We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CET3-AR-CRA-AH-50X-SG-109401
Part number
109401
Type
Solenoid interlock
Description
Elektromagnetisches Schloss für die Anca MX-5-Maschine, Foto beigefügt
Stock availability:
On request
If you are questing Euchner CET3-AR-CRA-AH-50X-SG-109401 109401, reach FAMAGA, the world's influential provider of industrial equipment. Our company has existed for more than ten years - these are cycles of experience, which are portrayed in the quality of outputs and personalseparate attention to each purchaser. We admire everyone, who cooperated with us - hence, our regular purchasers get the most acceptable purchase forms and discounts on the machine made streamlined equipment market. Now, there are more than 4500 such customers, and we constantly arrange new agreements. More than 750 agreements are achieved per day, because FAMAGA supplies all over the globe Germany, United Kingdom, Antigua and Barbuda, Tonga, Russia, Belize, Myanmar, Sudan, Ukraine, Fiji, Kiribati, Guyana, Syria, Liechtenstein, Senegal, Comoros, Central African Republic, North Korea, Guatemala, Bolivia, Cyprus, Tunisia, Japan, Israel, Zambia, Suriname, Estonia, New Zealand, Libya, Kuwait, Andorra, Moldova, Macedonia, Jordan, Turkey, Nigeria, Austria, Montenegro, Finland, Kyrgyzstan, India, Iceland, Paraguay, Tanzania, Swaziland. A well-shaped logistics system and a partnership network cheer us to ship our products anywhere in the earth immediately without damaging product quality.
A specific source of pride for FAMAGA is its employees, each of whom contributes to our work. We call into our team only experts, who already have experience in the direction of factory-made equipment.
All items from FAMAGA are guaranteed - we are responsible for the aftereffect of our work. Nowadays, more than 10 million units of products have been provided, and this quantity is growing every day. We are pleased that buyers choose FAMAGA again and again, and we strive to make more progressive and technologically modern industrial equipment so as keep on top of it.
To consult or make a request, contact us or send a message to the online chat on our site. You can also forward a list of the desirable equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.
CET3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | freely configurable |
LED 2 gn | illuminates when door is closed |
OUT | Monitoring output (semiconductor) |
OUT D | Door monitoring output (semiconductor) |
RST | Reset input |
J | Teach-in input |
Housing material | |
Slide | Stainless steel |
Safety switch housing | Die-cast aluminum |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
Z | ±4 mm |
Y | ±5 mm |
X | ±5 mm |
Ready delay | 10 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5 and 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Operating voltage DC | |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
LED | 24 V DC -15% ... 10% |
Current consumption | |
ICM | 480 mA |
IB | 80 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 8 A |
External (solenoid operating voltage UCM) | 0,5 ... 8 A |
Power consumption | |
Solenoid | max.12 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 30V DC, 2A |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs OA/OB | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output OA / OB | 1 ... 200 mA |
Output voltage | |
High U(OA) / U(OB) | UB-1,5V ... UB V DC |
Low U(OA) / U(OB) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Single device | max.400 ms |
Delay per device | 5 ms |
Switch-on time | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT | 1 ... 50 mA |
Output voltage | |
OUT | 0,8xUB ... UB V DC |
Switching delay from state change | max.400 ms |
Monitoring output OUT D | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT D | 1 ... 50 mA |
Output voltage | |
OUT D | 0,8xUB ... UB V DC |
Switching delay from state change | max.700 ms |
Teach-in input | |
Input voltage | |
High | 15 ... 27,6 V DC |
Low | 0 ... 1 V DC |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Monitoring of guard locking and the safety guard position | |
Category | |
Head upward | 3 |
Head downward or horizontal | 4 |
Performance Level | PL e |
PFHD | |
Head upward | 4.29 x 10-8 |
Head downward or horizontal | 3.1 x 10-9 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Mission time | 20 y |