We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CES-AR-CR2-AH-SG-105751
Part number
105751
Description
Sicherheitsschalter
Stock availability:
On request
If you are inspecting Euchner CES-AR-CR2-AH-SG-105751 105751, communicate with FAMAGA, the world's principle provider of mechanized equipment. Our company has lasted for more than ten years - these are ages of experience, which are portrayed in the quality of outcomes and particular attention to each consumer. We cherish everyone, who engaged with us - so, our regular purchasers obtain the most helpful purchase forms and discounts on the factory-made equipment market. Nowadays, there are more than 4500 such clients, and we constantly arrange new agreements. More than 600 agreements are achieved per day, because FAMAGA supplies all over the earth Germany, United Kingdom, Niger, Rwanda, Benin, Argentina, Ghana, Pakistan, Bulgaria, Finland, Greece, Liechtenstein, Saudi Arabia, Israel, Tunisia, Zimbabwe, Latvia, Mozambique, Slovakia, Serbia, Liberia, South Sudan, Uruguay, Swaziland, Burundi, Kyrgyzstan, Algeria, Montenegro, Brazil, Vietnam, Thailand, Malaysia, Eswatini, Sweden, Cameroon, Senegal, Iran, Cyprus, Paraguay, India. A well-shaped logistics chains and a partnership network cheer us to conduct our products anywhere in the earth with no delay without damaging product quality.
A specific source of good name for FAMAGA is its personnel, each of whom contributes to common cause. We call into our team only specialists, who already have experience in the direction of machine made streamlined equipment.
All items from FAMAGA are affirmed - we are responsible for the aftereffect of our work. At this moment, more than 10 million units of products have been provided, and this amount is amounting every day. We are glad that buyers choose FAMAGA again and again, and we are glad to make more developed and technologically advanced industrial equipment so as keep on top of it.
To inquire or make a request, phone us or write a message to the online chat on our site. You can also forward a list of the needful equipment to the email of firm - we will contact you ourselves with a made commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
OUT | Monitoring output (semiconductor) |
RST | Reset input |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | IB | Enable input for channel 2 | WH | |
2 | UB | Power supply, DC 24 V | BN | |
3 | OA | Safety output, channel 1 | GN | |
4 | OB | Safety output, channel 2 | YE | |
5 | OUT | Monitoring output | GY | |
6 | IA | Enable input for channel 1 | PK | |
7 | 0V | Ground, DC 0 V | BU | |
8 | RST | Reset input | RD |
Housing material | Plastic, PBT |
Weight | |
Net | 0,04 kg |
Ambient temperature | -25 ... 65 °C |
Degree of protection | IP67, IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.120 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.1 Nm |
Ready delay | 10 s |
Switching frequency | max.1 Hz |
Connection | M8 plug connector, 8-pin |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5 % |
Current consumption | max.50 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs OA/OB | |
Test pulses | max.1 ms |
Test-pulse interval | min.140 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 200 mA |
Output voltage | |
HIGH U(OA) / U(OB) | UB-1,5V ... UB V DC |
LOW U(OA) / U(OB) | 0 ... 1 V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 1.9 x 10-9 |
Mission time | 20 |
Switch-on distance | 15 mm |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Assured operating distance Sao | min.10 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 19 mm |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Assured operating distance Sao | min.14 mm |
Switching hysteresis | min.1 mm |