Specifications CES-AP-CR2-AH-L20-106195 106195

If you are pursuing Euchner CES-AP-CR2-AH-L20-106195 106195, call FAMAGA, the world's principle retailer of machine made equipment. Our company has advanced for more than ten years - these are ages of experience, which are outlined in the quality of outcomes and private attention to each customer. We value everyone, who engaged with us - so, our regular consumers bring in the most attractive purchase forms and discounts on the factory-made equipment market. At this time, there are more than 4 thousand such buyers, and we constantly form new agreements. More than 600 proceedings are resolved per day, because FAMAGA works all over the planet . A well-developed logistics link and a partnership network let us to dispatch our products anywhere in the planet quickly without disreputing product quality.

A special source of honor for FAMAGA is its employees, each of whom contributes to common cause. We request into our team only professionals, who already have experience in the sphere of manufacturing equipment.

All merchandises from FAMAGA are verified - we are responsible for the result of our work. Now, more than 10 million units of products have been delivered, and this amount is ascending every day. We are happy that buyers choose FAMAGA again and again, and we strive to make more developed and technologically modern industrial equipment so as to stay on the top.

To ask a question or order, phone us or write a message to the online chat on our site. You can also direct a list of the necessary equipment to the email of firm - we will contact you ourselves with a prepared commercial proposal from FAMAGA.

Features CES-AP-CR2-AH-L20-106195 106195

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Door hinge right
  • Category 4/PL e according to EN ISO 13849-1
  • Connection cable PVC, 20 m, flying lead, 6-core
  • Unicode
  • Two safety screws M4x14 included
Short circuit monitoring The switch generates its own clock signal on the output cables OA/OB. Pay attention to this aspect when connecting to control systems and relays. Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostics LED
Additional connection
OUTMonitoring output (semiconductor)
Approach directions Typical operating distance (Actuator CES-A-BLN... in conjunction with safety switch CES-AP-C.2-... in case of mounting on plastic) For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the operating distance of the side lobes is not entered. Attention: The operating distance may vary depending on the background material and installation situation. Terminal assignment
Designation Function Conductor coloring of connection cable
UB Power supply, DC 24 V BN
FO1A Safety output, channel 1 WH
0V Ground, DC 0 V BU
FO1B Safety output, channel 2 BK
OUT Monitoring output GY
- n.c. PK
Housing material Plastic, PBT
Weight
Net 0,73 kg
Ambient temperature
Cable static -40 ... 65 °C
Cable dynamic 0 ... 65 °C
Degree of protection IP67, IP69K
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting method Surface mounting on metal
Mounting distance
Between 2 switches or 2 actuators min.400 mm
Installation orientation Any
Tightening torque
Fixing screws max.1 Nm
Ready delay 0,5 s
Switching frequency max.1 Hz
Connection connection cable PVC, length 20m
Bending radius
static 5 x cable diameter
Dynamic 10 x cable diameter
Electrical connection ratings
Operating voltage DC
UB 24 V DC 15% ... 15% Regulated, residual ripple < 5 %
Current consumption max.30 mA
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.300 ms
Safety class III
Risk time according to EN 60947-5-3 max.260 ms
Monitoring output OUT
Type of output p-switching, short circuit-proof
Switching current max.50 mA
Output voltage 0,8 x UB ... UB V DC
Safety outputs OA/OB
Test pulses max.0,3 ms
Test-pulse interval min.100 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 150 mA
Output voltage
HIGH U(OA) / U(OB) UB-1,5V ... UB V DC
LOW U(OA) / U(OB) 0 ... 1 V DC
Rated conditional short-circuit current 100 A
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Work area
Repeat accuracy R ? 10
Other
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 1.8 x 10-9
Mission time 20
In combination with Actuator CES-A-BDN-06-104730Operating distance
Switch-on distance 19 mm
Assured switch-off distance Sar
In y direction max.60 mm
In x/z direction max.40 mm
Assured operating distance Sao min.14 mm
Switching hysteresis min.1 mm
In combination with Actuator CES-A-BLN-R2-100776, CES-A-BLN-U2-103450, CES-A-BLN-L2-104510, CES-A-BLN-U2-112710Operating distance
Switch-on distance 15 mm
Assured switch-off distance Sar
In y direction max.60 mm
In x/z direction max.40 mm
Assured operating distance Sao min.10 mm