We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
MGB-L0-APA-AA1A2-S1-R-112596
Part number
112596
Stock availability:
On request
If you are questing Euchner MGB-L0-APA-AA1A2-S1-R-112596 112596, contact FAMAGA, the world's principle producer of mechanized equipment. Our company has advanced for more than ten years - these are ages of experience, which are expressed in the quality of outputs and individual attention to each orderer. We admire everyone, who liased with us - therefore, our regular purchasers obtain the most convenient purchase terms and discounts on the manufacturing equipment market. At this moment, there are more than 4500 such clients, and we constantly sign new agreements. More than 750 contracts are concluded per day, because FAMAGA operates all over the earth Germany, United Kingdom, Chad, Vietnam, Kiribati, Iraq, Armenia, Croatia, Central African Republic, Oman, Bosnia and Herzegovina, Estonia, Burundi, Russia, Liechtenstein, Bangladesh, Nicaragua, Bulgaria, Czech Republic, Thailand, Azerbaijan, Haiti, Kyrgyzstan, Jamaica, Ukraine, Kazakhstan, Austria, Andorra, Denmark, Comoros, Rwanda, Turkmenistan, Hungary, Macedonia, Angola, Egypt, Tunisia, Samoa, North Korea, Nigeria, Sierra Leone, Jordan, Serbia, New Zealand, Namibia. A advanced logistics network and a partnership network help us to deliver our goods anywhere in the earth immediately without discrediting product quality.
A specific source of pride for FAMAGA is its employees, each of whom contributes to common cause. We propose into our team only experts, who already have experience in the direction of machine made streamlined equipment.
All spare parts from FAMAGA are affirmed - we are responsible for the aftereffect of our work. At the moment, more than 10 million units of products have been provided, and this quantity is growing every day. We are glad that clients choose FAMAGA again and again, and we are eager to make more progressive and technologically advanced industrial equipment so as not to lower the bar.
To request or make a request, call us by phone or send a message to the online chat on our site. You can also send a list of the needful equipment to the email of organization - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
MGB-L0... | The bolt tongue in the handle module is moved into and out of the interlocking module by actuating the door handle. The door arm is not locked in the locked position. |
OD | ON when the door is closed |
OT | Bolt tongue inserted in the evaluation module |
OI | Diagnostics, there is a fault |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,35 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN right |
Switching frequency | 0,25 Hz |
Connection | Plug connector RC18 |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.10 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.0,3 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Additional feature | Mounting plate |
Product version number | V3.0.0 |
Monitoring of the position of the safety guard | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Mission time | 20 y |