We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CET4-AR-CRA-CH-50X-SH-110202
Part number
110202
Stock availability:
On request
If you are looking for Euchner CET4-AR-CRA-CH-50X-SH-110202 110202, connect FAMAGA, the world's the best supplier of industrial equipment. Our company has worked for more than ten years - these are cycles of experience, which are portrayed in the quality of outputs and private attention to each buyer. We admire everyone, who cooperated with us - therefore, our regular consumers receive the most acceptable purchase forms and discounts on the industrial equipment market. Now, there are more than 4500 such consumers, and we constantly make new agreements. More than 750 contracts are concluded per day, because FAMAGA operates all over the world Germany, United Kingdom, Grenada, Gambia, Honduras, Burma, Sweden, Kazakhstan, Burundi, Slovenia, Antigua and Barbuda, Bahamas, Uzbekistan, Mexico, Palestine, Slovakia, Pakistan, Libya, Liberia, China, El Salvador, Guyana, Malawi, New Zealand, Azerbaijan, Mongolia, Denmark, Mozambique, Philippines, Kyrgyzstan, Greece, Burkina Faso, Bosnia and Herzegovina, Macedonia, Jordan, Uruguay, Chile, Malta, Namibia, Brazil, Panama, Zambia, Tunisia, North Korea, Mali, Equatorial Guinea, Belarus. A well-elaborated logistics system and a partnership network let us to dispatch our products anywhere in the earth promptly without disreputing product quality.
A specific source of honor for FAMAGA is its team members, each of whom contributes to our work. We invite into our team only specialists, who already have experience in the field of industrial equipment.
All products from FAMAGA are assured - we are responsible for the outcome of our work. At the moment, more than 10 million units of products have been provided, and this quantity is ascending every day. We are proud that buyers choose FAMAGA again and again, and we are eager to make more advanced and technologically developed industrial equipment so as keep on top of it.
To ask a question or place an order, call us by phone or send a message to the online chat on our site. You can also send a list of the required equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.
CET4 | Open-circuit current principle guard locking by solenoid force. Activation of the guard locking by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | freely configurable |
LED 2 gn | freely configurable |
OUT | Monitoring output (semiconductor) |
OUT D | Door monitoring output |
RST | Reset input |
Housing material | |
Slide | Stainless steel |
Safety switch housing | Die-cast aluminum |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65/IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
Z | ±4 mm |
Y | ±5 mm |
X | ±5 mm |
Ready delay | 10 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M23, 19-pin, RC18 |
Approach speed | 20 m/min |
Guard locking principle | Open-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Operating voltage DC | |
LED | 24 V DC -15% ... 10% |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IB | 80 mA |
ICM | 480 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (solenoid operating voltage UCM) | 0,5 ... 8 A |
External (operating voltage UB) | 0,25 ... 8 A |
Power consumption | |
Solenoid | max.14 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 30V DC, 2A |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs OA/OB | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output OA / OB | 1 ... 200 mA |
Output voltage | |
Low U(OA) / U(OB) | 0 ... 1 V DC |
High U(OA) / U(OB) | UB-1,5V ... UB V DC |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Single device | max.400 ms |
Delay per device | 5 ms |
Switch-on time | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT | 1 ... 50 mA |
Output voltage | |
OUT | 0,8xUB ... UB V DC |
Switching delay from state change | max.400 ms |
Monitoring output OUT D | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT D | 1 ... 50 mA |
Output voltage | |
OUT D | 0,8xUB ... UB V DC |
Switching delay from state change | max.700 ms |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Monitoring of guard locking and the safety guard position | |
Category | |
Head upward | 3 |
Head downward or horizontal | 4 |
Performance Level | PL e |
PFHD | |
Head upward | 4.29 x 10-8 |
Head downward or horizontal | 3.1 x 10-9 |
Mission time | 20 y |