CES-AP-CR2-CH-SB-106550 Euchner 106550
 CES-AP-CR2-CH-SB-106550 Euchner 106550

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

CES-AP-CR2-CH-SB-106550 106550 Euchner

Manufacturer

Euchner

Country

Germany

Name

CES-AP-CR2-CH-SB-106550

Part number

106550

Description

Schalter CES-AP CES-AP-CR2-CH-SB-106550

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications CES-AP-CR2-CH-SB-106550 106550

If you are looking for Euchner CES-AP-CR2-CH-SB-106550 106550, call FAMAGA, the world's chief company of manufacturing equipment. Our company has advanced for more than ten years - these are ages of experience, which are illustrated in the quality of outcomes and personalseparate attention to each customer. We respect everyone, who collaborated with us - so, our regular customers pick up the most beneficial purchase terms and discounts on the factory-made equipment market. At this time, there are more than 4 thousand such customers, and we constantly form new agreements. More than 700 purchases are terminated per day, because FAMAGA works all over the planet . A well-elaborated logistics chains and a partnership network help us to deliver our units anywhere in the planet with no delay without compromising product quality.

A particular source of honor for FAMAGA is its employees, each of whom contributes to common cause. We invite into our team only professionals, who already have experience in the sphere of manufacturing equipment.

All outcomes from FAMAGA are assured - we are responsible for the result of our work. Now, more than 10 million units of products have been supplied, and this amount is growing every day. We are happy that purchasers choose FAMAGA again and again, and we are eager to make more developed and technologically innovative industrial equipment so as stay in control.

To ask a question or order, phone us or write a message to the online chat on our site. You can also direct a list of the necessary equipment to the email of corporation - we will contact you ourselves with a worked out commercial proposal from FAMAGA.

Features CES-AP-CR2-CH-SB-106550 106550

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Door hinge right
  • Category 4/PL e according to EN ISO 13849-1
  • Connection cable PUR, 0.2 m, plug connector M12, 5-core
  • Multicode
  • Two safety screws M4x14 included
Short circuit monitoring The switch generates its own clock signal on the output cables OA/OB. Pay attention to this aspect when connecting to control systems and relays. Multicode evaluation Every suitable actuator is detected by the switch. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostics LED
Additional connection
OUTMonitoring output (semiconductor)
Approach directions Typical operating distance (Actuator CES-A-BLN... in conjunction with safety switch CES-AP-C.2-... in case of mounting on plastic) For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the operating distance of the side lobes is not entered. Attention: The operating distance may vary depending on the background material and installation situation. Connector assignment
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connection cable
1 UB Power supply, DC 24 V BN
2 FO1A Safety output, channel 1 WH
3 0V Ground, DC 0 V BU
4 FO1B Safety output, channel 2 BK
5 OUT Monitoring output GY
Housing material Plastic, PBT
Weight
Net 0,06 kg
Ambient temperature
Cable static -25 ... 65 °C
Cable dynamic -5 ... 65 °C
Degree of protection IP67
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting method Surface mounting on metal
Mounting distance
Between 2 switches or 2 actuators min.400 mm
Installation orientation Any
Tightening torque
Fixing screws max.1 Nm
Ready delay 0,5 s
Switching frequency max.1 Hz
Connection Connection cable PUR 0.2m with plug connector M12 5-pin
Bending radius
static 5 x cable diameter
Dynamic 10 x cable diameter
Electrical connection ratings
Operating voltage DC
UB 24 V DC 15% ... 15% Regulated, residual ripple < 5 %
Current consumption max.30 mA
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.300 ms
Safety class III
Risk time according to EN 60947-5-3 max.260 ms
Monitoring output OUT
Type of output p-switching, short circuit-proof
Switching current max.50 mA
Output voltage 0,8 x UB ... UB V DC
Safety outputs OA/OB
Test pulses max.0,3 ms
Test-pulse interval min.100 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 150 mA
Output voltage
HIGH U(OA) / U(OB) UB-1,5V ... UB V DC
LOW U(OA) / U(OB) 0 ... 1 V DC
Rated conditional short-circuit current 100 A
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Work area
Repeat accuracy R ? 10
Other
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 1.8 x 10-9
Mission time 20
In combination with Actuator CES-A-BLN-R2-100776, CES-A-BLN-U2-103450, CES-A-BLN-L2-104510, CES-A-BLN-U2-112710Operating distance
Switch-on distance 15 mm
Assured switch-off distance Sar
In x/z direction max.40 mm
In y direction max.60 mm
Assured operating distance Sao min.10 mm
Switching hysteresis min.1 mm
In combination with Actuator CES-A-BDN-06-104730Operating distance
Switch-on distance 19 mm
Assured switch-off distance Sar
In x/z direction max.40 mm
In y direction max.60 mm
Assured operating distance Sao min.14 mm
Switching hysteresis min.1 mm