We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
MGB-L2-ARA-AE5A1-S1-L-111925
Part number
111925
Stock availability:
On request
If you are seeking Euchner MGB-L2-ARA-AE5A1-S1-L-111925 111925, catch up with FAMAGA, the world's foremost company of industrialized equipment. Our company has advanced for more than ten years - these are ages of experience, which are outlined in the quality of spare parts and special attention to each customer. We value everyone, who liased with us - so, our regular clients pick up the most attractive purchase terms and discounts on the factory-made equipment market. Nowadays, there are more than 3500 such buyers, and we constantly arrange new agreements. More than 600 contracts are concluded per day, because FAMAGA works all over the globe Germany, United Kingdom, Laos, Botswana, United States, Kiribati, Italy, Azerbaijan, Oman, Moldova, United Arab Emirates, Malaysia, Burma, Papua New Guinea, North Korea, East Timor, Kuwait, Colombia, Haiti, Qatar, Nicaragua, Swaziland, Ukraine, Samoa, Sweden, Suriname, Estonia, Luxembourg, Australia, Yemen, Croatia, Indonesia, Pakistan, Tanzania, Fiji, Kazakhstan, Bolivia, Israel, China, Ireland, Denmark, Vietnam, Niger, The Gambia, Mozambique. A well-elaborated logistics link and a partnership network help us to ship our goods anywhere in the globe quickly without damaging product quality.
A specific source of repute for FAMAGA is its team members, each of whom contributes to our work. We invite into our team only specialists, who already have experience in the sphere of manufacturing equipment.
All goods from FAMAGA are ensured - we are responsible for the result of our work. Now, more than 10 million units of products have been delivered, and this amount is ascending every day. We are pleased that users choose FAMAGA again and again, and we are glad to make more developed and technologically innovative industrial equipment so as to stay on the top.
To inquire or order, phone us or send a message to the online chat on our site. You can also direct a list of the desirable equipment to the email of firm - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
MGB-L1... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle, electrically locked). |
OT | Bolt tongue inserted in the evaluation module |
OI | Diagnostics, there is a fault |
S1 | 2 positively driven NC contacts and 1 NO contact, emergency stop with turn-to-reset, not illuminated |
S2 | 1 NO contact, yellow, illuminated |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN left |
Switching frequency | 0,25 Hz |
Connection | Plug connector RC18 |
Guard locking principle | Open-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.1 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Controls and indicators | |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Machine stop | |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Belegungsschema | L1 |
Position 1 | |
Ausfuhrung | Machine stop |
Einlegeschild | |
Extras | |
Farbe | |
Schaltelement | 2 pos. driven NC |
Position 2 | |
Ausfuhrung | Cover for indicators |
Einlegeschild | |
Extras | |
Farbe | Green |
Schaltelement | |
Position 3 | |
Ausfuhrung | Cover for indicators |
Einlegeschild | |
Extras | |
Farbe | Red |
Schaltelement |
Product version number | V3.0.3 |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Mission time | 20 y |