Our company has existed for more than ten years - these are ages of experience, which are portrayed in the quality of outputs and particular attention to each consumer. We admire everyone, who engaged with us - hence, our regular purchasers pick up the most acceptable purchase conditions and discounts on the machine made streamlined equipment market. Now, there are more than 4500 such purchasers, and we constantly arrange new agreements. More than 750 contracts are concluded per day, because FAMAGA supplies all over the globe Germany, United Kingdom, Papua New Guinea, Guinea, Côte d\'Ivoire, Moldova, Cambodia, Grenada, Guinea-Bissau, Zambia, Kazakhstan, Niger, Romania, Dominica, Malawi, Greece, Bulgaria, Macedonia, Andorra, Armenia, Bosnia and Herzegovina, Syria, Austria, United States, Tonga, Senegal, Bangladesh, Norway, Tanzania, Swaziland, Thailand, Panama, Azerbaijan, North Korea, Cameroon, Rwanda, The Gambia, Kyrgyzstan, Algeria, Sierra Leone, Seychelles, Brazil, Slovakia, New Zealand, Mongolia, Mauritius. A well-developed logistics network and a partnership network assist us to ship our products anywhere in the earth quickly without damaging product quality.
A specific source of pride for FAMAGA is its personnel, each of whom contributes to our work. We accept into our team only specialists, who already have experience in the direction of factory-made equipment.
All outcomes from FAMAGA are guaranteed - we are responsible for the aftereffect of our work. Nowadays, more than 10 million units of products have been provided, and this quantity is amounting every day. We are pleased that buyers choose FAMAGA again and again, and we strive to make more progressive and technologically modern industrial equipment so as keep on top of it.
To consult or make a request, contact us or send a message to the online chat on our site. You can also forward a list of the desirable equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.
CET3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | freely configurable |
LED 2 gn | illuminates when door is closed |
OUT | Monitoring output (semiconductor) |
OUT D | Door monitoring output |
RST | Reset input |
Housing material | |
Slide | Stainless steel |
Safety switch housing | Die-cast aluminum |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
Z | ±4 mm |
Y | ±5 mm |
X | ±5 mm |
Ready delay | 10 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5 and 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Operating voltage DC | |
LED | 24 V DC -15% ... 10% |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IB | 80 mA |
ICM | 480 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 8 A |
External (solenoid operating voltage UCM) | 0,5 ... 8 A |
Power consumption | |
Solenoid | max.12 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 30V DC, 2A |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs OA/OB | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output OA / OB | 1 ... 200 mA |
Output voltage | |
High U(OA) / U(OB) | UB-1,5V ... UB V DC |
Low U(OA) / U(OB) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.400 ms |
Switch-on time | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT | 1 ... 50 mA |
Output voltage | |
OUT | 0,8xUB ... UB V DC |
Switching delay from state change | max.400 ms |
Monitoring output OUT D | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT D | 1 ... 50 mA |
Output voltage | |
OUT D | 0,8xUB ... UB V DC |
Switching delay from state change | max.700 ms |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Monitoring of guard locking and the safety guard position | |
Category | |
Head upward | 3 |
Head downward or horizontal | 4 |
Performance Level | PL e |
PFHD | |
Head upward | 4.29 x 10-8 |
Head downward or horizontal | 3.1 x 10-9 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Mission time | 20 y |