We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CET4-AR-CRA-CH-50X-SG-C2355-113609
Part number
113609
Stock availability:
On request
If you are pursuing Euchner CET4-AR-CRA-CH-50X-SG-C2355-113609 113609, reach FAMAGA, the world's major producer of industrial equipment. Our company has existed for more than ten years - these are years of experience, which are expressed in the quality of outcomes and private attention to each client. We admire everyone, who liased with us - so, our regular consumers receive the most acceptable purchase conditions and discounts on the factory-made equipment market. Now, there are more than 4500 such customers, and we constantly make new agreements. More than 600 contracts are concluded per day, because FAMAGA supplies all over the earth Germany, United Kingdom, Côte d\'Ivoire, The Bahamas, Ecuador, Burma, Austria, Burundi, Singapore, Israel, Uganda, Ghana, Angola, Palestine, Bahamas, Kyrgyzstan, Equatorial Guinea, Namibia, Iceland, Canada, Brazil, Chad, Grenada, Central African Republic, Mexico, Nigeria, Algeria, Liechtenstein, Lithuania, Zambia, Zimbabwe, Sierra Leone, Peru, Armenia, Kiribati, Azerbaijan, Thailand, Bolivia, Iran, Malaysia, Morocco, Jordan, Kazakhstan, Montenegro, Georgia, Chile, Denmark. A well-built logistics bond and a partnership network help us to dispatch our elements anywhere in the world quickly without disreputing product quality.
A specific source of pride for FAMAGA is its team members, each of whom contributes to common cause. We request into our team only specialists, who already have experience in the direction of industrial equipment.
All goods from FAMAGA are verified - we are responsible for the aftereffect of our work. At this moment, more than 10 million units of products have been shipped, and this amount is ascending every day. We are glad that users choose FAMAGA again and again, and we are happy to make more developed and technologically advanced industrial equipment so as keep on top of it.
To consult or place an order, phone us or send a message to the online chat on our site. You can also forward a list of the required equipment to the email of firm - we will contact you ourselves with a made commercial proposal from FAMAGA.
CET4 | Open-circuit current principle guard locking by solenoid force. Activation of the guard locking by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | illuminates when the solenoid is energized |
LED 2 gn | illuminates when door is closed |
OUT | Monitoring output (semiconductor) |
OUT D | Door monitoring output |
RST | Reset input |
Housing material | |
Safety switch housing | Die-cast aluminum |
Slide | Stainless steel |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
X | ±5 mm |
Z | ±4 mm |
Y | ±5 mm |
Ready delay | 10 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5 and 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Open-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Operating voltage DC | |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
LED | 24 V DC -15% ... 10% |
Current consumption | |
IB | 80 mA |
ICM | 480 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 8 A |
External (solenoid operating voltage UCM) | 0,5 ... 8 A |
Power consumption | |
Solenoid | max.14 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 30V DC, 2A |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs OA/OB | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output OA / OB | 1 ... 200 mA |
Output voltage | |
High U(OA) / U(OB) | UB-1,5V ... UB V DC |
Low U(OA) / U(OB) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Single device | max.400 ms |
Delay per device | 5 ms |
Switch-on time | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT | 1 ... 50 mA |
Output voltage | |
OUT | 0,8xUB ... UB V DC |
Switching delay from state change | max.400 ms |
Monitoring output OUT D | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT D | 1 ... 50 mA |
Output voltage | |
OUT D | 0,8xUB ... UB V DC |
Switching delay from state change | max.700 ms |
Repeat accuracy R | 10 % |
C number | |
C2355 | PIN assignment on plug connector to customer requirements |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Monitoring of guard locking and the safety guard position | |
Category | |
Head upward | 3 |
Head downward or horizontal | 4 |
Performance Level | PL e |
PFHD | |
Head upward | 4.29 x 10-8 |
Head downward or horizontal | 3.1 x 10-9 |
Mission time | 20 y |