We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CES-AP-CL2-AH-SB-106553
Part number
106553
Description
SENSOR FECHTEN
Stock availability:
On request
If you are questing Euchner CES-AP-CL2-AH-SB-106553 106553, reach FAMAGA, the world's dominant producer of machine made equipment. Our company has advanced for more than ten years - these are years of experience, which are outlined in the quality of outcomes and personalseparate attention to each customer. We admire everyone, who worked with us - so, our regular customers bring in the most acceptable purchase forms and discounts on the factory-made equipment market. At this moment, there are more than 4 thousand such consumers, and we constantly compose new agreements. More than 600 transactions are made per day, because FAMAGA works all over the earth Germany, United Kingdom, Togo, Luxembourg, Guinea-Bissau, Tanzania, Vietnam, Botswana, Denmark, United States, Tonga, Colombia, Cyprus, Haiti, Uruguay, Singapore, Estonia, Oman, Ghana, Mali, Mongolia, Djibouti, Cameroon, Swaziland, South Korea, The Bahamas, Niger, Turkmenistan, Suriname, Bosnia and Herzegovina, Serbia, Afghanistan, Benin, Bolivia, Zimbabwe, Egypt, Dominica, Mauritius, Rwanda, Nepal, Ireland, Mauritania, Sweden, Finland, Sierra Leone. A advanced logistics bond and a partnership network allow us to deliver our elements anywhere in the planet immediately without compromising product quality.
A specific source of dignity for FAMAGA is its workers, each of whom contributes to common cause. We accept into our team only specialists, who already have experience in the direction of manufacturing equipment.
All goods from FAMAGA are guaranteed - we are responsible for the result of our work. At this moment, more than 10 million units of products have been delivered, and this amount is growing every day. We are happy that users choose FAMAGA again and again, and we are pleased to make more developed and technologically modern industrial equipment so as to stay on the top.
To get some advice or order, phone us or write to the online chat on our site. You can also forward a list of the necessary equipment to the email of firm - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
OUT | Monitoring output (semiconductor) |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | UB | Power supply, DC 24 V | BN | |
2 | FO1A | Safety output, channel 1 | WH | |
3 | 0V | Ground, DC 0 V | BU | |
4 | FO1B | Safety output, channel 2 | BK | |
5 | OUT | Monitoring output | GY |
Housing material | Plastic, PBT |
Weight | |
Net | 0,06 kg |
Ambient temperature | |
Cable static | -25 ... 65 °C |
Cable dynamic | -5 ... 65 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.400 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.1 Nm |
Ready delay | 0,5 s |
Switching frequency | max.1 Hz |
Connection | Connection cable PUR 0.2m with plug connector M12 5-pin |
Bending radius | |
static | 5 x cable diameter |
Dynamic | 10 x cable diameter |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5 % |
Current consumption | max.30 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.300 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | max.260 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs OA/OB | |
Test pulses | max.0,3 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 150 mA |
Output voltage | |
HIGH U(OA) / U(OB) | UB-1,5V ... UB V DC |
LOW U(OA) / U(OB) | 0 ... 1 V DC |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 1.8 x 10-9 |
Mission time | 20 |
Switch-on distance | 19 mm |
Assured switch-off distance Sar | |
In x/z direction | max.40 mm |
In y direction | max.60 mm |
Assured operating distance Sao | min.14 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 15 mm |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Assured operating distance Sao | min.10 mm |
Switching hysteresis | min.1 mm |