Specifications CES-AP-CL2-AH-L10-106192 106192

If you are seeking Euchner CES-AP-CL2-AH-L10-106192 106192, get in touch with FAMAGA, the world's dominant provider of mechanized equipment. Our company has worked for more than ten years - these are years of experience, which are symbolized in the quality of items and particular attention to each buyer. We respect everyone, who worked with us - so, our regular purchasers get the most flexible purchase terms and discounts on the factory-made equipment market. Today, there are more than 4 thousand such clients, and we constantly sign new agreements. More than 600 affairs are settled per day, because FAMAGA works all over the globe . A well-elaborated logistics chains and a partnership network guide us to ship our goods anywhere in the planet immediately without damaging product quality.

A particular source of good name for FAMAGA is its staff members, each of whom contributes to common cause. We call into our team only experts, who already have experience in the range of manufacturing equipment.

All items from FAMAGA are affirmed - we are responsible for the result of our work. Nowadays, more than 10 million units of products have been delivered, and this amount is amounting every day. We are happy that customers choose FAMAGA again and again, and we are eager to make more developed and technologically modern industrial equipment so as to stay on the top.

To inquire or order, phone us or send a message to the online chat on our site. You can also dispatch a list of the necessary equipment to the email of firm - we will contact you ourselves with a prepared commercial proposal from FAMAGA.

Features CES-AP-CL2-AH-L10-106192 106192

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Door hinge left
  • Category 4/PL e according to EN ISO 13849-1
  • Connection cable PVC, 10 m, flying lead, 6-core
  • Unicode
  • Two safety screws M4x14 included
Short circuit monitoring The switch generates its own clock signal on the output cables OA/OB. Pay attention to this aspect when connecting to control systems and relays. Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostics LED
Additional connection
OUTMonitoring output (semiconductor)
Approach directions Typical operating distance (Actuator CES-A-BLN... in conjunction with safety switch CES-AP-C.2-... in case of mounting on plastic) For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the operating distance of the side lobes is not entered. Attention: The operating distance may vary depending on the background material and installation situation. Terminal assignment
Designation Function Conductor coloring of connection cable
UB Power supply, DC 24 V BN
FO1A Safety output, channel 1 WH
0V Ground, DC 0 V BU
FO1B Safety output, channel 2 BK
OUT Monitoring output GY
- n.c. PK
Housing material Plastic, PBT
Weight
Net 0,39 kg
Ambient temperature
Cable static -40 ... 65 °C
Cable dynamic 0 ... 65 °C
Degree of protection IP67, IP69K
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting method Surface mounting on metal
Mounting distance
Between 2 switches or 2 actuators min.400 mm
Installation orientation Any
Tightening torque
Fixing screws max.1 Nm
Ready delay 0,5 s
Switching frequency max.1 Hz
Connection connection cable PVC, length 10m
Bending radius
static 5 x cable diameter
Dynamic 10 x cable diameter
Electrical connection ratings
Operating voltage DC
UB 24 V DC 15% ... 15% Regulated, residual ripple < 5 %
Current consumption max.30 mA
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.300 ms
Safety class III
Risk time according to EN 60947-5-3 max.260 ms
Monitoring output OUT
Type of output p-switching, short circuit-proof
Switching current max.50 mA
Output voltage 0,8 x UB ... UB V DC
Safety outputs OA/OB
Test pulses max.0,3 ms
Test-pulse interval min.100 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 150 mA
Output voltage
HIGH U(OA) / U(OB) UB-1,5V ... UB V DC
LOW U(OA) / U(OB) 0 ... 1 V DC
Rated conditional short-circuit current 100 A
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Work area
Repeat accuracy R ? 10
Other
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 1.8 x 10-9
Mission time 20
In combination with Actuator CES-A-BDN-06-104730Operating distance
Switch-on distance 19 mm
Assured switch-off distance Sar
In x/z direction max.40 mm
In y direction max.60 mm
Assured operating distance Sao min.14 mm
Switching hysteresis min.1 mm
In combination with Actuator CES-A-BLN-R2-100776, CES-A-BLN-U2-103450, CES-A-BLN-L2-104510, CES-A-BLN-U2-112710Operating distance
Switch-on distance 15 mm
Assured switch-off distance Sar
In x/z direction max.40 mm
In y direction max.60 mm
Assured operating distance Sao min.10 mm