We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are looking for Euchner CES-AR-CR2-AH-SA-105746 105746, connect FAMAGA, the world's prime supplier of industrialized equipment. Our company has worked for more than ten years - these are ages of experience, which are illustrated in the quality of outcomes and personalseparate attention to each buyer. We understand everyone, who conspired with us - so, our regular customers get the most convenient purchase forms and discounts on the factory-made equipment market. At present, there are more than 4500 such buyers, and we constantly compose new agreements. More than 600 purchases are terminated per day, because FAMAGA supplies all over the world Germany, United Kingdom, Chile, Czech Republic, Ireland, Brazil, Bulgaria, Benin, Turkey, Pakistan, Namibia, Ecuador, Liberia, Kyrgyzstan, Malta, Burma, Indonesia, Comoros, Hungary, Albania, Uzbekistan, El Salvador, Uganda, Nepal, Antigua and Barbuda, Libya, Sierra Leone, Senegal, Slovakia, Bolivia, Australia, Cyprus, Norway, Syria, North Korea, Thailand, New Zealand, United Arab Emirates, Kazakhstan, Nigeria. A advanced logistics system and a partnership network assist us to send our items anywhere in the globe immediately without compromising product quality.
A particular source of honor for FAMAGA is its workers, each of whom contributes to common cause. We accept into our team only experts, who already have experience in the field of factory-made equipment.
All products from FAMAGA are guaranteed - we are responsible for the aftereffect of our work. At the moment, more than 10 million units of products have been supplied, and this amount is growing every day. We are glad that consumers choose FAMAGA again and again, and we are pleased to make more developed and technologically advanced industrial equipment so as keep on top of it.
To ask a question or book, phone us or write to the online chat on our site. You can also send a list of the desirable equipment to the email of firm - we will contact you ourselves with a made commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
OUT | Monitoring output (semiconductor) |
RST | Reset input |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | IB | Enable input for channel 2 | WH | |
2 | UB | Power supply, DC 24 V | BN | |
3 | OA | Safety output, channel 1 | GN | |
4 | OB | Safety output, channel 2 | YE | |
5 | OUT | Monitoring output | GY | |
6 | IA | Enable input for channel 1 | PK | |
7 | 0V | Ground, DC 0 V | BU | |
8 | RST | Reset input | RD |
Housing material | Plastic, PBT |
Weight | |
Net | 0,09 kg |
Ambient temperature | |
Cable dynamic | -25 ... 65 °C |
Cable static | -25 ... 65 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.120 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.1 Nm |
Ready delay | 10 s |
Switching frequency | max.1 Hz |
Connection | Connection cable PUR, length 1m with plug connector M12 8-pin |
Bending radius | |
static | 5 x cable diameter |
Dynamic | 10 x cable diameter |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5 % |
Current consumption | max.50 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs OA/OB | |
Test pulses | max.1 ms |
Test-pulse interval | min.140 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 200 mA |
Output voltage | |
LOW U(OA) / U(OB) | 0 ... 1 V DC |
HIGH U(OA) / U(OB) | UB-1,5V ... UB V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 1.9 x 10-9 |
Mission time | 20 |
Switch-on distance | 19 mm |
Assured switch-off distance Sar | |
In x/z direction | max.40 mm |
In y direction | max.60 mm |
Assured operating distance Sao | min.14 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 15 mm |
Assured switch-off distance Sar | |
In x/z direction | max.40 mm |
In y direction | max.60 mm |
Assured operating distance Sao | min.10 mm |
Switching hysteresis | min.1 mm |