We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CET3-AR-CRA-AH-50F-SH-113148
Part number
113148
Stock availability:
On request
If you are pursuing Euchner CET3-AR-CRA-AH-50F-SH-113148 113148, connect FAMAGA, the world's the best retailer of industrial equipment. Our company has advanced for more than ten years - these are ages of experience, which are depicted in the quality of products and private attention to each client. We esteem everyone, who liased with us - therefore, our regular customers bring in the most helpful purchase terms and discounts on the factory-made equipment market. At this time, there are more than 4000 such consumers, and we constantly compose new agreements. More than 600 contracts are concluded per day, because FAMAGA operates all over the world Germany, United Kingdom, Bahamas, Jordan, Croatia, Kuwait, Qatar, Turkmenistan, Latvia, Cambodia, Morocco, Andorra, Eritrea, Grenada, Canada, Indonesia, Burma, Burkina Faso, Benin, Mozambique, Nicaragua, Monaco, Tajikistan, Thailand, Botswana, Gambia, Jamaica, Egypt, Guatemala, South Sudan, Russia, Moldova, Pakistan, Finland, Philippines, East Timor, Mongolia, Mauritius, Ukraine, Algeria, Cyprus, Nepal, Suriname, Eswatini, Mexico, China. A well-built logistics system and a partnership network help us to dispatch our units anywhere in the world with no delay without undermining product quality.
A specific source of dignity for FAMAGA is its workers, each of whom contributes to our work. We request into our team only professionals, who already have experience in the sphere of manufacturing equipment.
All merchandises from FAMAGA are guaranteed - we are responsible for the result of our work. At this moment, more than 10 million units of products have been delivered, and this amount is increasing every day. We are proud that buyers choose FAMAGA again and again, and we are pleased to make more developed and technologically innovative industrial equipment so as not to lower the bar.
To consult or order, get in touch with us or send a message to the online chat on our site. You can also send a list of the required equipment to the email of firm - we will contact you ourselves with a made commercial proposal from FAMAGA.
CET3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | freely configurable |
LED 2 gn | freely configurable |
OUT | Monitoring output (semiconductor) |
OUT D | Door monitoring output |
RST | Reset input |
J | Teach-in input |
Housing material | |
Safety switch housing | Die-cast aluminum |
Slide | Stainless steel |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65/IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
Z | ±4 mm |
Y | ±5 mm |
X | ±5 mm |
Ready delay | 10 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M23, 19-pin, RC18 |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N FZH = FMAX/1.3 |
Operating voltage DC | |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
LED | 24 V DC -15% ... 10% |
Current consumption | |
IB | 80 mA |
ICM | 480 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 8 A |
External (solenoid operating voltage UCM) | 0,5 ... 8 A |
Power consumption | |
Solenoid | max.12 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 30V DC, 2A |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs OA/OB | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output OA / OB | 1 ... 200 mA |
Output voltage | |
Low U(OA) / U(OB) | 0 ... 1 V DC |
High U(OA) / U(OB) | UB-1,5V ... UB V DC |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.400 ms |
Switch-on time | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT | 1 ... 50 mA |
Output voltage | |
OUT | 0,8xUB ... UB V DC |
Switching delay from state change | max.400 ms |
Monitoring output OUT D | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT D | 1 ... 50 mA |
Output voltage | |
OUT D | 0,8xUB ... UB V DC |
Switching delay from state change | max.700 ms |
Teach-in input | |
Input voltage | |
High | 15 ... 27,6 V DC |
Low | 0 ... 1 V DC |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Monitoring of guard locking and the safety guard position | |
Category | |
Head upward | 3 |
Head downward or horizontal | 4 |
Performance Level | PL e |
PFHD | |
Head upward | 4.29 x 10-8 |
Head downward or horizontal | 3.1 x 10-9 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Mission time | 20 y |