We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are questing Euchner CES-AP-CL2-CH-L20-106194 106194, make contact with FAMAGA, the world's primary vendor of manufacturing equipment. Our company has functioned for more than ten years - these are ages of experience, which are portrayed in the quality of outputs and personalseparate attention to each purchaser. We praise everyone, who conspired with us - hence, our regular customers procure the most desirable purchase conditions and discounts on the manufacturing equipment market. At this moment, there are more than 4500 such purchasers, and we constantly arrange new agreements. More than 750 transactions are made per day, because FAMAGA supplies all over the globe Germany, United Kingdom, Laos, Namibia, Belgium, Estonia, Nigeria, Myanmar, Hungary, China, Rwanda, Togo, Kiribati, Bhutan, Zimbabwe, Turkmenistan, Mali, Uzbekistan, Morocco, Belarus, United States, Zambia, Vietnam, Chad, Bangladesh, Ghana, Seychelles, Iraq, Argentina, Iran, Israel, Mongolia, Georgia, Libya, Bosnia and Herzegovina, Jordan, Madagascar, Equatorial Guinea, Kyrgyzstan, Paraguay, Sierra Leone, Niger, Andorra. A well-shaped logistics connection and a partnership network allow us to deliver our items anywhere in the earth with no delay without compromising product quality.
A specific source of repute for FAMAGA is its personnel, each of whom contributes to common cause. We accept into our team only specialists, who already have experience in the range of machine made streamlined equipment.
All spare parts from FAMAGA are guaranteed - we are responsible for the aftereffect of our work. Nowadays, more than 10 million units of products have been provided, and this quantity is growing every day. We are glad that consumers choose FAMAGA again and again, and we are glad to make more progressive and technologically developed industrial equipment so as keep on top of it.
To request or make a request, get in touch with us or write to the online chat on our site. You can also dispatch a list of the needful equipment to the email of organization - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
OUT | Monitoring output (semiconductor) |
Designation | Function | Conductor coloring of connection cable |
---|---|---|
UB | Power supply, DC 24 V | BN |
FO1A | Safety output, channel 1 | WH |
0V | Ground, DC 0 V | BU |
FO1B | Safety output, channel 2 | BK |
OUT | Monitoring output | GY |
- | n.c. | PK |
Housing material | Plastic, PBT |
Weight | |
Net | 0,73 kg |
Ambient temperature | |
Cable dynamic | 0 ... 65 °C |
Cable static | -40 ... 65 °C |
Degree of protection | IP67, IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.400 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.1 Nm |
Ready delay | 0,5 s |
Switching frequency | max.1 Hz |
Connection | connection cable PVC, length 20m |
Bending radius | |
static | 5 x cable diameter |
Dynamic | 10 x cable diameter |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5 % |
Current consumption | max.30 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.300 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | max.260 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs OA/OB | |
Test pulses | max.0,3 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 150 mA |
Output voltage | |
HIGH U(OA) / U(OB) | UB-1,5V ... UB V DC |
LOW U(OA) / U(OB) | 0 ... 1 V DC |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 1.8 x 10-9 |
Mission time | 20 |
Switch-on distance | 15 mm |
Assured switch-off distance Sar | |
In x/z direction | max.40 mm |
In y direction | max.60 mm |
Assured operating distance Sao | min.10 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 19 mm |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Assured operating distance Sao | min.14 mm |
Switching hysteresis | min.1 mm |