CES-AP-CR2-CH-SB-109168 Euchner 109168
 CES-AP-CR2-CH-SB-109168 Euchner 109168

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

CES-AP-CR2-CH-SB-109168 109168 Euchner

Manufacturer

Euchner

Country

Germany

Name

CES-AP-CR2-CH-SB-109168

Part number

109168

Description

CES-AP-CR2-CH-SB

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications CES-AP-CR2-CH-SB-109168 109168

If you are inspecting Euchner CES-AP-CR2-CH-SB-109168 109168, connect FAMAGA, the world's foremost provider of factory-made equipment. Our company has worked for more than ten years - these are years of experience, which are illustrated in the quality of outcomes and private attention to each buyer. We understand everyone, who engaged with us - so, our regular consumers get the most convenient purchase terms and discounts on the factory-made equipment market. Now, there are more than 4 thousand such buyers, and we constantly compose new agreements. More than 600 contracts are concluded per day, because FAMAGA works all over the world . A advanced logistics chains and a partnership network help us to conduct our goods anywhere in the globe immediately without disreputing product quality.

A particular source of honor for FAMAGA is its workers, each of whom contributes to common cause. We request into our team only experts, who already have experience in the field of factory-made equipment.

All items from FAMAGA are verified - we are responsible for the result of our work. At the moment, more than 10 million units of products have been supplied, and this amount is ascending every day. We are happy that customers choose FAMAGA again and again, and we are pleased to make more developed and technologically innovative industrial equipment so as to stay on the top.

To ask a question or book, phone us or send a message to the online chat on our site. You can also send a list of the desirable equipment to the email of firm - we will contact you ourselves with a worked out commercial proposal from FAMAGA.

Features CES-AP-CR2-CH-SB-109168 109168

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Door hinge right
  • Category 4/PL e according to EN ISO 13849-1
  • Connection cable PUR, 0.2 m, plug connector M12, 5-core, pin 5 not used
  • Multicode
  • Two safety screws M4x14 included
Short circuit monitoring The switch generates its own clock signal on the output cables OA/OB. Pay attention to this aspect when connecting to control systems and relays. Multicode evaluation Every suitable actuator is detected by the switch. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostics LED
Approach directions Typical operating distance (Actuator CES-A-BLN... in conjunction with safety switch CES-AP-C.2-... in case of mounting on plastic) For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the operating distance of the side lobes is not entered. Attention: The operating distance may vary depending on the background material and installation situation. Connector assignment
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connection cable
1 UB Power supply, DC 24 V BN
2 OA Safety output, channel 1 WH
3 0V Ground, DC 0 V BU
4 OB Safety output, channel 2 BK
5 - n.c. GY
Housing material Plastic, PBT
Weight
Net 0,06 kg
Ambient temperature
Cable static -25 ... 65 °C
Cable dynamic -5 ... 65 °C
Degree of protection IP67
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting method Surface mounting on metal
Mounting distance
Between 2 switches or 2 actuators min.400 mm
Installation orientation Any
Tightening torque
Fixing screws max.1 Nm
Ready delay 0,5 s
Switching frequency max.1 Hz
Connection Connection cable PUR 0.2m with plug connector M12 5-pin, pin 5 not used
Bending radius
static 5 x cable diameter
Dynamic 10 x cable diameter
Electrical connection ratings
Operating voltage DC
UB 24 V DC 15% ... 15% Regulated, residual ripple < 5 %
Current consumption max.30 mA
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.300 ms
Safety class III
Risk time according to EN 60947-5-3 max.260 ms
Safety outputs OA/OB
Test pulses max.0,3 ms
Test-pulse interval min.100 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 150 mA
Output voltage
LOW U(OA) / U(OB) 0 ... 1 V DC
HIGH U(OA) / U(OB) UB-1,5V ... UB V DC
Rated conditional short-circuit current 100 A
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Work area
Repeat accuracy R ? 10
Other
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 1.8 x 10-9
Mission time 20
In combination with Actuator CES-A-BLN-R2-100776, CES-A-BLN-U2-103450, CES-A-BLN-L2-104510, CES-A-BLN-U2-112710Operating distance
Switch-on distance 15 mm
Assured switch-off distance Sar
In y direction max.60 mm
In x/z direction max.40 mm
Assured operating distance Sao min.10 mm
Switching hysteresis min.1 mm
In combination with Actuator CES-A-BDN-06-104730Operating distance
Switch-on distance 19 mm
Assured switch-off distance Sar
In y direction max.60 mm
In x/z direction max.40 mm
Assured operating distance Sao min.14 mm
Switching hysteresis min.1 mm