We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CET1-AR-CDA-CH-50X-SG-109231
Part number
109231
Stock availability:
On request
If you are seeking Euchner CET1-AR-CDA-CH-50X-SG-109231 109231, call FAMAGA, the world's central company of mechanized equipment. Our company has advanced for more than ten years - these are years of experience, which are portrayed in the quality of spare parts and special attention to each customer. We value everyone, who cooperated with us - thus, our regular buyers bring in the most attractive purchase forms and discounts on the machine made streamlined equipment market. Nowadays, there are more than 4 thousand such purchasers, and we constantly form new agreements. More than 700 agreements are achieved per day, because FAMAGA works all over the planet Germany, United Kingdom, Georgia, Qatar, Belize, El Salvador, Papua New Guinea, Mauritius, Togo, Azerbaijan, China, Turkmenistan, Bangladesh, Fiji, Yemen, Paraguay, Dominica, Malaysia, Niger, Ukraine, Denmark, Jamaica, Liberia, South Korea, Finland, Uruguay, Nigeria, Suriname, Comoros, Iran, Cyprus, Ireland, Djibouti, The Gambia, Swaziland, Luxembourg, Afghanistan, Indonesia, Lithuania, Mozambique, Cape Verde, Serbia, Mexico, Vietnam, Thailand. A well-developed logistics network and a partnership network cheer us to ship our elements anywhere in the earth on-time without discrediting product quality.
A special source of repute for FAMAGA is its employees, each of whom contributes to our work. We invite into our team only professionals, who already have experience in the sphere of machine made streamlined equipment.
All outcomes from FAMAGA are assured - we are responsible for the result of our work. Now, more than 10 million units of products have been provided, and this bulk is rising every day. We are happy that users choose FAMAGA again and again, and we strive to make more exceptional and technologically innovative industrial equipment so as to stay on the top.
To request or make a request, contact us or write a message to the online chat on our site. You can also direct a list of the needful equipment to the email of corporation - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
CET1 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | freely configurable |
LED 2 gn | freely configurable |
OUT | Monitoring output (semiconductor) |
RST | Reset input |
Housing material | |
Slide | Stainless steel |
Safety switch housing | Die-cast aluminum |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP67 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
X | ±5 mm |
Y | ±5 mm |
Z | ±4 mm |
Ready delay | 10 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5 and 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Operating voltage DC | |
LED1 , LED2 | 24 V DC -15% ... 10% |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IB | 80 mA |
ICM | 480 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 8 A |
External (operating voltage UCM) | 0,5 ... 8 A |
Power consumption | |
Solenoid | max.12 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs OA/OB | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
High U(OA,OB) | UB-1,5V ... UB V DC |
Low U(OA,OB) | 0 ... 1 V DC |
Output current | |
per safety output | 1 ... 200 mA |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Single device | max.400 ms |
Delay per device | 5 ms |
Switch-on time | |
Safety outputs | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Monitoring output OUT | |
Type of output | Semiconductor output, p-switching, short circuit-proof |
Output voltage | |
OUT | 0,8xUB ... UB V DC |
Output current | |
OUT | 1 ... 50 mA |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Monitoring of guard locking and the safety guard position | |
Category | |
Head upward | 3 |
Head downward or horizontal | 4 |
Performance Level | PL e |
PFHD | |
Head upward | 4.29 x 10-8 |
Head downward or horizontal | 3.1 x 10-9 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Mission time | 20 y |