CES-AP-CR2-AH-SB-106552 Euchner 106552
 CES-AP-CR2-AH-SB-106552 Euchner 106552

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

CES-AP-CR2-AH-SB-106552 106552 Euchner

Manufacturer

Euchner

Country

Germany

Name

CES-AP-CR2-AH-SB-106552

Part number

106552

Description

CES-AP-CR2-AH-SB

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications CES-AP-CR2-AH-SB-106552 106552

If you are seeking Euchner CES-AP-CR2-AH-SB-106552 106552, contact FAMAGA, the world's central supplier of manufacturing equipment. Our company has functioned for more than ten years - these are years of experience, which are portrayed in the quality of outputs and particular attention to each purchaser. We appreciate everyone, who cooperated with us - hence, our regular purchasers procure the most favorable purchase conditions and discounts on the manufacturing equipment market. Today, there are more than 4500 such clients, and we constantly make new agreements. More than 750 affairs are settled per day, because FAMAGA supplies all over the world . A well-built logistics system and a partnership network guide us to ship our goods anywhere in the earth quickly without damaging product quality.

A particular source of good name for FAMAGA is its team members, each of whom contributes to common cause. We call into our team only experts, who already have experience in the field of machine made streamlined equipment.

All products from FAMAGA are affirmed - we are responsible for the aftereffect of our work. At the moment, more than 10 million units of products have been provided, and this quantity is amounting every day. We are glad that customers choose FAMAGA again and again, and we are happy to make more progressive and technologically developed industrial equipment so as keep on top of it.

To inquire or make a request, get in touch with us or send a message to the online chat on our site. You can also send a list of the needful equipment to the email of organization - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.

Features CES-AP-CR2-AH-SB-106552 106552

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Door hinge right
  • Category 4/PL e according to EN ISO 13849-1
  • Connection cable PUR, 0.2 m, plug connector M12, 5-core
  • Unicode
  • Two safety screws M4x14 included
Short circuit monitoring The switch generates its own clock signal on the output cables OA/OB. Pay attention to this aspect when connecting to control systems and relays. Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostics LED
Additional connection
OUTMonitoring output (semiconductor)
Approach directions Typical operating distance (Actuator CES-A-BLN... in conjunction with safety switch CES-AP-C.2-... in case of mounting on plastic) For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the operating distance of the side lobes is not entered. Attention: The operating distance may vary depending on the background material and installation situation. Connector assignment
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connection cable
1 UB Power supply, DC 24 V BN
2 FO1A Safety output, channel 1 WH
3 0V Ground, DC 0 V BU
4 FO1B Safety output, channel 2 BK
5 OUT Monitoring output GY
Housing material Plastic, PBT
Weight
Net 0,06 kg
Ambient temperature
Cable dynamic -5 ... 65 °C
Cable static -25 ... 65 °C
Degree of protection IP67
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting method Surface mounting on metal
Mounting distance
Between 2 switches or 2 actuators min.400 mm
Installation orientation Any
Tightening torque
Fixing screws max.1 Nm
Ready delay 0,5 s
Switching frequency max.1 Hz
Connection Connection cable PUR 0.2m with plug connector M12 5-pin
Bending radius
static 5 x cable diameter
Dynamic 10 x cable diameter
Electrical connection ratings
Operating voltage DC
UB 24 V DC 15% ... 15% Regulated, residual ripple < 5 %
Current consumption max.30 mA
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.300 ms
Safety class III
Risk time according to EN 60947-5-3 max.260 ms
Monitoring output OUT
Type of output p-switching, short circuit-proof
Switching current max.50 mA
Output voltage 0,8 x UB ... UB V DC
Safety outputs OA/OB
Test pulses max.0,3 ms
Test-pulse interval min.100 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 150 mA
Output voltage
LOW U(OA) / U(OB) 0 ... 1 V DC
HIGH U(OA) / U(OB) UB-1,5V ... UB V DC
Rated conditional short-circuit current 100 A
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Work area
Repeat accuracy R ? 10
Other
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 1.8 x 10-9
Mission time 20
In combination with Actuator CES-A-BDN-06-104730Operating distance
Switch-on distance 19 mm
Assured switch-off distance Sar
In x/z direction max.40 mm
In y direction max.60 mm
Assured operating distance Sao min.14 mm
Switching hysteresis min.1 mm
In combination with Actuator CES-A-BLN-R2-100776, CES-A-BLN-U2-103450, CES-A-BLN-L2-104510, CES-A-BLN-U2-112710Operating distance
Switch-on distance 15 mm
Assured switch-off distance Sar
In y direction max.60 mm
In x/z direction max.40 mm
Assured operating distance Sao min.10 mm
Switching hysteresis min.1 mm