We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are pursuing Euchner CES-AP-CR2-AH-L20-106195 106195, call FAMAGA, the world's principle retailer of machine made equipment. Our company has advanced for more than ten years - these are ages of experience, which are outlined in the quality of outcomes and private attention to each customer. We value everyone, who engaged with us - so, our regular consumers bring in the most attractive purchase forms and discounts on the factory-made equipment market. At this time, there are more than 4 thousand such buyers, and we constantly form new agreements. More than 600 proceedings are resolved per day, because FAMAGA works all over the planet Germany, United Kingdom, Peru, Botswana, Slovenia, Armenia, Estonia, Bahamas, Belarus, Kiribati, South Korea, Ukraine, Djibouti, Oman, Iraq, Guyana, Pakistan, The Bahamas, Australia, Chile, Argentina, Albania, Tanzania, Netherlands, Syria, Latvia, Czech Republic, Haiti, Benin, Kuwait, Burkina Faso, Serbia, Antigua and Barbuda, Seychelles, Tajikistan, Angola, Ghana, Mauritius, Poland, Comoros, Zimbabwe, Guatemala, Qatar. A well-developed logistics link and a partnership network let us to dispatch our products anywhere in the planet quickly without disreputing product quality.
A special source of honor for FAMAGA is its employees, each of whom contributes to common cause. We request into our team only professionals, who already have experience in the sphere of manufacturing equipment.
All merchandises from FAMAGA are verified - we are responsible for the result of our work. Now, more than 10 million units of products have been delivered, and this amount is ascending every day. We are happy that buyers choose FAMAGA again and again, and we strive to make more developed and technologically modern industrial equipment so as to stay on the top.
To ask a question or order, phone us or write a message to the online chat on our site. You can also direct a list of the necessary equipment to the email of firm - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
OUT | Monitoring output (semiconductor) |
Designation | Function | Conductor coloring of connection cable |
---|---|---|
UB | Power supply, DC 24 V | BN |
FO1A | Safety output, channel 1 | WH |
0V | Ground, DC 0 V | BU |
FO1B | Safety output, channel 2 | BK |
OUT | Monitoring output | GY |
- | n.c. | PK |
Housing material | Plastic, PBT |
Weight | |
Net | 0,73 kg |
Ambient temperature | |
Cable static | -40 ... 65 °C |
Cable dynamic | 0 ... 65 °C |
Degree of protection | IP67, IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.400 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.1 Nm |
Ready delay | 0,5 s |
Switching frequency | max.1 Hz |
Connection | connection cable PVC, length 20m |
Bending radius | |
static | 5 x cable diameter |
Dynamic | 10 x cable diameter |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5 % |
Current consumption | max.30 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.300 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | max.260 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs OA/OB | |
Test pulses | max.0,3 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 150 mA |
Output voltage | |
HIGH U(OA) / U(OB) | UB-1,5V ... UB V DC |
LOW U(OA) / U(OB) | 0 ... 1 V DC |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 1.8 x 10-9 |
Mission time | 20 |
Switch-on distance | 19 mm |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Assured operating distance Sao | min.14 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 15 mm |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Assured operating distance Sao | min.10 mm |
Switching hysteresis | min.1 mm |