We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are seeking Euchner CES-AP-CR2-AH-SF-105295 105295, catch up with FAMAGA, the world's principle company of factory-made equipment. Our company has advanced for more than ten years - these are ages of experience, which are symbolized in the quality of spare parts and private attention to each customer. We esteem everyone, who engaged with us - thus, our regular consumers bring in the most beneficial purchase forms and discounts on the machine made streamlined equipment market. Now, there are more than 4 thousand such consumers, and we constantly sign new agreements. More than 700 contracts are concluded per day, because FAMAGA works all over the planet Germany, United Kingdom, Latvia, Swaziland, Libya, Comoros, Syria, Cuba, Kyrgyzstan, Mauritius, Israel, Poland, Qatar, Yemen, Togo, Guyana, Uganda, Iran, Madagascar, Slovakia, Denmark, Monaco, Iraq, Vietnam, Kuwait, Jamaica, East Timor, Afghanistan, Zambia, Zimbabwe, Armenia, Peru, The Gambia, Djibouti, Costa Rica, Tajikistan, Iceland, Suriname, United States. A well-elaborated logistics network and a partnership network help us to ship our products anywhere in the planet on-time without disreputing product quality.
A special source of dignity for FAMAGA is its staff members, each of whom contributes to our work. We request into our team only professionals, who already have experience in the sphere of manufacturing equipment.
All outcomes from FAMAGA are verified - we are responsible for the result of our work. Now, more than 10 million units of products have been delivered, and this bulk is ascending every day. We are happy that buyers choose FAMAGA again and again, and we are eager to make more exceptional and technologically innovative industrial equipment so as to stay on the top.
To get some advice or order, contact us or send a message to the online chat on our site. You can also direct a list of the necessary equipment to the email of corporation - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
OUT | Monitoring output (semiconductor) |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | UB | Power supply, DC 24 V | BN | |
2 | FO1A | Safety output, channel 1 | WH | |
3 | 0V | Ground, DC 0 V | BU | |
4 | FO1B | Safety output, channel 2 | BK | |
5 | OUT | Monitoring output | GY | |
6 | - | n.c. | PK |
Housing material | Plastic, PBT |
Weight | |
Net | 0,04 kg |
Ambient temperature | -30 ... 65 °C |
Degree of protection | IP67, IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.400 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.1 Nm |
Ready delay | 0,5 s |
Switching frequency | max.1 Hz |
Connection | Plug connector with latching connection, O8, 6-pin |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5 % |
Current consumption | max.30 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.300 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | max.260 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs OA/OB | |
Test pulses | max.0,3 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 150 mA |
Output voltage | |
HIGH U(OA) / U(OB) | UB-1,5V ... UB V DC |
LOW U(OA) / U(OB) | 0 ... 1 V DC |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 1.8 x 10-9 |
Mission time | 20 |
Switch-on distance | 15 mm |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Assured operating distance Sao | min.10 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 19 mm |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Assured operating distance Sao | min.14 mm |
Switching hysteresis | min.1 mm |